Devashish
Gokhale‡
a,
Patritsia M.
Stathatou‡
*bc,
Christos E.
Athanasiou
d and
Patrick S.
Doyle
*ae
aDepartment of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. E-mail: pdoyle@mit.edu
bRenewable Bioproducts Institute, Georgia Institute of Technology, Atlanta, GA 30332, USA. E-mail: patricia@gatech.edu
cCenter for Bits and Atoms, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
dDaniel Guggenheim School of Aerospace Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
eHarvard Medical School Initiative for RNA Medicine, Boston, MA 02215, USA
First published on 15th May 2024
Trace heavy metals are present in water resources globally, jeopardizing ecosystems and human health. Lead is one of the most prevalent and toxic trace pollutants, with numerous incidents of lead-contaminated drinking water across the United States. Conventional treatment processes fail to remove trace lead from water in a resource-efficient manner. Yeast can effectively remove lead from water via a rapid mass transport process, called biosorption, even when lead concentrations are below 1 part-per-million. Rapid and high lead uptake can enable the application of this inexpensive and abundant biomaterial to water treatment, but scalability is limited by the need to remove any added yeast from water. Here, we scale up a yeast-based treatment process without requiring additional separation steps. Yeast cells are confined within hydrogel capsules that are sufficiently large for easy separation from water by gravitational settling, and sufficiently porous not to limit adsorption capacity and kinetics. The yeast-laden capsules exhibit an uptake capacity of 21 mg g−1, comparable to free yeast under the same conditions, reaching equilibrium within the first 5 minutes of contact. We assess the mechanical robustness of the yeast-laden capsules, and construct a lab-scale proof-of-concept packed-bed biofilter, capable of treating trace lead-contaminated water and meeting USEPA drinking water guidelines while operating continuously for 12 days, to demonstrate the scalability of our approach. By overcoming common separation and structural stability issues that limit scalability of biological water treatment methods, our work offers an innovative and sustainable solution targeting emerging contaminants.
Sustainability spotlightLead is highly toxic even at trace concentrations, posing a significant health threat despite regulations. Conventional treatment processes are expensive, unsustainable, and resource inefficient. Low-cost yeast-based solutions are promising alternatives but are hindered by the need for additional separation to remove yeast from water. We address this limitation by encapsulating yeast cells in hydrogel capsules made in facile, scalable processes, and use the capsules to create affordable, long-lasting, flow-through filters that treat contaminated water to drinking water standards. Careful hydrogel design ensures effective yeast retention without compromising lead adsorption capacity, mechanical robustness, and removal kinetics. This strategy, applicable to diverse water treatment methods, offers an environmentally friendly, transformative approach to water quality enhancement with broad implications for global health. |
The US Environmental Protection Agency (USEPA) established the Lead and Copper Rule in 1991 to control lead in drinking water and protect public health.11 According to this rule the Maximum Contaminant Level Goal (MCLG) for lead is zero, since there is no safe level of lead exposure (as even trace amounts ingested over time can result in adverse effects due to bioaccumulation). This rule also established action levels for lead in drinking water as measures of the effectiveness of the corrosion control treatment in water systems. The action level for lead is 15 parts per billion (ppb), and if lead concentrations exceed this action level in more than 10% of the customer taps sampled, then several control actions must be performed including public education and lead service line replacement.12 The rule was revised in 2021 introducing a lead trigger level of 10 ppb for proactive planning in communities with lead service lines.13 Although the MCLG for lead in the US is zero, a study in 2021 uncovered detectable, alarming lead levels in almost all water samples collected from 120 sites across 36 US states ranging from 0.01–11.20 ppb.14,15
Several physicochemical water treatment methods exist for removing trace lead from drinking water at the household and community levels, with reverse osmosis (RO) filtration systems being among the most efficient ones. Nonetheless, such systems result in substantial financial and environmental costs to eliminate trace lead amounts.16 Costs of RO systems range from around $150 for under-the-sink compact filters to $20,000 for commercial or large residential setups, without including the significant installation and maintenance expenses.17 In parallel, RO systems generate considerable volumes of wastewater to operate, since typical point-of-use systems can generate 5–10 gallons of wastewater for every gallon of treated water produced with the more efficient units achieving a 1:1 rejected to clean water ratio.17,18 They also require significant amounts of energy (∼4 kW h m−3 of water19), roughly an order of magnitude higher than the average specific energy expenditure of US water and wastewater treatment facilities.20
