Contamination of heavy metals in the environment is a burning and contemporary issue of modern life. Whilst lead contamination is historic, the ongoing extensive use of lead in batteries is likely to continue to cause serious environmental problems. Silver ions also present multiple environmental issues, such as bioaccumulation and toxicity. As a result, these two heavy metal ions have a high impact from an environmental and industrial point of view. Thus, the colorimetric and fluorescence detection of these two metal ions has been the subject of intense research during the last decade and pyrene-based fluorophores have played a crucial role in their detection. This review article summarizes the recent chronological progress on pyrene moiety integrated small molecule chemosensors for the colorimetric and fluorescent detection of silver and lead ions. Herein, the different strategies that have been utilized for the recognition of lead and silver ions are discussed. Throughout, the juxtaposition of structural aspects of the chemosensors and their sensitivity has been scrutinized together with an overview and future vision.
Though fluorescent chemosensors might be composed of various signalling moieties like BODIPY, indolylmethanes, carbohydrate-derived macrocyclic compounds, coumarin, cyanine, cucurbituril, naphthalene diimides, nitrobenzoxadiazole, calix[4]arene, calixarenes, pillar[n]arene, DNA-based sensors, porphyrins, etc., pyrene holds some additional advantages, particularly in the context of fluorescence imaging. Basically, pyrene units are involved in aggregation. Within different micro-environments such as encapsulation within protein entities, surfactants, molecular cavities etc., the aggregation behavior is significantly disturbed. Consequently, the switching of excimeric to monomeric emission is a very natural and common strategy to monitor any analyte in vitro or in vivo. This makes pyrene derivatives highly desirable for bioimaging application which is one of the principal attractions of pyrene-based fluorophores. Additionally, pyrene is generally photostable under standard conditions, making it a reliable fluorescent marker in long-term experiments and applications. Since the fluorescence properties of pyrenes are susceptible to the surrounding solvent environment, they can also be employed to probe the polarity and microenvironment of the solvent or host matrix. These unique and versatile photophysical features of pyrene-based fluorophores attracted us to write a review article on their application in the fluorescence detection of heavy metal ions.19
In addition, pyrene is well known for its aggregation properties at the solution phase or solid state. Naturally, it is quite easy to expect that pyrene might cause either aggregation-induced emission (AIE) or aggregation-induced enhanced emission (AIEE) or aggregation-caused quenching (ACQ) upon preferential binding with an analyte. Also, polycyclic aromatic hydrocarbons like pyrene are highly electron deficient and pyrene derivatives containing an electron donor centre either conjugated or non-conjugated to the core might be involved in intramolecular charge transfer (ICT) or photoinduced electron transfer (PET) and even the Forster resonance energy transfer (FRET) process. Now, if any foreign analyte could selectively induce or tune either of these photophysical events, that particular foreign analyte could be recognized spectroscopically. This is one of the extensively utilized strategies of pyrene-based fluorophores. Besides, attachment of any hydrogen bond or proton acceptor centre or hydrogen bond or proton donor centre that might be involved in hydrogen bonding or proton transfer with a foreign analyte selectively might alter the photophysical properties of the pyrene derivative. In addition, the presence of multiple electron donor centres within a pyrene derivative might cause chelation enhanced quenching (CHEQ) or ligand to metal change transfer (LMCT) or metal to ligand charge transfer (MLCT) upon preferential binding with a particular metal ion. Naturally, there is a huge scope for pyrene derivatives to involve diverse photoprocesses in the fluorescence detection of diverse analytes of importance. During the discussion, we will find that different pyrene derivatives involve diverse photoprocesses in the detection of toxic cations like Ag+ and Pb2+.19
Herein, our concern is the detection of two heavy metal ions, Ag+ and Pb2+, from metals that have been used since Roman times and are closely associated as they were both mined from the same lead minerals galena (PbS) and lead carbonate. Heavy metals are mostly toxic even when present at very low concentrations. Despite this, heavy metals have a few positive effects like key roles in metabolism, catalysis and biomineralization, and some negative effects as a result of their high toxicity, causing serious health and environmental hazards.20,21 Interestingly, various salts of Ag+ (silver nitrate, silver acetate, silver proteinate and silver sulphadiazine) can play a role in glycolysis, particularly in the production of lactate and pyruvate. Also, Ag+ has an important role in copper metabolism.22,23 On the other hand, lead is widely used in the dye industry, gasoline and batteries and readily contaminates the environment, particularly soil and groundwater. Subsequently, it enters into the food chain and accumulates in biological cells and tissues.24,25
In spite of being used as a component of jewellery, ornaments and currency coins for millennia, silver has also been widely used in making utensils due to its bactericidal and disinfectant activities, in photography and in the electrical industry due to its high conductivity.26–29 In addition, the minerals of silver (as Ag+ salts) exist in the Earth's crust and contaminate the environment due to mining activities and natural weathering. Contamination of Ag+ salts in the environment also occurs due to the extensive use of Ag+ salts in catalysts, electroplating, photography and medical devices (Fig. 1).30 Despite such widespread applications, it is noted that the use of Ag+ ions has become more restricted in recent years due to environmental and health concerns associated with bioaccumulation and their toxicity.31,32
On the other hand, lead is one of the most toxic heavy metal elements and has contaminated food and drinking water due to its widespread historic use in batteries, plumbing, and paints, as an anti-knocking agent in gasoline, and in the dye industry to name but a few.32,33 Considering its hazardous effects, the World Health Organization (WHO) has set a maximum permissible concentration of lead in drinking water (10 μg per litre).34 Lead is extremely toxic and it causes long-lasting health issues even with minimal contamination and it can affect reproduction, slow down development, lead to cardiovascular disorders and can result in severe health issues in children, including poor IQ, slow motor response and hypertension.35,36 It is therefore essential to take appropriate safety measures when working with silver or lead ions and their compounds, particularly in industrial settings or activities involving potential exposure. These measures include using personal protective equipment, ensuring proper ventilation, and following occupational health and safety guidelines. Additionally, it is crucial to ensure safe handling, storage, and disposal of silver and lead-containing materials to prevent environmental contamination and potential health risks to both humans and ecosystems.
