aCollege of Aerospace Engineering, Shenyang Aerospace University, Shenyang 110136, China. E-mail: sauhansen@163.com
bHealth Service Department, Northern Theatre General Hospital, Shenyang, 110016, China
cSchool of Aerospace, Mechanical and Mechatronic Engineering, The University of Sydney, Sydney, NSW 2006, Australia
dSchool of Mechanical and Manufacturing Engineering, The University of New South Wales, Sydney, NSW 2052, Australia. E-mail: shuai.he@unsw.edu.au; shuhua.peng@unsw.edu.au
First published on 19th October 2024
Flexible and stretchable strain sensors have garnered significant interest due to their potential applications in various fields including human health monitoring and human–machine interfaces. Previous studies have shown that strain sensors based on microcracks can exhibit both high sensitivity and a wide sensing range by manipulating the opening and closing of randomly generated cracks within conductive thin films. However, the uncontrolled nature of microcrack formation can cause a drift in the sensor's performance over time, affecting its accuracy and reliability. In this study, by pre-defining the cracks, we introduce a novel resistive strain sensor with high sensitivity, excellent linearity, an ultra-low detection limit, and robustness against off-axis deformation. The sensor operates on a simple mechanism involving the modulation of ohmic contact within intricately designed conductive serpentine curves, which are encapsulated by pre-stretched thin films. This design facilitates a high gauge factor of 495, exceptional linearity (R2 > 0.98), and an ultra-low detection threshold of 0.01% strain. Moreover, it maintains performance integrity during off-axis deformations such as bending and twisting, features that are indispensable for accurately monitoring human motion. To explore practical applications, a driving scenario was simulated where a sensor array was positioned on the driver's neck. The sensor output was analyzed using machine learning algorithms to successfully determine the presence of driver fatigue. This demonstration underlines the potential of our sensor technology in applications ranging from healthcare monitoring to wearable biomechanical systems and human–machine interfaces.
New conceptsThis study introduces a novel resistive strain sensor that addresses key limitations in existing strain sensor technology, particularly the issue of performance drift due to uncontrolled microcrack formation. Unlike previous designs, this sensor employs pre-defined cracks within conductive serpentine curves, significantly enhancing the sensor's sensitivity, linearity, and robustness. The controlled microcrack formation allows for a high gauge factor of 495, an ultra-low detection limit of 0.01% strain, and reliable performance under off-axis deformations like bending and twisting. This innovative approach not only improves the accuracy and reliability of strain sensors but also expands their potential applications in fields such as healthcare monitoring and human–machine interfaces. The successful application of this sensor in detecting driver fatigue through machine learning further demonstrates its practical utility in real-world scenarios. |
In recent years, researchers have explored structural designs of sensor's conductive networks to enhance sensitivity and stretchability.23 Studies have identified microcrack structures as an effective tool for improving sensor sensitivity.24–28 Inspired by spider webs, Sun et al. developed a strain sensor that utilizes an Au/SWCNT crack structure.29 The rigid Au film undergoes significant resistance changes due to strain-induced cracking, yielding high sensitivity (GF = 7.1 × 104–3.4 × 106). An underlying layer of single-walled carbon nanotubes (SWCNTs) provides additional conductive pathways across cracks, allowing for a wide operational range (100% strain). Furthermore, Sun et al. deposited CNTs and AgNWs on electrospun TPU fiber mats and then applied pre-stretching to create a microcrack structure, which resulted in a sensor that maintained high sensitivity and a broad strain range (0–102% strain, GF = 691; 102–135% strain, GF = 2 × 104; 135–171% strain, GF > 11 × 104).30 While these sensors exhibit high sensitivity and can operate across wide ranges, their performance is hindered by the random formation of microcracks. This results in non-linear strain responses, complicating the accurate interpretation of data. Furthermore, with repeated stretching, sensors with microcrack structures may not return to their original states due to the development of additional cracks. Extreme stretching may worsen this issue, potentially leading to the complete detachment of conductive connections within the crack structures, ultimately causing sensor failure. Addressing these challenges is crucial for enhancing the reliability and durability of the sensors. Researchers have also experimented with pre-defined