Biosorption, a mass transfer process by which an ion or molecule binds onto inactive biological materials by physicochemical interactions,21 can offer a sustainable and effective alternative to conventional processes. As shown previously,1 trace lead can be effectively removed from water by using the yeast Saccharomyces cerevisiae (S. cerevisiae). Yeast rapidly treats water with environmentally relevant initial lead concentrations below 1 part per million (ppm), attaining equilibrium within the first 5 min of contact. Most adsorption processes in water treatment facilities have limited contact times (∼10 min), making rapid removal essential.22,23 Further, S. cerevisiae yeast can be acquired at minimal or even zero cost in large quantities, as a common waste product of various fermentation industries.24–26 Surplus yeast is currently produced in huge volumes and is an extremely underutilized low-value resource not suitable as a human dietary supplement due to high levels of nucleic acids.1,27 The large-scale application of this inexpensive and abundant biomaterial could be highly advantageous to achieve rapid and high lead uptake, while enhancing the application of circular economy models within local contexts. The main limitation in implementing such processes resides in the need for supplementary treatment stages to remove the introduced yeast from water.
In this study, this limitation is overcome through the encapsulation of yeast cells in hollow capsules made of poly(ethylene glycol) diacrylate (PEGDA) hydrogel (Fig. 1). PEGDA capsules are more stable than other hydrogels used in literature due to chemical crosslinking.28 PEGDA is an economical and biocompatible material that has seen prior use in water treatment applications.29 The developed hydrogel capsules serve as yeast-containing vessels, large enough to be easily separated from water under the effect of gravity or by using commercial frits that do not significantly contribute to pressure drop. Hydrogels have several inherent advantages that make them an ideal platform to encapsulate yeast cells, increasing the effective size of the cells while retaining functionality. For instance, hydrogels have seen extensive use in water treatment in prior work, and are known to rapidly sequester contaminants due to their high porosity which allows rapid mass transport.29–31 Hence, encapsulating yeast inside hydrogels is expected not to impose significant kinetic limitations on the treatment process compared to using free yeast cells in water. Furthermore, a significant body of work in the field of bioengineering demonstrates that hydrogels can be made using chemistries compatible with yeast cells,32,33 implying minimal function-affecting interactions between the cells and the surrounding hydrogel matrix. Therefore, it can be expected that encapsulating yeast cells within hydrogel particles will not significantly affect yeast–lead interactions.
We demonstrate the use of hydrogel beads and capsules synthesized using an off-the-shelf microfluidic device (micro-cross) to indefinitely encapsulate yeast and rapidly clean lead-contaminated water at environmentally relevant concentrations (ppb levels). Our results showcase that the use of hollow PEGDA hydrogel capsules offers significant advantages as a support matrix over solid hydrogel beads. A capsule-based formulation protects yeast cells from the polymerization reaction and enables their direct contact with contaminants, avoiding potential kinetics and adsorption limitations occurring from yeast–hydrogel interactions. In addition, the capsules have sufficient mechanical robustness to enable their use in a packed-bed, flow-through biofilter that serves as a proof-of-concept bioreactor illustrating the scale-up potential of the proposed approach. Previous attempts to scale-up biosorption using immobilized microbial cells have failed mostly due to chemical alterations of cell structures caused by immobilization agents, lack of mechanical robustness, and unfavorable solute mass transfer rates.21 In contrast, our approach successfully addresses these challenges, enabling yeast to perform nearly as effectively as in its free state while encapsulated. Overall, this work overcomes separation and structural stability issues that could limit biosorption scalability and showcases the scale up of a highly effective, environmentally friendly, inexpensive, benign to human health, and easy-to-mass-produce advanced treatment process that could be applied to target emerging contaminants, enabling circular economy models.