The detection and quantification of silver and lead ions are essential in various fields, including environmental monitoring, industrial processes, and public health.37,38 Traditional methods, such as atomic absorption spectroscopy (AAS),39 inductively coupled plasma mass spectrometry (ICP-MS),40 ion-selective electrodes (ISE),41 X-ray fluorescence (XRF),42 and electrochemical methods,43,44 have been widely used to detect and measure the concentration of these ions in commercial setups. Most of these methods have fixed concentration ranges and sample matrices, which limit their applications in real-life sample analysis. Though it is very difficult to compare the cost-effectiveness, versatility, real-life applicability and analytical performance like selectivity, sensitivity, limit of detection, etc. of these methods for two particular heavy metal ions, a well-supported information table was presented and discussed mentioning all these specifications of some of the above-mentioned techniques somewhere else.45 Some methods are more suitable for high sensitivity and trace analysis but also need sophisticated high-end (and expensive) instrumental facilities, which can be very limiting for small and medium-sized companies. In contrast, optical sensors (either chromogenic or fluorometric) have many advantages over these conventional analytical techniques as they are mostly non-intrusive and non-destructive and exhibit high sensitivity and selectivity, which are especially beneficial for real-time monitoring, dynamic analysis, and detection of rapid changes in analyte concentrations in a complex matrix.20,46 Optical sensing techniques can be easily adapted for multiplexing, allowing the simultaneous detection of multiple analytes in a single measurement, and are therefore suitable for high-throughput analysis. Not only that, recently, optical probes have been integrated with other technologies, such as microfluidics,47,48 nanomaterials,49,50 and smart devices,51 to create advanced sensing platforms with improved performance and functionality.52
Given our ongoing interest in the development of pyrene-based fluorophores for the detection of an array of analytes of interest,53–59 we focus this review article on the use of pyrene-based fluorophores in the optical detection of the heavy metals Ag+ and Pb2+ ions. We focus on the recent developments of pyrene-based colorimetric and fluorescent sensors that have been successfully utilized in the highly selective and sensitive detection of Ag+ and Pb2+ ions independently in non-aqueous, semi-aqueous and pure aqueous media. Moreover, the crucial application of these chemosensors for in vivo detection and imaging of the respective cations is also discussed.
Fig. 2 Model structure of pyrene-based chemosensors for Ag+ and Pb2+ ions and possible binding-driven signalling modes. |
In 2002, to the best of our knowledge, for the first time, a pyrene-based chemosensor for the detection of Ag+ ions was reported.60 Kim and co-workers developed a series of calixarene-based fluoroionophores (1–3, Scheme 1) with crown and aza-crown ethers as distinct binding pockets so that the metal ions could coordinate to their preferred binding sites. It was interesting to note that a “molecular taekwondo” process was reported between the Ag+ ions, followed by either K+ or Cs+ ions via distinct fluorescence responses, which could easily be implemented in selective recognition of the metal ions. Compound 2 displayed poor emission intensity. In contrast, upon binding with the Ag+ ions, 2 displayed a sharp enhancement of emission intensity due to the inhibition of PET. Subsequently, the introduction of the K+ ions displaced the Ag+ ions just like the “coming in kicking out” fashion in a taekwondo fight and consequently the emission intensity was significantly diminished. Similar taekwondo-like behaviour was also observed with 1vs. Cu2+–K+ ions and 3vs. Ag+–Cs+ ions. From Job's plot measurements, it was observed that the probes only formed complexes of 1:1 stoichiometry with Ag+ when bound to the aza-crown sites (Fig. 3). Such consecutive fluorometric responses were rare at that time and a significant development.
Fig. 3 Pictorial representation of the probable mode of sequential binding of 2 with Ag+ and K+ ions.60 |
Ratiometric recognition of any analyte is always anticipated due to the additional advantage of internal referencing with minimum relative spectroscopic error.61,62 In the ongoing progress towards the optical detection of Ag+ ions, Yang et al. developed a pair of analogous pyrene-functionalized heterocyclic derivatives of which one (4, Scheme 1) could recognize Ag+ selectively and efficiently via monitoring the ratiometric fluorescence changes in a highly polar protic medium (EtOH–H2O; 1:1; v/v).63 Heterocycle 4 was involved in the formation of a sandwich-type complex with Ag+, thereby leading to ion-induced self-assembly of the fluorophore and a consequent significant increase in the fluorescence intensity of the excimer. Two emission bands were observed at 378 nm and 397 nm, upon excitation at 344 nm, due to typical pyrene monomeric emission behaviour. Upon binding with Ag+, a red-shifted emission band at 462 nm was observed, probably due to typical pyrene excimer emission behaviour accompanied by a sharp isoemissive point at 412 nm, facilitating ratiometric detection. Such ratiometric and dual mode detection of Ag+ ions was rare and a significant development in the field.
Shortly after Kim's report,60 a similar type of chemosensor (5, Scheme 1) was designed by Kumar et al. by assembling two pyrene moieties with a thiacalix[4]arene moiety.64 The chemosensor fluorometrically recognized both Ag+ and Fe3+ ions via two different types of fluorescence responses. Ag+ ions were detected by ratiometric fluorescence change whereas Fe3+ ions were detected by fluorescence quenching. Upon excitation at 344 nm, 5 displayed weak monomeric and strong excimer emission signals of the pyrene moiety at 377 nm and 470 nm, respectively; however, upon gradual addition of Ag+, the band at 470 nm was quenched and fluorescence enhancement at 377 nm was simultaneously observed. In contrast, the quenched emission of 5 in the presence of Fe3+ was only recovered by the addition of cysteine. Most interestingly, the reversible and reproducible fluorescence responses of 5 in the presence and/or absence of Ag+, Fe3+ and cysteine were implemented in the configuration of the Set/Reset opto-chemical logic designed feedback loop with a very useful “Write–Read–Erase–Read” feature (Fig. 4).