structural design to develop sensors with serpentine structures, seeking both high sensitivity and robust stretchability.31 Zhou et al. used a graphene nanoplatelets/multi-walled CNTs/silicone rubber hybrid conductive network to create a serpentine sensing layer, achieving a sensor with high sensitivity (GF = 6.3–2675.5) and up to 100% strain range.32 Although biomimetic serpentine designs enhance mechanical compliance and improve sensor stretchability, they still exhibit non-linear strain responses across their operative range. To mitigate electrical disturbance from off-axis mechanical loads in tension, Xu et al. designed a serpentine sensor using a composite conductive material (Ag/highly conductive carbon nanoparticles/Au/Ecoflex), resulting in an extensive operating range (>150% strain) but relatively low sensitivity (GF = 1.23–8.67).33 It is notable that the proposed serpentine geometry effectively mitigates resistance variation due to off-axis deformation. This is achieved by minimizing stress concentration during bending or twisting, as demonstrated by Lin.34 Despite these advances, achieving high sensitivity coupled with high linearity in strain sensors through serpentine structural designs remains a persistent challenge.
Here, we introduce a simple and effective method to prepare highly sensitive strain sensors with an ultra-low detection limit and excellent linearity based on pre-defined cracks. The superior performance of these strain sensors is achieved through the precise opening and closing of pre-formed serpentine cracks within a conductive thin film, which is supported by a pre-stretched elastic encapsulation layer. In particular, our sensors achieve a gauge factor of up to 495 within a 9% strain range. They also offer an ultra-low detection limit of 0.01% strain, making them ideal for monitoring subtle biosignals such as human wrist pulse. Our sensors demonstrate good mechanical robustness, with only 7.9% drift of peak signals observed after 2000 cycles of stretching and releasing at a peak strain of 2%. Importantly, they exhibit minimal sensitivity to off-axis deformations such as bending, ensuring high accuracy for strain sensing under complex deformation conditions. Additionally, the sensors maintain their function under extreme conditions, including resistance to salt spray, ultraviolet radiation, and humid-thermal environments. Furthermore, the potential of these strain sensors in monitoring human activity has been validated through simulations of driving scenarios. A machine learning algorithm was developed to evaluate neck movement in drivers, aiming to identify signs of fatigue. This illustrates a practical application of our sensors in wearable devices to effectively monitor human movement.
Fig. 1 Schematic illustration of the sensor manufacturing process by transferring the conductive thin film with serpentine cutting patterns onto the pre-stretched TPU substrate. |
The resistance change of our strain sensors was precisely controlled through the deliberate manipulation of pre-formed cracks within the conductive thin films. When these cracks were closed, the sensors exhibited a low resistance state because electrons could flow through the contacted and connected conductive pathways between short-circuited conductive serpentine strips. On the other hand, when the cracks were fully opened, the sensors demonstrated a high resistance state as the electrons had to flow through the extended conductive pathways (Fig. 2a). This simple mechanism allows for accurate and repeatable adjustments in resistance, making the sensors highly effective for precise strain measurements. As shown in Fig. 2b, the conductive thin film of TPU was cut into a serpentine pattern and encapsulated within a pre-strained elastic membrane. This design makes the sensors mechanically robust and resistant to environmental interferences, enhancing their durability and reliability under various conditions. It can be seen that by applying a strain as small as 0.05%, the opening of cracks became visible in conductive thin films (Fig. 2b). The strain sensor with its multilayered structure was well bonded and tolerant to various mechanical deformations, such as stretching, bending, and twisting (Fig. 2c). This robust construction ensures reliable performance and durability under different types of mechanical stress. In addition, the microstructure of conductive films based on TPU was extensively characterized using SEM. Fig. 2d shows the SEM image of the top surface of the conductive TPU film, revealing a smooth surface after hot pressing, which effectively eliminated voids and defects in the original 3D-printed film. Fig. 2e displays SEM images of the fractured surface of the conductive TPU film, where the distribution and presence of conductive particles are clearly observable, highlighting the structural integrity and conductive pathways within the material.