The microfluidics setup is assembled as shown in Fig. S1†. All parts (excluding syringes) are ultrasonicated in a 1 M sodium hydroxide (NaOH) (VWR, USA) solution for 60 min and then washed with 200-proof ethanol (VWR, USA). These parts are allowed to dry in ambient conditions to remove ethanol before assembly. The cleaned and assembled parts are then filled with a 2.5% (w/v) solution of Pluronic F127 (Sigma-Aldrich, USA) for 10 min to pre-condition the setup and prevent the agglomeration of yeast cells within the micro-cross, before syringes filled with the oil and monomer phases are attached as shown in Fig. S1†. The syringe pumps are started and droplet formation allowed to reach equilibrium before the UV lamp is turned on, and capsules may then be collected at the outlet. The prepared capsules are washed with deionized water to remove any oil and unreacted reagents before use in experiments.
For all experiments, a control sample of ultrapure water spiked with Pb(NO3)2 in absence of yeast and hydrogels was measured to act as a reference for the initial Pb2+ concentration, c0, in the solution. Pb2+ removal was quantified by taking the ICP-MS measurements of the supernatants and subtracting from this the reference to determine the quantity of metal adsorbed by yeast biomass. Type I ultrapure water alone was also tested via ICP-MS to make sure that there was no Pb2+ present in the aqueous matrix. The amount of Pb2+ uptake from the yeast biomass was calculated using eqn (1):
(1) |
Equilibrium isotherm data are obtained as the q values measured after 1 d of contact of yeast biomass (m: 0.005 g) with aqueous solutions (0.2 L) of different initial Pb2+ concentrations (c0: 20, 40, 100, 200, 300, 500, 700 and 1000 ppb), respectively. ESI 1.6† describes the fitting of first-principles derived curves to kinetics data recorded at periodic intervals (i.e., 0 min, 5 min, 15 min, 30 min, 1 h, 2 h, 4 h, 8 h, 24 h) of contact with yeast biomass (m: 0.005 g) in aqueous solutions (0.2 L) with c0 of 100 ppb.
Nile Blue acrylamide (Polysciences, USA) was dissolved to obtain a 0.01 mg ml−1 solution in the monomer phase described previously, and polymerized into the hydrogel matrix to visualize it.
Samples stained using Calcfluor White and Nile Blue acrylamide were washed to remove any unbound cells and dye, and imaged using an Olympus FV1000 Multiphoton Laser Scanning Confocal Microscope with a 10× water immersion objective. A 720 nm laser was used to excite both dyes. Calcfluor White emission was measured in 460–500 nm and Nile Blue acrylamide emission was measured in 380–560 nm to account for local solvent variations.
The Leadmium Green AM dye (Invitrogen, Thermo Fischer Scientific, USA) was used to detect and image lead on yeast cells. It is a highly specific indicator that allows for the detection of nanomolar levels of lead in microbial cells. The reagent preparation, staining and imaging protocols were applied as suggested by the manufacturer.
Samples stained with Leadmium Green AM dye were imaged using a Zeiss LSM 980 with Airyscan 2 Laser Scanning Confocal Microscope with a 10× air objective and a 488 nm laser for excitation. Fluorescence was measured at 520 nm and longer wavelengths.
The compressive behavior of spherical hydrogel capsules is non-trivial due to a continuously increasing surface area of contact between the specimen and the testing punch during compression. Hertz solved this contact problem for linearly elastic materials, predicting that the force exerted by a spherical body under small deformation (%) can be expressed as:35,36
(2) |
E = 2G(1 + n) | (3) |
P(r) = EAHertz | (4) |
(5) |
The data in Fig. 4b and c are obtained in the initial range of 10% amplitude of the sample height, a regime in which Hertzian contact mechanics offers accurate predictions. The estimated effective elastic modulus, E, was 6.28 ± 0.63 MPa, as fitted using eqn (4). The maximum load before failure, Pmax was at 0.88 ± 0.04 N, while the amplitude at which all samples burst was at 80% of the total sample height.
Contaminated water containing lead at a concentration of 100 ppb is injected through the packed bed biofilter at a flow rate of 0.1 ml min−1 using a syringe pump. The flow rate is set so that the residence time/contact time (8.45 min) is similar to the contact time in typical water treatment facilities (∼10 min), while being at least double the yeast-laden capsule equilibration time (3.83 min, see Fig. 3f).