Fig. 4 Graphical depiction of a sequential logic circuit (a) and memory element with a useful “Write–Read–Erase–Read” feature (b) (reprinted with permission from ref. 64. Copyright 2011, American Chemical Society). |
In the same calendar year, another fluorescent probe was synthesized by anchoring two pyrene and pyridine units (6, Scheme 1) that recognized Ag+ ions ratiometrically by monitoring the monomer and excimer emission of the pyrene units.65 In HEPES buffered DMSO medium (1:1; v/v; pH = 7.2), the probe displayed a monomeric emission band at 399 nm along with an excimer band at 463 nm (λex = 344 nm). This event clearly revealed the presence of π–π interactions. Unlike the behaviour observed with other cations tested, upon the gradual addition of Ag+, the monomeric emission band of the probe was concomitantly promoted with a simultaneous decrease of the excimer emission. Extensive DFT calculations and 1H NMR spectroscopic titration clearly revealed the involvement of the nitrogen atoms in the coordination of the Ag+ ions in the 1:1 complex formation.
Thereafter, a pyrene-dipeptide-based fluorescent probe (7, Scheme 2) was developed by Jang et al. and established its role as a selective and ratiometric sensor for Ag+ as well as silver nanoparticles in water at physiological pH.66 The probe displayed emission bands at 378 nm and 395 nm due to the typical monomeric form of pyrene. The peaks concomitantly diminished with the development of a new signature emission band at 480 nm in the presence of Ag+. The probe formed an excimer in the presence of Ag+ that could easily be recognized via a typical excimer band at 480 nm with high fluorescence emission. Chemosensor 7 was shown to be capable of detecting intracellular Ag+ in live cells through strong ratiometric signals (Fig. 5). Such ratiometric detection of silver ions as well as nanoparticles in vivo and in vitro was a major advance in the field of Ag+ ion sensing.
Fig. 5 The fluorescence images of living cells (HeLa) incubated with 7 in the absence (a–c) and presence of Ag+ (d–f) under a wide range of different experimental conditions; bright field fluorescence images (a and d), λem = 435 ± 48 nm (b and e), and λem = 523 ± 35 nm (c and f); (reprinted with permission from ref. 66. Copyright 2012, American Chemical Society). |
Wang et al. synthesized a series of calix[4]arene-based chemosensors, two of which contained pyrene and non-conjugated triazole moieties on the lower-rim of the calix[4]arene (8 and 9, Fig. 6) and showed excellent ratiometric fluorescence responses towards Ag+ with excellent sensitivity even in MeOH–CHCl3 (98:2; v/v) mixed solvent.67 When excited at 342 nm, the probe exhibited strong emission peaks at 379 nm and 398 nm for monomer emission and at 476 nm for excimer emission. In the presence of Ag+, the monomeric emission bands of 8 at 379 and 398 nm were gradually enhanced with a simultaneous decrease of the excimer emission band. In contrast, 9 displayed an enhancement of emission intensity of both the monomer and excimer emission bands in the presence of silver ions. In addition, both the probes formed a 1:1 complex with Ag+ and the binding mechanism was well justified with 1H NMR spectroscopic titration. Interestingly, the probe was operative even in the presence of an aqueous methanol medium. Unfortunately, both probes also responded to Cu2+ and Hg2+ ions resulting in poorer selectivity.
Fig. 6 The binding mechanism and 1:1 complex formation of probes 8 and 9 with Ag+ ions (reprinted with permission from ref. 67. Copyright 2012, Elsevier). |
Later, Lodeiro et al. extended the synthesis protocol with a pyrene-based ligand system. The group synthesized two novel fluorescent probes bearing one and two pyrene unit-containing derivatives (10 and 11, Fig. 7) which efficiently recognized water and Ag+, as well as Cu2+ and Zn2+ ions, in dioxane medium.68 In addition to distinct spectroscopic changes, all three metal ions were distinguished with remarkable naked-eye colour changes. Interestingly, 10 displayed a higher affinity for Cu2+ whereas 11 was more responsive to Ag+. The development of such pyrene-based fluorophores with the capability to recognize and discriminate Ag+ was a significant development for real-life applications.
Fig. 7 (a) Molecular structure of the probes 10 (designated as L in the original article) and 11 (designated as P in the original article); (b) the naked-eye colour of the probes, metal ions and probe–metal ion complexes in the solution phase (reprinted with permission from ref. 68. Copyright 2013, American Chemical Society). |
In continuation of their previous study,65 a new pyrene–pyridine anchored gibbet-based fluorescent chemosensor (12, Fig. 8) was demonstrated to be selective and sensitive (LOD = 2.9 nM) for the detection of Ag+ in HEPES buffered DMSO–H2O (1:1, v/v; pH = 7.4) mixed solvent by monitoring the fluorescence “on–off” of the probe.69 In its free state, the probe displayed both monomeric and excimeric emissions. But when bound to Ag+, the formation of the excimer of the probe was restricted and PET from the metal-bound pyridine to the pyrene moiety was enhanced by the rigidity of the probe turning it into a butterfly-like skeleton, which in turn quenched the monomeric emission (Fig. 8). The probe was shown to be able to estimate the metal ion concentration in Ag+ spiked local water samples with excellent accuracy.
Fig. 8 Binding motif of 12 and the development of a rigidity enhanced butterfly-like skeleton with Ag+ (reprinted with permission from ref. 69. Copyright 2014, The Royal Society of Chemistry). |
Chang et al. synthesized a probe (13, Fig. 9) having several binding possibilities with different analytes and used it to detect silver ions, formaldehyde and fructose.70 The probe utilised a number of binding interactions such as a dynamic covalent interaction between a diol and boronic acid, silver ion and pyridyl ligand, through a coordination interaction and an easily accessible reaction possibility between the secondary amine and formaldehyde with pyrene as the fluorophore. Compound 13 reacted with fructose and formed a blue coloured fluorescent adduct that further reacted with Ag+ to form a 2:1 complex with the pyridyl residues with a change in solution colour from blue to green. The complete and multiple binding motifs of the probe in different dynamic states with different analytes along with the fluorescent colour changes are presented in Fig. 9.