The serpentine patterns of the conductive layer, determined by various cutting parameters, have a direct impact on the sensing performance of our strain sensors. We focus on two main parameters: the pitch length between serpentine curves (p) and the width of these curves (w) to evaluate their effects on sensor performance. Initially, we investigated sensors with the same width (w = 15 mm) but different pitches under stretching through finite element simulation. For simplicity, we modelled four serpentine curves for each of the three parameter sets (p = 0.5, 1 and 2 mm, respectively). We recorded the states of the sensors with different p at different strain levels (Fig. S2, ESI†). Additionally, we measured the contact area of one crack in each sensor (Fig. S3, ESI†) and it indicated that the cracks for the sensor with larger p were separated at smaller strain. The results aligned with the observed trends in electrical resistance response as shown in Fig. 3a. For the strain sensor with p = 2 mm, the sensing range was smaller because the cracks were fully opened at 3.6% strain and no further resistance changes would be observed afterwards. As the p decreased to 0.5 mm, the cracks were fully opened at 14.8% strain. As such, the sensor with p = 0.5 mm showed the largest sensing range of 14.8% strain. Meanwhile, under the same strain level, the strain sensor with smaller p has the higher crack density, which contributes to larger resistance changes and hence higher sensitivity. As a result, the strain sensor with p = 0.5 mm showed the best sensing performance in terms of sensitivity (1154.7) and a sensing range of 14.8%. However, achieving high-quality cutting with p = 0.5 mm was challenging and strain sensors with p = 1 mm were selected for further studies in this work.
As for the strain sensors with fixed p = 1 mm, both sensing range and sensitivity increased when the width w increased. As shown in Fig. 3b, by increasing w from 5 to 30 mm, the corresponding sensitivity increased from 179 to 983 and the sensing range increased from 3.5% to 12.5%. To account for these results, we theoretically derived the resistance response trends of sensors with different widths at the same spacing using the formula R = ρL/A, where ρ is the resistivity of the material, L is the length of the sensor, and A is the cross-sectional area of the sensor along its length. The width w was varied among three specific values while maintaining the same length L and thickness for all sensors. A larger w results in a larger cross-sectional area A, thus lowering the resistance R. Consequently, the sensor with a width of w = 30 mm has the largest cross-sectional area, resulting in the smallest initial resistance R0, which is advantageous for increasing the rate of resistance change. Moreover, a larger crack cross-sectional area also increases the separation area of the sensor under stretching strain, similarly aiding in increasing the rate of resistance change. Combining these two factors, the results align with the actual trends in electrical resistance response, as shown in Fig. 3b, where the configuration with w = 30 mm and p = 1 mm showed the greatest sensitivity, that is, at the same pitch, a larger width results in a greater rate of resistance change.
It is noteworthy that even though the model with parameters w = 15 mm and p = 0.5 mm exhibited the highest strain sensitivity, its linearity was significantly lower compared to the model with parameters w = 15 mm and p = 1 mm. Additionally, considering its suitability for conformal monitoring of movements around fingers, wrists, necks, and other body joints, the sensor with w = 15 mm and p = 1 mm was selected for further performance evaluations. Finite element simulation analysis was performed on the sensor model to capture the opening of serpentine patterns after applying 20% strain.