A FlexiForce piezoelectric force sensor connected to a National Instruments NI myDAQ Student Data Acquisition Device that interfaces with MATLAB Simulink is used to measure the pressure drop across the biofilter. First, the force exerted by the syringe pump on the syringe to flow water through the biofilter at the desired flow rate is measured. Then, the biofilter (including the syringe filters on either end) are removed to obtain the force contribution attributable to the remainder of the setup, and this contribution is subtracted to obtain the force needed to pump water through the biofilter. Using a similar approach, the contribution of each filter component may be obtained and accounted for. Finally, we obtain the relevant force requirement to be 178 gram-force or 1.7462 N, and the pressure drop across the packed portion of the biofilter as 29.646 kPa.
Yeast-laden hydrogel beads and capsules are synthesized using an off-the-shelf microfluidic device (‘micro-cross’, Fig. 2a). We start by preparing a monomer solution (light blue in Fig. 2a) containing PEGDA monomers dissolved in water. Lyophilized yeast powder (Fig. 2b) is suspended in the monomer solution using a small amount of surfactant (0.05% (w/w)) to stabilize the suspension. The monomer solution is processed in the microfluidics setup (Fig. 2a and S1†) to obtain monodisperse droplets by pinch-off. An extensive preconditioning of the setup and stabilization of the monomer solution enables us to achieve significantly higher yeast loadings inside the hydrogels compared to prior work (see Materials and methods), eliminating challenges associated with yeast cells blocking the micro-cross pores.34 A photoinitiator (PI) triggers the free-radical chain growth polymerization of the PEGDA dissolved in monomer droplets upon exposure to UV light, crosslinking the monomer into a solid gel. The photoinitiator may be dissolved either in (i) the monomer solution or in (ii) the oil phase (light yellow in Fig. 2a), to obtain either beads or capsules respectively.
In the first case, when the photoinitiator is dissolved in the monomer solution, the polymerization occurs in the entire bulk of the monomer-containing droplets, leading to the formation of solid hydrogel beads. In the second case, when the photointiator is dissolved in the oil phase, the polymerization begins at the oil-droplet interface where the photoinitiator and the PEGDA monomers are in contact. The reaction then slowly progresses into the interior of the droplets as the photoinitiator molecules slowly dissolve and diffuse from the interface into the monomer solution, leading to the formation of capsules. Since the polymerization reaction rapidly stops after UV exposure is terminated, it is possible to prepare capsules with tunable wall thickness by controlling the duration of the UV exposure. Here, the capsules have a wall thickness that is approximately 30 μm (see ESI 1.5†), which may also be tuned by changing the wavelength and intensity of UV light, the tubing material, and similar parameters.38,39 Capsules and beads prepared in this manner are washed with DI water to remove unreacted PEGDA and photoinitiator, and any unbound yeast. A picture of yeast-laden capsules prepared using this method is shown in Fig. 2c and S2†.
As shown in Fig. 2b, the diameter of individual yeast cells is approximately 5 μm. The mesh size of the prepared hydrogels was calculated to be 2.09 nm in the absence of yeast cells within the hydrogel matrix, and 2.03 nm if yeast cells are present inside the matrix, using a combination of swelling measurements and Canal-Peppas theory (see ESI 1.1 and 1.2†). Since the size of the yeast cells is much greater than the mesh size of the encapsulating hydrogel (∼2,500×), we can guarantee that the yeast cells are permanently trapped within the hydrogel and cannot escape in the water that is to be treated. Such an encapsulation approach, which does not require the creation of chemical bonds between moieties on the yeast surface and the hydrogel matrix is desirable to ensure minimal effects on the properties of the yeast cells. Confocal microscopy images in Fig. S3† indicate that the yeast cells are intact after the polymerization process, allowing effective encapsulation. Fig. S2† shows an unstained hydrogel bead containing stained yeast cells after resting in a water bath overnight. The absence of any stained free yeast cells in the fluid surrounding the bead also demonstrates effective encapsulation.
Fig. 2d and e are confocal microscopy images of the interior of yeast-laden hydrogel beads and capsules, respectively. Yeast cells (cyan) are seen to be uniformly distributed within the hydrogel bead, but not within the hydrogel capsule. The non-uniform distribution of cells within the yeast capsule is a combination of the settling of yeast-cells under the effect of gravity, and the adhesion of yeast cells to the inner surface of the capsule walls (yellow). However, a significant number of yeast cells may nonetheless be seen to be free of the capsule walls and mobile within the capsule. The capsule walls are solid and prevent the escape of yeast cells as previously described.