Fig. 9 Pictorial representation of the relevant states of the dynamic molecular system 13 in the presence of different analytes.70 |
A new technique has been developed by Zhang et al. to selectively detect silver ions using supramolecular assembly of a water-soluble pyrene derivative (14, Scheme 3) and cucurbit[10]uril.71 The 1:1 host–guest type inclusion complex recognized Fe3+ and Ag+ ions independently. In the presence of Ag+, the composite displayed an enhancement of emission intensity at 332 nm due to an alteration of the ICT character and the fluorescence change was observed in confocal microscopy images (Fig. 10). Remarkably, the sensor system was extremely selective towards these metal ions over 37 other metal ions. Application of such a host–guest type inclusion complex as an Ag+ ion sensor was new, rare and innovative.
Fig. 10 (a) Fluorescence spectral changes of 14 with gradual addition of Ag+; confocal images of 14 in the absence (b) and presence of Ag+ (c) (reprinted with permission from ref. 71. Copyright 2020, Elsevier). |
In 2020, Lavado et al. synthesized and characterized a pair of calix[4]arene based sensors (15 and 16, Scheme 4) with thiourea as a spacer and pyrene or methylene–pyrene as the fluorophore, which selectively recognized silver ions with nanomolar scale sensitivity.72 In a UV-vis spectroscopic study, 15 showed a defined band at 280 nm and two other overlapping bands at 332 and 347 nm in an acetonitrile–DMSO (99:1) solvent mixture. In the emission spectra, 15 displayed a band at 406 nm whilst 16 showed three bands at 377, 395, and 472 nm. Upon inclusion of Ag+, 15 showed a sharp quenching of fluorescence intensity at 406 nm, whereas 16 exhibited a totally different decrease of the pyrene excimer band at 472 nm. The sensitivity was remarkable, but both the probes suffered from selectivity issues with Hg2+ ions, which also quenched fluorescence. Interestingly, using chemical inputs and respective emission spectral results, several useful opto-chemical logic gates like INHIBITION and IMPLICATION were designed.
Very recently, Ju et al. synthesized a pair of argentivorous fluorophores (17 and 18, Scheme 4) containing anthracenyl– or pyrenyl–benzyl moieties.73 Probe 17 showed a bright emission at 506 nm (ϕ = 0.46) but its emission was significantly reduced (ϕ = 0.16) in the presence of silver ions (Fig. 11). This quenching event was initiated due to the PET from the amine to the nearby anthracene moiety. On the other hand, probe 18 displayed a weak blue emission at 409 nm (ϕ = 0.14) but that was changed suddenly in the presence of Ag+ with bright blue luminescence at 462 nm (ϕ = 0.40) being observed. The poor fluorescence emission of 18 was attributed to PET from the nitrogen atom of the cyclen moiety to the excited pyrene moiety. The inclusion of the Ag+ ion was proposed to inhibit the PET and enhanced rigidity due to the CHEF effect also boosted the fluorescence intensity sharply. Interestingly, the report established the structure–fluorescence change relationship for the cyclen-based receptor.
Fig. 11 Pictorial representation of the binding motifs of the probes 17 and 18 with the Ag+ ion (reprinted with permission from ref. 73. Copyright 2021, American Chemical Society). |
The above examples demonstrate the colorimetric and fluorescence detection of Ag+ ions by pyrene-based fluorophores, which in most cases utilise architectures in which the pyrene was tethered with either pyridine or calix[4]arene moieties. In a few cases, amines or substituted amines were integrated with pyrene moieties. The nitrogen centres of all these pyrene-based fluorophores were involved in selective coordination with Ag+ and altered either the monomer–excimer emission behaviour, PET phenomenon or chelation-enhanced fluorescence behaviour. Fluorophore–cucurbit[10]uril host–guest inclusive complexation was also employed as a chemosensing mechanism. Few of the chemosensors, however, were able to recognize Ag+ by naked-eye colour change. Nonetheless, the ion-induced spectroscopic responses observed were utilized in the development of opto-chemical logic gates and memory devices in several cases. Unfortunately, it was observed that most of the Ag+ ion chemosensors failed to distinguish the Hg2+ ion.
Finally, a sensor information table for the Ag+ sensors discussed above containing basic information like the binding unit, medium, nature of fluorescence response, photo-process involved, LOD, and any special features is presented, Table 1.
