DOI:
10.1039/D3NA00507K
(Review Article)
Nanoscale Adv., 2023,
5, 5997-6016
Gas nanosensors for health and safety applications in mining
Received
11th July 2023
, Accepted 6th October 2023
First published on 24th October 2023
Abstract
The ever-increasing demand for accurate, miniaturized, and cost-effective gas sensing systems has eclipsed basic research across many disciplines. Along with the rapid progress in nanotechnology, the latest development in gas sensing technology is dominated by the incorporation of nanomaterials with different properties and structures. Such nanomaterials provide a variety of sensing interfaces operating on different principles ranging from chemiresistive and electrochemical to optical modules. Compared to thick film and bulk structures currently used for gas sensing, nanomaterials are advantageous in terms of surface-to-volume ratio, response time, and power consumption. However, designing nanostructured gas sensors for the marketplace requires understanding of key mechanisms in detecting certain gaseous analytes. Herein, we provide an overview of different sensing modules and nanomaterials under development for sensing critical gases in the mining industry, specifically for health and safety monitoring of mining workers. The interactions between target gas molecules and the sensing interface and strategies to tailor the gas sensing interfacial properties are highlighted throughout the review. Finally, challenges of existing nanomaterial-based sensing systems, directions for future studies, and conclusions are discussed.
1. Introduction
Gas sensors are an integral part of health and safety monitoring in many industrial sectors ranging from healthcare to manufacturing and defense.1 The working environments in underground mines are known for their complexity and harshness with some hazards arising directly from various combinations of gaseous chemicals.2 The dynamic and tough mining environments pose serious challenges in maintaining occupational health and safety (OHS) of the workers in mines. A fatality rate of 2.9 per 100000 was reported for Australia's mines in 2019.3 This number represents the fourth highest rate among various industrial sectors.3 Sustainable growth of the mining sector, which accounts for AUD$105 billion revenue for coal mines in Australia from 2012 to 2022 alone,4 requires investment in OHS monitoring technology and infrastructure of underground mines.
Since the emergence and commercial usage of gas sensors, a variety of gas sensing modules, configurations, and sensor/analyte interfaces have been introduced and their development remains at a fast pace.5 Advanced placeable, wearable, and implantable sensor technologies will play an increasingly important role in the future as envisioned by various health and regulatory organizations, employers, and researchers.6
Given the critical role of the sensing element in gas sensor performance, many of the efforts in gas sensor development are concentrated on exploring new sensing or transducer materials, for example, the metal–organic frameworks (MOFs).7 Commercial gas sensors generally contain bulk or thick-film sensing materials with limitations on the size, weight, performance, and power consumption of the overall sensor device.8 Replacing traditional sensing materials with nanomaterials thus promises to significantly reduce the size, weight, and power consumption in the next generation of nanomaterial-enabled gas sensors. Gas sensor miniaturization will drive new consumer products in portable or wearable electronics, internet-of-things (IoTs), and multi-gas detection technology. Sensors with sensing elements at the nanometer scale, i.e., nanosensors, promise improved response time, sensitivity, and limit of detection (LOD).1,9,10 The recent strides in the design and implementation of nanomaterials have propelled significant progress in nanosensor technology, owing to the emergence of diverse classes of nanostructured interfaces. Noteworthy examples include nanoarchitectonic materials,11,12 few-layered 2D structures,13,14 1D semiconductors,15,16 silicon carbide,17,18 and magnetic systems,19 as well as mesoporous20 and nanoporous21 materials. These nanosensing interfaces have demonstrated remarkably enhanced performance.
To date, a variety of nanomaterials have been employed to construct gas-sensitive interfaces in different configurations and with specific characteristics depending on the type of signal readouts.5,9,22–24 Gas sensing performance of these nanosensors is optimized by the size and shape,25 chemical composition,26 and interfacial assembly27 of the nanomaterials.
Despite the development of a wide range of nanomaterials for gas sensing, our understanding of the underlying gas detection mechanisms of nanomaterials is incomplete and therefore warrants further research.
The present review aims to provide a comprehensive overview of the current understanding of the operational principles and detection mechanisms of different gas sensing systems, along with a discussion of their advantages and disadvantages for their potential applications in the mining industry. To that end, we aim to capture the essential chemical environments in underground mines as well as current gas sensor technologies deployed for mine health and safety monitoring and unmet gas sensing needs of the mining industry. The role of nanomaterials in advancing such gas sensors toward fulfilling the needs of the mining sector for health and safety monitoring is highlighted in selective case studies. The interactive pathways between the nanomaterials incorporated into different sensing interfaces and the target gaseous analytes are examined to bring forth directions for developing nanosensors specific to the mining sector. Finally, gaps in the literature and motifs for future developments are provided.