As depicted in Fig. 3d, the selected sensor with p = 1 mm and w = 15 mm exhibited an excellent linear response up to 8.7% strain, with a high gauge factor of 495. The sensor's linearity, indicated by the coefficient of determination (R2), was derived from a linear regression of resistance data from 0% strain to the saturation point, marked by the yellow line in Fig. 3d. The sensor's sensitivity, defined as (ΔR/R0)/Δε, was calculated from the slope of the linear fit. During testing, the sensor was stretched at a constant speed of 5 mm min−1 using a universal testing machine, achieving a sensitivity of 495 and an R2 value exceeding 0.98 (Fig. 3d). The resistance changes saturated around 10% and did not show any increase even when the applied strain was further increased. This is due to the total separation of the previously contacted conductive serpentine curves, and afterwards, the conductive thin film simply extended without further changes in resistance. Fig. 3f presents a comparison of the gauge factor and the linear sensing range of our newly developed sensors, with those reported in the recent literature11,18,25–28,35–42 using other conductive nanocomposites. Table S1 (ESI†) also presents comparisons with previous works in sensing mode.19,43–50 We further explored the mechanical and resistive hysteresis of the sensor under varying stretching speeds of 1 mm min−1, 5 mm min−1, and 10 mm min−1 and the corresponding results are given in Fig. S4 (ESI†) and Fig. 3e. The average mechanical hysteresis rate was 30.76%, and the average resistive hysteresis rate was 16.43%, both of which are comparable to the values of strain sensors reported in the literature.51,52 The mechanical robustness of our sensor is demonstrated by its capability to withstand 2000 cycles of 2% strain and 8% strain with a minimal signal drift. As illustrated in Fig. 3g, the average peak value of the final ten cycles was only 7.9% lower than that of the initial ten cycles. Fig. S5 (ESI†) also illustrates that the average peak value of the final ten cycles was only 7.9% lower than that of the initial ten cycles. The sensor was also tested for its ability to maintain resistance under prolonged stretching. Initially, the resistance peaked, then steadily decreased, and stabilized around 4.8 seconds with a 6.8% decrease in the rate of resistance change. Fig. S6 (ESI†) displays the resistance response of the sensor when subjected to a static 8% strain for more than 10 minutes. The excellent static stability is also illustrated by stretching the sensor by 2.5%, 5% and 10% of the strain, with the electrical signals in Fig. S7 (ESI†) showing little overshoot and rapid stabilization. Fig. S8 (ESI†) shows the dynamic stability by applying cyclic 5% strain with the frequency ranging from 0.1–0.5 Hz.
The sensor is capable of distinguishing different levels of strain and has a very low detection limit of 0.01% strain. Fig. 4a–c shows the resistance changes for the strain sensor under different levels of strain, clearly demonstrating that for strains above 0.1%, the resistance change signals are highly recognizable. Even for a very subtle strain of 0.01%, a significant resistance change signal with a signal-to-noise ratio (SNR = 3.344) was validated. This makes the sensors highly potent for monitoring delicate biosignals such as pulse and respiration which are closely related to human health conditions. The ultralow detection limit was also verified by incrementally stretching in steps of 0.03% strain. The resistance changes closely followed the input strain patterns during the stretching-hold process and the subsequent release-hold process (Fig. 4d). When the sensor was pre-stretched to an initial strain of 5%, additional 1% strain cycles were then applied. The sensor demonstrated its high sensitivity by accurately detecting the 1% strain superimposed on the initial deformation, as shown in Fig. 4e. Furthermore, our sensor demonstrated similar detection capability even under a smaller strain regime, where it was pre-stretched to 1% and then ten cycles of 0.1% strain were applied. The sensor was again able to precisely recognize the 0.1% strain fluctuations, as depicted in Fig. 4f. These results clearly demonstrate the sensor's remarkable detection capabilities, even at low strain levels, highlighting its potential for applications requiring fine strain resolution.
Due to the sensor's excellent capability of detecting subtle strains, it was utilized to monitor biological signals, specifically the pulse on a healthy male's wrist (Fig. 4g). The sensor was firmly attached to the wrist and it successfully captured the pulse waveform (Fig. 4h). The inset in the upper left corner showed distinct phases of the cardiac cycle: the percussion wave (P wave), tidal wave (T wave), and diastolic wave (D wave). Another inset in the upper right corner displays a frequency-amplitude curve derived through Fast Fourier Transform (FFT) analysis, confirming a pulse rate of 79.8 bpm, consistent with normal heart rate values.