Binding unit | Medium | Fluorescence response | Photoprocess | LOD | Special feature | Ref. |
---|---|---|---|---|---|---|
Calixarene-based crown ether & aza-crown ether (1–3) | EtOH | Turn on | Inhibition of PET and CHEF | — | “Molecular taekwondo” between metal ions | 60 |
Heterocyclic macrocycle (4) | EtOH–H2O; 1:1; v/v | Ratiometric | Formation of an excimer | — | Ion-induced self-assembly driven formation of an intramolecular sandwich complex | 63 |
Thiacalix[4]arene (5) | 10% aqueous ethanol | Ratiometric | Conformational change | — | Configuration of Set/Reset opto-chemical logic designing in a feedback loop with a very useful “Write–Read–Erase–Read” feature | 64 |
Bispyrene–pyridine derivative (6) | HEPES buffered DMSO | Ratiometric | Inhibition of ICT | — | Monomer–excimer switching | 65 |
Histidine-tryptophan dipeptide (7) | Aqueous solution containing 1% DMF | Ratiometric | Formation of an excimer | — | In vivo detection of Ag+ within HeLa cells | 66 |
Calix[4]arene-triazole derivative (8 and 9) | MeOH–CHCl3 (98:2; v/v) | Ratiometric | CHEF | — | Interconversion between dynamic and static excimers | 67 |
Aminophenoxy-oxopentane (10 and 11) | Dioxane | Quenching | Monomer to dimer conversion | — | Prominent naked-eye color change | 68 |
Pyridine derivative (12) | HEPES-buffered DMSO–H2O | “Turn off” | PET | 2.9 nM | Butterfly like architecture | 69 |
Pyridine-boronic acid-fructose adduct (13) | Carbonate buffered DMSO | Ratiometric | Formation of an excimer | 2.5 μM | Aggregation–disaggregation | 70 |
Aminopropyl-pyrene derivative-cucurbit[10]uril inclusion complex (14) | H2O | Enhancement of fluorescence intensity | ICT | — | Inclusion complex as a chemosensor | 71 |
Calix[4]arene-thiourea derivative (15 and 16) | MeCN–DMSO (99:1; v/v) | Quenching of excimer emission | Through bond and cation–π interaction | 2.09 nM | Decoration of INHIBITION and IMPLICATION opto-chemical logic gates | 72 |
Tetra-armed cyclens (17 and 18) | — | “Turn on” | PET & CHEF | — | Detection of ions in the solid state | 73 |
In 2004, Kim et al. developed a pair of new fluorescent sensors (19 and 20, Scheme 5) with two pyrene moieties linked to a cation recognition unit of a 1,3-alternate calix[4]arene framework that selectively recognized Pb2+ and K+ ions. The probe formed an excimer in solution that displayed an emission band at 470 nm, which was quenched by Pb2+ but subsequently revived by the addition of K+.74 Two pyrene moieties with a cation recognition unit made of an amide linkage created a potent monomer and excimer in the free ligand. When metal ions were added, the emission spectral behaviour was entirely changed. Whilst 19 was highly selective towards both Pb2+ and K+ individually and sequentially in a reversible manner, 20, which had propyl groups in place of the crown-5 ring, had high selectivity only for Pb2+. Both the monomer and the excimer bands were significantly quenched upon the addition of Pb2+ to a solution of 19 in MeCN solution because of reverse PET from the pyrene group to the amide group. It was important to note that when K+ was introduced to a solution of 19, the emission behaviour remained unaltered because K+ was trapped by the crown-5 ring rather than the amide group.
The same group also developed another pair of new fluorogenic calix[4]arene-based chemosensors (21 and 22, Scheme 5) containing triazacrown-5 with two pyrenyl amide groups that can be used for both cation and anion-selective chemo-sensing purposes.75 While compound 21 emitted at 448 nm, compound 22 emitted at 472 nm. The difference of 24 nm blue shifted emission between the two compounds was due to the triazacrown ring's steric hindrance across the two pyrene pendants. When Pb2+ or Co2+ was introduced to 22, the fluorescence intensities were quenched due to the effects of the metals, reverse PET, and conformational changes. The two pyrenyl amide groups contributed significantly to the selective Pb2+ ion complexation by using an azacrown unit. Interestingly, the 21–Pb2+ composite also recognized fluoride ions driven by anion selective hydrogen bonding interactions.
In a different study by the same group, three pyrene derivatives were developed by assembling calix[4]arenes connected with a pendant like ethyleneamine on their triazacrown ring (23–25, Scheme 6).76 Compounds 23 and 24 displayed weak monomer and excimer emission bands at 396 nm and 467 nm, respectively (λex = 343 nm), due to PET from the hanging pendant-like –CH2CH2NH2 moieties appended to the fluorogenic pyrenes. In contrast 25, which did not contain these pendant-like moieties, displayed strong monomer and excimer emission. When Pb2+ was added to a MeCN solution of 23 and 24, the monomer emission increased gradually, while the excimer emission was diminished simultaneously. However, for 25 both the monomer and excimer emissions were decreased significantly upon binding with Pb2+. This was because of the carbonyl bond change in orientation and the primary amine being involved in the three-dimensional encapsulation. The quenching of excimer emission of 23 and 24 was attributed to inhibition of PET due to involvement of the –CH2CH2NH2 moiety coordinating with Pb2+, disfavouring excimer formation. But for 25, the CO⋯Pb2+ coordination and subsequent conformational changes initiated the quenching of excimer emission, whereas the heavy metal ion effect and reverse-PET collectively originated the monomer quenching. Moreover, 23 and 24 displayed high selectivity and sensitivity towards fluoride ions.
In 2006, Choi et al. devised a pair of pyrene-based fluoroionophores (26 and 27, Scheme 7), one of which contained two cation recognition sites (a crown ether ring and two facing pyreneamide groups) and displayed different chemosensory responses with two transition metal ions, Pb2+ and Cu2+, and one alkali metal ion, K+. In these multiple metal ion detection events, photoinduced charge transfer (PCT) was reported to take a crucial role in producing distinguishable spectroscopic patterns.77 Both the compounds displayed monomer (λem = 384 nm) as well as excimer (λem = 484 nm) emissions upon illumination at 343 nm in acetonitrile solution. The monomer and excimer emissions of 26 were quenched in the presence of both Cu2+ and Pb2+ due to reverse PET and conformational changes. The Pb2+ ion was proposed to be bound to two adjacent amide oxygen atoms of 26 and not with the crown ether ring, as control compound 27, which did not contain the crown ether ring, also displayed similar quenching of both monomer and excimer emission bands upon inclusion of Pb2+. However, the observed spectral changes upon the addition of K+ ions were different. Upon binding with K+, 26 displayed enhancements of the excimer emission band, probably due to binding at the crown ether ring. Interestingly, 26 displayed exchanges of cations with consecutive addition of Pb2+ followed by K+ ions due to electrostatic repulsion between two metal ions. This work was not only important from a fluorescence detection point of view but also for the ion-exchange phenomenon (Fig. 12).
Fig. 12 Pictorial representation of the binding motifs of the probe 26 with Cu2+, Pb2+ and K+ ions (reprinted with permission from ref. 77. Copyright 2006, American Chemical Society). |
In the same year, the group also reported another pair of tetrahomodioxacalix[4]arene-pyreneamide tethered pyrene derivatives (28 and 29, Scheme 7), which selectively and efficiently recognized Pb2+ and Ca2+ ions in CHCl3–MeCN (1:3; v/v) mixed solvent.78 While Ca2+ ion binding caused the receptor to produce an elevated excimer and a decreased monomer emission with a ratiometric response, Pb2+ coordination resulted in quenched monomer and excimer fluorescence emission. Frontier molecular orbital analysis of 29 established the variations in excimer emission spectra by explaining why the effective π–π* interaction caused an increase in emission intensity upon Ca2+ ion complexation, but not upon Pb2+ binding. Coordination between 29 and Pb2+ disfavoured the formation of H-bonding in the pyrenyl amide moieties and consequently discarded the possibility of Py–Py* interactions and resulted in quenched excimer emissions.