Yeast-laden hydrogel capsules after biosorption were stained with Leadmium Green AM to visualize lead within the capsules using confocal fluorescence microscopy. The acquired images clearly show lead bound on the encapsulated yeast cells (Fig. 3a), while the background hydrogel matrix is only weakly fluorescent, indicating the uptake of lead by the capsules, and that the majority of lead uptake is due to the yeast cells and not the hydrogel matrix.
Performing equilibrium experiments at varying initial lead concentrations (c0: 100–1000 ppb) allows us to construct isotherms (Fig. 3b and c) that can guide the design of larger scale filters. Fig. 3b shows the concentration of lead in the interior of empty hydrogel capsules and beads (chydrogel) against the concentration in the supernatant at equilibrium (ce). The data fit linear isotherms, as can be expected based on prior work that used hydrogels for water treatment30 and described in ESI 1.3.† Lead ions are seen to weakly partition into the hydrogels, which may be attributed to a combination of hydrogen bonding between the PEGDA hydrogel and water associated to the lead ions, and to weak van der Waals forces. The empty hydrogel beads were also seen to have a significantly higher internal concentration of lead than the empty capsules, and this difference can be attributed to the greater quantity of polymerized PEGDA to bind lead within the beads compared to the capsules (see ESI 1.3†).
The yeast-laden hydrogel beads and capsules have significantly higher affinity to lead ions compared to yeast-free blanks, as can be seen by comparing the magnitudes of data on the second y-axis of Fig. 3c to the data in Fig. 3b (also see Fig. 3d and e). The isotherms in Fig. 3c, shown for free yeast as well as yeast-laden hydrogel beads and capsules, indicate significant lead binding by yeast in all three cases (∼2% of the total mass of the yeast). Importantly, trapping yeast cells inside hydrogel capsules does not significantly affect their ability to bind with lead (only a ∼10% loss in capacity; c0 = 1000 ppb), while immobilization within hydrogel beads significantly reduces binding capacity (∼40% loss in capacity; c0 = 1000 ppb). This reduction in uptake capacity may be due to: (1) interactions between the hydrogel matrix and the yeast cell wall, outcompeting interactions between the functional groups present on yeast cell wall which are responsible for binding lead ions,1 or (2) the effect of the photoinitiator on yeast properties. Photoinitiators form free radicals when exposed to UV light, thereby triggering polymerization reactions. However, the same free radicals may also attack the yeast cells, damaging chemical moieties responsible for binding lead.40 Since hydrogel beads have a greater quantity of hydrogel matrix surrounding yeast cells (see ESI 1.4†) and are prepared by dissolving the photoinitiator in the same phase as the yeast cells (as opposed to capsules), both these effects which limit lead uptake may be expected to be more significant in beads than capsules, leading to the reduced capacity of beads compared to capsules seen in Fig. 3c.
The adsorption isotherms of yeast and yeast-laden capsules are not linear and seem to follow Langmuir's isotherm model (Fig. 3c).41 A similar effect was observed in prior work that used free yeast to bind lead.1 A non-linear shape is also apparent from the presence of a sharp peak in the plot of lead elimination against initial concentration (Fig. 3e; unlike the flat profiles from linear isotherms in Fig. 3d), a feature of Langmuir adsorption model, borrowed from the ideal adsorption theory of gases. The presence of a peak indicates the existence of an optimal initial lead concentration for water treatment in batch operations, but does not affect the design of continuous flow-through filters. If a linear isotherm is nevertheless fit to the data in Fig. 3c as a first-order approximation, we obtain a partition coefficient (ratio of internal to external concentration at equilibrium ((chydrogel/ce)), obtained as the isotherm slope) of ∼3000, which is much greater than those observed in hydrogels optimized for water treatment in prior work,30 indicating the superior binding of functional groups on yeast cells compared to traditional chelating agents and other synthetic moieties used to bind lead in these hydrogels. Interestingly, unlike yeast-laden capsules, yeast-laden hydrogel beads also have nearly linear isotherms, which may be explained by a combination of reduced capacity (ESI 1.3†), and greater binding of lead to the hydrogel matrix as a fraction of binding to the yeast cells.