Another important characteristic of this sensor is its tolerance to overstretching beyond its working strain range. As shown in Fig. 4i, the sensor can retain its strain sensing capability even after being stretched over 50%, which is significantly beyond its working range of up to 10% strain. This is attributed to its unique serpentine cutting pattern. As previously discussed, although the contact area of neighboring serpentine conductive strips completely separates after 10% strain, the structure and conductive pathways of the serpentine conductive thin films remain intact even at strains over 50%. After releasing the overstretched strain, the separated serpentine conductive strips make contact again, thereby restoring the sensor's sensing capability. This unusual ability to tolerate high levels of strain significantly enhances the robustness of our sensors. They can maintain their sensing capability even when subjected to overstretching during the mounting or removal processes. This resilience ensures reliable performance and durability, making the sensors suitable for various applications where they might experience mechanical stress beyond their normal operating range.
Our strain sensors also demonstrate an impressive capability to maintain a minimal bending response, ensuring that they can deliver highly accurate strain sensing even under complex deformation conditions. This makes them exceptionally reliable for applications requiring precise measurements in environments where traditional sensors might struggle to perform consistently. As shown in Fig. 5a, under cyclic stretching with a 10% strain, our sensors exhibited a substantial resistance change of 4000%. In contrast, during bending tests at a 45-degree angle, the resistance change was only 20%. This indicates that bending generates a negligible signal compared to stretching. These results highlight the sensor's robustness in maintaining accurate strain measurements even under significant deformation conditions, with minimal interference from bending. The sensor demonstrated exceptional resilience to significant impact loads. As illustrated in Fig. 5b, when subjected to impact loads from a drop hammer with energies ranging from 1 to 5 J, the sensor remained undamaged and its initial resistance was restored post-impact. However, at an 11 J impact, the resistance change rate increased to 6.5 times the average rate observed at lower energy impacts, and it did not return to its initial value, indicating structural damage. The inset in Fig. 5b shows resultant surface depressions on the sensor and noticeable deformation on the aluminium plate. Despite this structural damage, the peak damage response was only 4.3% of the peak response observed during linear stretching.
Our sensor can accurately detect strain even when subjected to combined strain and torsional deformations. Fig. 5c illustrates the sensor's response to continuous torsional motion ranging from 0 to 90 degrees. The average peak response observed over five trials was less than 1.5% of the peak response recorded during tensile stretching at 10% strain. This highlights the sensor's minimal sensitivity to torsional movements. Additionally, in a related set of experiments shown in Fig. 5d, the sensor was initially set to torsion angles of 0°, 30°, and 45° before being subjected to a 20% tensile strain. The results from these experiments indicate a slight decrease in the resistance response as the initial torsion angle increased. Particularly, the resistance change rate at a 45° torsion angle decreased by approximately 6.3% compared to the resistance change rate at a 0° angle. These findings collectively underscore the sensor's limited responsiveness to torsional strains and its exceptional ability to accurately monitor strain information under complex deformation conditions. For joints that experience complex deformation, such as the rotational and bending movements of the wrist, it is crucial to precisely monitor strain information to ensure an accurate assessment of mechanical stresses. These data are essential for understanding the biomechanical behavior of the joint, preventing potential injuries and optimizing the design of assistive devices, such as orthoses or prostheses, to provide better support and enhance overall mobility.