Later, Kumar et al. synthesized a trio of analogous calix[4]arene-pyrene assembled fluorophores (30–32, Scheme 8) and established their selective binding ability towards Pb2+ over other various metal ions in CH2Cl2:MeCN (1:1; v/v) mixed solvent.79 Interestingly, the probes 30 and 31 showed ratiometric spectroscopic changes but 32 only displayed “on–off” behaviour upon binding with Pb2+. In an absorption study, 31 showed typical absorption bands at 363, 372, and 393 nm. Upon addition of Pb2+ to the solution of 31, the absorption band due to the aza-bridge at 363 nm gradually decreased with simultaneous formation of a new red-shifted absorption band at 451 nm through the intermolecular charge transfer phenomenon (ICT). Also, with the incorporation of Pb2+, 31 displayed a ratiometric shift of emission spectra, through an increase of the excimer band at 502 nm and a decrease of the monomer band at 407 nm. The reverse PET process to the imine nitrogen from the photoexcited pyrene was proposed to be responsible for the monomer quenching, and simultaneous conformational rigidity due to metal complexation resulted in the augmentation of the excimer band. On the other hand, 32 displayed strong quenching of its excimer band at 486 nm due to a reverse PET process. In addition, the 1:1 binding stoichiometry and sub-nanoscale detection limit (LOD = 490, 100 and 290 nM for 30, 31 and 32, respectively) were also determined. Such diverse behaviour of analogous fluorophores towards a particular metal ion was very interesting.
On the backbone of homooxacalix[3]arene, a pair of entirely novel types of fluorescent chemosensors (33 and 34, Scheme 9) that recognized Pb2+ ions in MeCN:H2O:DMSO (1000:50:1; v/v/v) mixed solvent were reported by Ni et al. The group established far better chemosensory behaviour of 34 over 33 towards Pb2+.80 Gradual addition of Pb2+ resulted in a ratiometric shift of emission bands of 34. When excited at 343 nm, the monomeric emission band of 34 at 396 nm was promoted with a simultaneous decrease of the excimer emission band upon complexation with Pb2+ ions. Such a ratiometric fluorescent chemosensor for the heavy metal ion with the homooxacalix[3]-arene C3 symmetric structure displaying ratiometric enhancement of monomeric emission was very unusual at this time.
Later, Wang et al. developed a pyrene–pyridine-based fluorescent Schiff base connected by acetylenic linkers (35, Scheme 9) that selectively recognized Pb2+ and Ni2+ ions independently in DMF–H2O mixed solvent.81 Remarkably, the chemodosimeter was visible light excitable and exhibited fluorescence “on–off” responses in the presence of Ni2+ and “green–red” fluorescence switching upon binding with Pb2+ with different response times. Upon excitation at 460 nm, 35 displayed strong emission bands at 509 nm and 545 nm (φ = 0.438). The addition of Pb2+ to the solution of 35 not only reduced the emission intensity (φ = 0.085) but also increased the intensity ratio (I545/I509) from 0.334 to 1.114. Notably, the reaction time for Pb2+ was delayed in comparison with the Ni2+ ion, which might be a tool to distinguish the cations. Such a fluorescent probe could therefore demonstrate two new, highly effective ways for differentiating between Ni2+ and Pb2+ ions through different binding behaviours of the “in situ” produced Ni2+ and Pb2+ complexes with ethylene diamine (EDA) (Fig. 13).
Fig. 13 Pictorial representation of different binding motifs of 35 with Ni2+ and Pb2+ ions with corresponding fluorescent colour changes and quantum yield values (reproduced with permission from ref. 81. Copyright 2012, The Royal Society of Chemistry). |
Thereafter, Oton et al. developed three ferrocene-triazole tethered derivatives with a variable aromatic moiety by tandem click/Staudinger–aza Wittig reactions.82 Among the three derivatives produced, the Pb2+ sensing properties of pyrene derivative 36 were explored by electrochemical and spectroscopic methods in MeCN:CH2Cl2 (4:1; v/v) mixed solvent. Upon interaction with Pb2+, the absorption band of the probe displayed a ratiometric blue shift from 382 to 347 nm accompanied by a yellow to yellowish red colour and a sharp increase of emission intensity (φ = 0.027) from a very poor fluorescence emission (φ < 0.001). Such enhancement of emission intensity was attributed to a CHEF process (CHEF = 125). Hitherto, heavy metal ions like Pb2+ have mostly exhibited quenching of emission intensity as their detection method, and such “turn on” based detection was very rare.
In 2013, Neupane et al. synthesized a pyrene-tryptophan tethered fluorophore (37, Scheme 10) that fluorimetrically recognized Pb2+via a “turn on” response of the monomeric band at 380 nm and Hg2+via “turn on” responses of both the monomeric (380 nm) and excimeric bands (475 nm) in HEPES buffered aqueous solutions (pH = 7.4).83 The probe 37 itself showed typical weak emission bands at 378 nm and 395 nm. The poor emission was due to PET from the tryptophan to the pyrene moiety. The binding of Pb2+ with the indole group impeded the PET process with the consequential enhancement of monomeric emission of the pyrene moiety. The exclusive role of the tryptophan moiety as a ligand and a quencher for recognition and fluorescence changes upon metal binding has not been explored previously.
Thereafter, Thakur et al. synthesized two pairs of electrochemical and optical sensors (38–41, Fig. 14) by assembling ferrocene–triazole–anthracene and ferrocene–triazole–pyrene (one pair each) via click reactions.84 In addition to electrochemical responses, the probes exhibited significant promotion of the characteristic emission band upon binding with Pb2+ in MeCN–H2O (2:8; v/v) mixed medium. The fluorescence “turn on” responses enabled high fidelity nanomolar scale detection of Pb2+, even over other typically competing cations like Hg2+ and Cd2+ ions. Such a “turn on” response was attributed to the consequence of CHEF. Another advantageous aspect of this study was the pronounced naked-eye colour changes (Fig. 14) of the chemosensors in the presence of Pb2+ (from yellow to greenish blue). Such a readily observed chromogenic colour change could prove very convenient for real-life and on-site application of the chemosensors.