Contact times in real-world adsorption processes for water treatment are limited (∼10 min),22,23 making it important to assess the rate of lead removal by free yeast and yeast-laden hydrogel beads and capsules. Fig. 3f shows the amount of adsorbed lead over time starting with an initial lead ion concentration, c0, of 1000 ppb. This kinetics data may be fit to an analytical expression based on first-order kinetics to obtain mass transfer rates that can guide the design of filters at scale (ESI 1.6 and 1.7†). The use of the first-order kinetics model has been previously validated in studies that separately examined the use of free yeast and pure hydrogels for lead uptake.1 Regression also yields time constants for the uptake process (0.88 min for free yeast, 3.83 min for yeast-laden capsules, and 19.57 min for yeast-laden beads). The removal of lead can be seen to be most rapid using free yeast, followed by yeast-laden capsules, and finally yeast-laden beads. These trends may be expected due to the increasing restrictions on yeast mobility and mixing as we shift from free yeast in water, to yeast in hollow hydrogel capsules, and finally to yeast completely immobilized inside solid hydrogel beads. The equilibrium time constants for yeast-laden capsules are significantly shorter than the 10 min contact times in real-world adsorption processes, which, combined with their high capacity for binding lead (>20 mg per g yeast) (Fig. 3c and e), makes them advantageous for large-scale application, such as in bioreactors for filtration.
We evaluated the effective elastic modulus (E) of the yeast-laden hydrogel capsules, and the maximum compressive load (Pmax) they can withstand before failure (bursting of the capsules). To achieve loading conditions similar to those during biofilter operation, we performed uniaxial, displacement-controlled, compression tests of the capsules in water, as shown in Fig. 4a (experimental details in ESI 1.8†). The compression tests showed a non-linear dependence between load (P) and displacement of the compressing punch (δ) (green data points in Fig. 4b). The load–displacement data can be fitted as P ∝ δ3/2 (black dashed line in Fig. 4b). Such a dependence is common in homogenous, isotropic, linear, elastic materials, such as cross-linked, synthetic hydrogels,44–46 tested under small deformations and quasi-static loading conditions, and can be described by the Hertzian model.35,36 Although the yeast-laden hydrogel capsules are not typical homogenous hydrogel materials, since their interior is hollow and contains yeast cells (Fig. 2e), E can still be approximated using the Hertzian model, given the observed, non-linear P ∝ δ3/2 dependence. By fitting the experimental data, while assuming a Poisson ratio (n) of 0.5, which is typical for such materials,37 we obtain E = 6.28 ± 0.63 MPa (Fig. 4c). The Pmax that the capsules can withstand without bursting is about 0.88 ± 0.04 N. The Hertzian model is used here to get a first approximation of E. In future efforts, E can be determined in a more accurate manner by solving the boundary element problem.47
Fig. 4 Mechanical testing of capsules and proof-of-concept biofilter. (a) Experimental setup showing uniaxial, displacement-controlled, compression tests of the hydrogel capsules in water. The metallic punch is used to compress the hydrogel capsule in the indicated direction (white arrow) while the load and the applied displacement are measured. (b) Load versus displacement experimental data show a P ∝ δ3/2 dependence. (c) Fitting of the experimental data using the Hertzian model provides an effective elastic modulus (E) of 6.28 ± 0.63 MPa. AHertz is the effective capsule area, described in eqn (5). (d and e) The proof-of-concept cm-scale biofilter (d) containing yeast-laden hydrogel capsules constructed for this study, and the breakthrough curve (e) showing the concentration of lead in treated water coming out (cPb2+) as a function of time of operation and amount of water cleaned. Reported concentrations are ± 0.7%. The initial concentration of incoming water is 100 ppb. The dashed line shows the USEPA action level for lead. |
As a proof-of-concept of the scalability of our approach, 1.6 g (or about 24600 capsules) of yeast-laden hydrogel capsules were packed in an empty syringe to prepare a simple biofilter (Fig. 4d), through which lead contaminated water can be continuously pumped through to treat it. The filter is operated to have a contact time of 8.45 min, which is representative of contact times in real-world adsorption-based water-treatment processes.22,23 Considering the operational parameters and capsule dimensions, we estimated a developed drag force (Fdrag) of ∼0.8 μN and a maximum stress (σ) of ∼4.00 Pa on each yeast-laden hydrogel capsule (ESI 1.8†). Given the mechanical behavior of the capsules, E = 6.28 ± 0.63 MPa and Pmax = 0.88 ± 0.04 N, there remains a substantial elastic range before approaching the failure limits of the capsules. As a result, it is highly unlikely that the capsules would undergo significant deformation or encounter structural failure within the biofilter, ensuring that they will retain their functionality throughout biofilter operation.