In addition to its minimal interference from bending and torsion, our sensor can maintain its strain sensing capability under various extreme environmental conditions. To investigate the potential effects of human sweat corrosion on the sensor, a salt spray environment test was conducted, as shown in Fig. 6a. Over a period of 7 days, the sensor's sensitivity and linearity in the salt spray environment were assessed. The results indicated that the sensing performance remained unaffected despite prolonged exposure to the corrosive environment. The inset images in Fig. 6a show the strain-resistance change rate curves before the test, as well as at 3 and 7 days post-exposure. These curves demonstrate consistent sensor performance, underscoring its robustness and reliability under conditions that simulate human sweat corrosion. Additionally, the sensor was subjected to intense ultraviolet (UV) light to evaluate its robustness under such conditions. Fig. 6b displays the sensitivity and linearity of the sensor over a week of UV exposure, supplemented by inset images showing the strain-resistance change rate curves before exposure, and after 3 and 7 days. Fig. 6c quantifies these observations, showing a decrease in the resistance change rate at a saturation of 4.8% post salt spray testing and 4.6% post UV exposure after 30 days. This indicates the superior resistance of the sensor to both salt spray and UV aging. Moreover, the sensor was also subjected to humid-heat environmental testing, with results presented in Fig. 6d. This test tracked the resistance change rate as a function of temperature under humidity levels of 20%, 40%, 60%, and 80%. The change in resistance was most significant at 60% humidity, where the resistance response at 80 °C amounted to only 3.6% of the peak value observed during linear stretching. These results demonstrate the sensor's robust performance under humid-heat conditions. Fig. 6e displays the appearances of sensors: an untested sensor (left), a sensor subjected to 30 days of salt spray environmental testing (middle), and a sensor after 30 days of ultraviolet environmental testing (right). Additionally, three dashed boxes on the right side (colored red, yellow, and blue) provide magnified views of each sensor, respectively. The visual comparison reveals minimal changes in appearance after 30 days in the salt spray environment, whereas the sensor demonstrates evident aging and yellowing after the same period under UV light. These findings collectively highlight the sensor's exceptional durability and reliability under various harsh environmental conditions, including salt spray, UV exposure, and humid-heat environments.
Building on the excellent performance of our sensors, they exhibit significant potential for applications in human health monitoring and human–machine interaction. These sensors were affixed to various locations on the human body to monitor a wide range of physical movements, demonstrating their versatility and effectiveness. Fig. 7a and b show the resistance responses of sensors placed on the wrist and knee at bending angles of 0°, 45°, and 90°. These figures clearly capture the biomechanical dynamics of the wrist and knee joints, making the sensors highly useful for rehabilitation purposes. The results indicate that the sensors can accurately measure and track joint movements, providing valuable insights for developing personalized rehabilitation programs. To further evaluate the sensors’ capability for hand gesture recognition, five strain sensors were individually attached to each finger of a hand. The sensors recorded responses to three distinct gestures: ‘OK,’ ‘Yeah,’ and ‘Thumbs Up.’ Fig. 7c demonstrates that the sensors’ outputs varied distinctly with each gesture, confirming their ability to accurately track and recognize complex hand movements. This functionality is particularly beneficial for facilitating communication among individuals with speaking difficulties, offering them an effective alternative means of expression.
Our sensor technology can discover new applications by integrating with emerging technologies such as machine learning. One compelling example we demonstrated is monitoring the driver's status by placing three sensors at the back of the driver's neck. As shown in Fig. 7d, these sensors monitored subtle neck movements in six individuals, collecting a substantial dataset of 859 labeled data points. The data were normalized for two simulated states: normal driving and fatigued driving. This dataset was analyzed using a fully connected feed-forward neural network implemented in MATLAB. The network utilized a logistic sigmoid activation function and a softmax output layer for binary classification, optimized iteratively using a scaled conjugate gradient method. The network architecture included two hidden layers with 25 and 20 neurons each. To enhance efficiency, graphical output was omitted during the model's training phase. The effectiveness of the model was validated using a confusion matrix, which demonstrated its ability to differentiate between non-fatigued and fatigued driving states with 100% accuracy based on the sensor data. This result confirms the robust functionality of the sensors in real-world applications, particularly in safety-critical scenarios such as driver fatigue detection.