Fig. 14 Probable binding mode of (a) 38, (b) 39, (c) 40 and (d) 41 with Pb2+; chromogenic colour change of (e) 38 and (f) 39 with different metal ions including Pb2+ (reproduced with permission from ref. 79. Copyright 2013, American Chemical Society). |
The same group then developed another two pairs of chromogenic and fluorescent probes using click reactions, two of which displayed excellent selectivity and sensitivity (LOD = 2 ppb) towards Pb2+.85 Among the two Pb2+ chemosensors, the pyrene–triazole–carbohydrate anchored fluorophore (42, Scheme 11) was able to detect Pb2+ with the naked eye with a prominent colour change from colourless to greenish blue. The probe itself was highly fluorescent in nature, but suffered from significant quenching in the presence of Pb2+ in an aqueous medium (MeCN–H2O; 2:8; v/v). In comparison with their previous study,84 with replacement of the ferrocene moiety by a carbohydrate, the nature of the fluorescence response was reversed in the same semi-aqueous medium. Here, the quenching was driven by spin–orbit coupling in combination with energy transfer mechanisms. In addition, 1:1 binding stoichiometry and chemosensory responses of 42 towards Hg2+ were also documented.
Intrigued by “constitutional dynamic chemistry”, Chang et al. adopted a new strategy to develop molecular beacon-like fluorescent probes (43 and 44, Scheme 11).86 The molecular beacon-like fluorescent probes were actually two ion-pairs composed of either EDTA or sulfuric acid (the anionic counterion of the cation) and two units of residues combining an amino-containing pyrenyl derivative on a hydrophobic cholesterol backbone (cationic counterpart). EDTA and sulfuric acid were used separately as physical linkers to combine two units of the pyrene–cholesterol residues together via proton transfer to develop the ion-pair. Cholesterol is popular for its unique solvent polarity dependent self-assembly phenomenon and hence is regularly used as a building block of gelators of low molecular mass. The same property was observed here. Probe 43 displayed aggregation behaviour in n-hexane but swelling was observed in chloroform or MeOH. It was successfully utilized for the distinct recognition of two cations, Ba2+ and Pb2+, over others tested by the development of excimer emission bands and colour changes under UV-light (Fig. 15). The probes were also successfully used to evaluate the purity of n-hexane, and likely the development of such biocompatible, molecular beacon-like fluorescent sensors using this strategy is a gateway to future research in the field.
Fig. 15 Plausible binding mechanism of (a) 44 with Ba2+/Pb2+ ions along with (b) colour change of 44 in the presence of different metal ions (reproduced with permission from ref. 86. Copyright 2015, American Chemical Society). |
Inspired by utilising the principles of the coordination chemistry of metal ion binding and aggregation, Zhao et al. developed a fluorophore containing a hydrophobic group and a pair of pyrene units (fluorophore) connected by a flexible hydrophilic group (45, Scheme 12) and employed it for the selective and high-fidelity fluorescence detection of Fe3+ and Pb2+ ions in a semi-aqueous medium.87 Such a molecular beacon-like shape of the probe was suitable for the formation of an excimer. As expected, in H2O–MeCN (3:2; v/v) mixed solvent, the probe showed its characteristic excimer emission band at 481 nm and a poor monomeric band in the range of 370–400 nm. However, the probe displayed similar fluorescence quenching in the presence of Fe3+ and Pb2+ ions though the extent of quenching in the presence of Fe3+ was stronger than in the presence of Pb2+ (binding constant = 1.78 × 1011 and 9.60 × 107 L2 mol−2 for Fe3+ and Pb2+, respectively). In addition, unlike Fe3+, Pb2+ did not result in the formation of flocculent precipitates in solution. Interestingly, the fluorescence responses were almost the same over a relatively wide pH range of 4.0 to 7.5. Upon switching of the solvent to H2O–DMSO (3:2; v/v), both Fe3+ and Pb2+ exhibited quenching to an almost comparable extent, with both resulting in flocculent precipitates which were white for Pb2+ and yellow for Fe3+. The presence of a carbonyl group played a significant role in the coordination of the metal ions and the consequent development of a highly hydrophobic 1:1 metal complex. Remarkably, this work not only outlined the fluorescence recognition of Fe3+ and Pb2+ ions but also distinguished the two cations as well as demonstrated the removal of the metal ions from aqueous solution.
Later, Zhang et al. reported a new approach for the detection of multiple cations, including Pb2+, in aqueous medium.88 A composite sensor system was developed by the integration of a fluorophore, a picolyl-modified pyrene derivative (46, Scheme 12) and an anionic surfactant, sodium dodecyl sulfate (SDS). 46 displayed typical pyrene absorption peaks in the UV-visible range at 268, 279, 351, and 379 nm, and the emission spectra showed monomeric emission bands at 379 and 399 nm. Interestingly, the fluorophore–surfactant ensemble displayed multiple emission bands in the presence of 13 common metal ions and the fluorescent pattern was utilized in the principal component analysis (PCA) of the metal ions (Fig. 16). In addition to Pb2+, the binary sensor system recognized Mg2+, Al3+, Ca2+, Cr3+, Fe3+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Hg2+ and Ba2+ ions. Remarkably, this method could be employed in the discrimination of disinfected drinking water and mineral water of different brands, and the development of a binary composite sensor for the recognition and discrimination of multiple metal ions employing a PCA strategy was a remarkable innovation.