Indeed, the filter was continuously operated for a period of 14 days, cleaning water with an initial lead concentration of 100 ppb, during which period we did not observe any bursting of capsules. Fig. 4e shows the concentration of lead (cPb2+) in water after treatment using our biofilter as a function of time and the cumulative amount of water treated relative to the mass of the hydrogel capsules (mwater/mhydrogel). The 1.6 g biofilter is able to treat over 1.5 L of contaminated water to below the USEPA lead action level for a period of 12 days before it needs to be replaced. Increasing the mass of hydrogel capsules within the filter will increase filter lifetime, which is governed by the equilibrium isotherms and kinetics shown in Fig. 3, as described in ESI 1.7.†
The maximum water flow rate through the biofilter (Qmax) is limited by capsule failure due to pressure, and estimated using mechanical data (ESI 1.8†) to be 1.87 L s−1 or ∼160 m3 per day. To put this into perspective, the standard flow rate for a US household kitchen faucet is 0.18 L s−1.48 This indicates that our biofilter approach can be effectively scaled for use in household settings without compromising the capsules' structural integrity and performance. Furthermore, the derived Qmax aligns with the average wastewater flow rate of a municipal treatment plant that caters to a small community of roughly 400 residents.49 As such, our current biofilter approach could be scaled to accommodate communities of up to a few hundred individuals. Modifications in the yeast-laden hydrogel capsules' geometry, such as size and wall thickness, and adjustments in the hydrogel material properties can be implemented to meet the requirements of larger populations (≥400 people).
Previous attempts to scale-up biosorption using immobilized microbial cells have failed mostly due to chemical alterations of cell structures caused by immobilization agents, lack of mechanical robustness, and unfavorable solute mass transfer rates.21 In contrast, our approach successfully addresses these challenges, enabling yeast to perform nearly as effectively as in its free state while encapsulated. This achievement is primarily attributed to the minimal interaction between the carrier (PEGDA) and the biosorbent, (inactive, lyophilized yeast biomass), and the protection of yeast from chemical alteration. Such minimal interference represents a significant success of our work and is a critical step towards the scalability and commercialization of the proposed approach. Additional engineering experiments can enable the scale-up of this approach for larger industrial or municipal settings. Potential modifications in the yeast-laden hydrogel capsules' geometry, and adjustments in hydrogel's material properties can be explored to ensure structural and functional integrity under varying operational conditions and in unforeseen situations, such as abrupt changes in pressure, temperature, or flow rates. Additionally, conducting a techno-economic analysis to evaluate the commercial competitiveness of the scaled-up approach is essential for translating these findings into the market.
Substantial quantities of residual or surplus yeast are generated from fermentation industries, with over 50000 tons annually produced from beer production in the US alone.27,50 This is an extremely underutilized, low-value or even negative-value resource, not suitable as a human dietary supplement due to high levels of nucleic acids.27 In parallel, PEGDA is an inexpensive, non-toxic, easy-to-make hydrogel,51 which can also be renewably sourced, as poly(ethylene) glycol (PEG) can be derived from biobased sources, such as plant-based feedstocks.52,53 Combining these low-cost, easy-to-mass-produce materials can result in environmentally-friendly, locally sourced water treatment methods. The circular economy principles inherent in this approach not only reduce waste and environmental impact compared to conventional water treatment approaches, such as RO, but also create economic opportunities within the communities where these resources are available. Therefore, this approach has the potential to address environmental equity challenges, particularly in low-income areas and communities of color that have historically faced environmental pollution and limited access to clean water.54
Footnotes |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4su00052h |
‡ These authors contributed equally to this work. |
This journal is © The Royal Society of Chemistry 2024 |