Fig. 16 Schematic diagram of the detection strategy of different metal ions by the ensemble sensor using the PCA method (reproduced with permission from ref. 88. Copyright 2017, American Chemical Society). |
Recently, Merz et al. developed a pyrene-based “turn-off” fluorescent probe (47, Fig. 17) and employed it to detect and quantify environmentally important metal ions such as Cu2+, Pb2+ and Hg2+, with long fluorescence lifetimes and a rigid sensor architecture.89 The formation of a 1:1 probe–cation complex during the course of the reaction was confirmed by Job's plot and bindfit software. In addition, at higher quencher concentrations, the Stern–Volmer plots showed a complex web of interactions that included the reversible, metal-induced production of nanosized aggregates in addition to the stoichiometric complex (Fig. 17). If the system could be immobilized on a solid base to stop aggregation, some interesting real-life application might be found.
Here, we have observed that for the detection of Pb2+, several types of binding units like calix[4]arene, triazole, indole, cholesterol, push–pull dye, pyridine, ferrocene and Schiff bases have been integrated with pyrenes. Also, different materials like ion-pair, molecular beacon, and fluorophore–surfactant ensemble and the PCA technique have been employed. But unlike Ag+ sensing, there is a huge diversity in the binding mechanism and fluorescence responses. The inclusion of Pb2+ into these systems has displayed a ratiometric shift of the monomer and excimer bands, quenching of either the monomer or excimer band and promotion of the excimer band. Despite all of these achievements, there is still some scope for future developments. Among all of these pyrene-based Pb2+ chemosensors, there are few (Table 2) that have high fidelity detection capacity in pure water. This is essential for real-life applications and is an area that needs to be developed. As for Ag+, for ease of comparison between different sensor systems, basic information like the binding unit, medium, nature of the fluorescence response, photoprocess involved, and LOD and highlights of any special features are presented.
Binding unit (probe number) | Medium | Fluorescence response | Photoprocess | LOD | Special feature | Ref. |
---|---|---|---|---|---|---|
Calix[4]arene (19 and 20) | MeCN | Quenching | PET & conformational change | — | Dual ion sensing | 74 |
Calix[4]triazacrown (21 and 22) | MeCN | Quenching | PET | — | Dual ion sensing | 75 |
Calix[4]arene-ethyleneamine-triazacrown (23–25) | MeCN | Quenching | PET & CHEF | — | Dual ion sensing | 76 |
Calix[4]crown (26 and 27) | MeCN | Quenching | PCT & PET | — | Consecutive dual ion sensing | 77 |
Tetrahomodioxacalix[4]arene pyreneamides (28 and 29) | CHCl3–MeCN (1:3; v/v) | Quenching | PET | — | Dual ion sensing | 78 |
Calix[4]arenes (30–32) | CH2Cl2–MeCN (1:1; v/v). | Quenching | PET | 290 nM | Prominent naked-eye color change | 79 |
Homooxacalix[3]arene-triazole derivative (33 and 34) | MeCN–H2O–DMSO (1000:50:1; v/v) | Ratiometric | Heavy metal quenching | — | Remarkable selectivity | 80 |
Pyridine derivative (35) | DMF–H2O (1:1; v/v) | Quenching | Metal coordination | — | Visible light excitable fluorescent chemodosimeter | 81 |
Ferrocene-triazole derivative (36) | MeCN–CH2Cl2 (4 : 1; v/v) | “Turn on” | CHEF | 590 nM | Electrochemical and optical detection | 82 |
Tryptophan derivative (37) | HEPES buffered MeCN | “Turn on” | PET | — | First report of an amino acid residue as a Pb2+ chemosensor | 83 |
Triazole-tethered ferrocene (38–41) | MeCN–H2O (2:8; v/v) | “Turn on” | CHEF | 2 ppb | Sharp naked-eye color change | 84 |
Triazole-carbohydrate derivative (42) | MeCN–H2O (2:8; v/v) | Quenching | Spin–orbit coupling & energy transfer | 2.0 nM | Sharp naked-eye color change | 85 |
Cholesterol amino acid anchored molecular beacon (43 and 44) | CHCl3–n-hexane | Quenching | Monomer–excimer conversion | — | Ion-pair as a chemosensor | 86 |
Butyroyl-ornithine derivative (45) | H2O–DMSO (3:2; v/v) | Quenching | Aggregation | — | Solvent-dependent ion sensing behavior | 87 |
Bis(2-picolyl)amine-modified pyrene-SDS composite (46) | H2O | — | Aggregation | — | Application of the PCA method | 88 |
Tetraethylene glycol-triazole derivative (47) | MeCN | Quenching | Aggregation | 600 nM | Multiple metal ion sensing | 89 |
A range of different moieties have been assembled with pyrene to improve the selectivity and sensitivity of analyte detection. Most of the chemosensors reported herein displayed very sharp and distinguishable colour changes upon binding with these two metal ions and the spectroscopic responses were utilized, in the design of different high-utility and popular opto-chemical logic gates and memory units. Interestingly, in the presence of Ag+, most of the pyrene-based chemosensors displayed ratiometric fluorescence changes but their application in mixed analyte samples is frequently hampered by competing responses from other analytes. In case of Pb2+ ion, just reversed fluorescence responses, with quenching of either the monomer or excimer emission band, were observed, rather than the more desirable ratiometric fluorescence changes being observed. Therefore, a contemporary challenge remains to establish new systems that can exploit the ratiometric potential of pyrene systems in the detection of Pb2+ ions. Despite the considerable number of pyrene-based chemosensors for silver and lead ions that have now been reported, none of them have yet been able to detect either of the metal ions with high fidelity in pure aqueous medium. This is an essential pre-requisite for their real-life detection and remains an enduring challenge for the future if such systems are to replace the traditional high-end analytical methods currently employed.
CHEF | Chelation enhanced fluorescence |
DFT | Density functional theory |
EDTA | Ethelene diamine tetraacetic acid |
HB | Hydrogen bonding |
ICT | Intramolecular charge transfer |
LOD | Limit of detection |
MB | Molecular beacon |
PA | Picric acid |
PCA | Principal component analysis |
PCT | Photoinduced charge transfer |
PET | Photoinduced electron transfer |
SDS | Sodium dodecyl sulfate |
This journal is © The Royal Society of Chemistry 2024 |