2. Sensing modules of nanomaterial-enabled gas sensors
Nanomaterials have been incorporated into gas sensing interfaces based on different sensing modules.1,5 Depending on the combinations of the nanosensor material type and the target gas molecules, different sensing technologies have been introduced.28 In this section, we provide a summary of common sensing modules and the related sensing mechanisms.
2.1. Resistive gas sensors
Resistive gas sensors are among the most well researched sensors.29 The operational principle of these sensors is based on a change in the electrical resistance of the sensing material upon exposure to the target gas molecules. The resistance change is induced by chemisorption or physisorption of gas molecules on the surface of the sensing material.30,31 Metal oxide semiconductors (MOSs) are the most common type of nanomaterials used in chemiresistive sensors owing to their unique electronic structures and high numbers of active sites.29,32 MOS-enabled nanosensors detect gases based on the adsorption and ionization of oxygen molecules in a typical temperature range of 200–400 °C.33 The oxygen ionization process leads to the removal of electrons from MOSs, forming an electron depletion layer (EDL) and a hole accumulation layer (HAL) in n-type and p-type semiconductors, respectively.34 Depending on the type of target gas molecules that interact with such electronic structures, electrons are either injected into MOSs (in the case of reducing gases) or removed from MOSs (in the case of oxidizing gases). For instance, in an n-type MOS, exposure to reducing gases leads to a decrease in the width of the EDL and a reduction in resistance; meanwhile, the interaction between oxidizing gas molecules and an n-type MOS increases the width of the EDL and resistance. A reduction in the concentration of charge carriers and increase in resistance are observed after the adsorption of reducing gas molecules on a p-type MOS. On the other hand, subjecting a p-type MOS to oxidizing gases results in an increased HAL width and a reduced resistance.35–37 MOS nanosensors are promising for gas detection in harsh environments such as underground mines. Their drawbacks include high operating temperature and limited lifetime of use due to surface poisoning.38
2.2. Gas sensors based on field-effect transistors (FETs)
A typical FET device consists of a sensing layer placed between a drain and a source terminal. An input voltage is applied to the sensing interface through a dielectric layer and a third gate terminal. In the context of gas sensing, the drain-source current is measured upon the interaction of the sensing layer with the target gas molecules at a given gate voltage.39 The flowing current can be modulated by adjusting the magnitude of the applied gate voltage, enabling a tuneable sensitivity for measuring different concentration levels of gas molecules.40 A wide variety of nanomaterials such as metallic41 and organic42 semiconductors, polymers,43 graphene,44 and carbon nanotubes (CNTs)45 have been used to construct FET nanosensors.46 FET-based gas sensors have several advantages over others including cost-effectiveness, low power consumption, and facile fabrication and miniaturization.47
2.3. Optical gas sensors
The operational mechanism of optical gas sensors is based on changes in the optical properties of the sensing nanomaterial after its exposure to gas species of interest. In this case, the sensing signal can be reflectivity, colorimetry, fluorescence, surface plasmon resonance (SPR), Raman scattering, absorbance, or refractive index.48 Optical gas sensors operate at room temperature and offer high chemical selectivity and fast response. However, challenges in integrating optics into electronic devices and their moderate sensitivity have restricted the real-world applications of optical gas sensors.49
2.4. Gas sensors based on quartz crystal microbalance (QCM)
Such sensors work based on the piezoelectric effect of quartz crystals where an interfacial mass adsorption perturbs the resonance frequency of the crystal. Therefore, the change in the resonance frequency upon exposure to target gases is recorded as the analytical signal.50 The sensing mechanism in QCM sensors is based on the adsorption and desorption of gaseous analytes, leading to a change in interfacial mass and resonance frequency. The integration of nanomaterials into QCM-based interfaces amplifies the available active sites for adsorption and desorption processes.50 To tailor gas-QCM interfacial interactions and improve the selectivity and sensitivity of the QCM gas sensors, a variety of functional coatings have been applied to QCM sensor surfaces.51–53 Compared to other types of sensors, QCM sensors are compatible with a wider range of nanomaterials. These sensors operate at room temperature and require low power for operation. However, improvements in their sensing stability, reproducibility, and handling are required to meet the needs of the market.53
2.5. Electrochemical gas sensors
Depending on the electrochemical activity of the target gas molecules, this type of gas sensor employs different electrochemical techniques for quantification, such as amperometry, potentiometry, and electrochemical impedance spectroscopy (EIS).54 In these sensors, gas molecules diffuse through a membrane into a solid or liquid electrolyte toward the surface of a working electrode (WE), where an electrical input is applied to track subsequent electrical output events. The output current, due to the redox reaction of a target gas at the WE, is recorded as the sensing signal. EIS is an ultrasensitive and a more universal electrochemical sensing module that responds to changes in the interfacial chemistry of the WE upon gas adsorption. Interactions between the dissolved gas species and the WE surface result in variations in the impedance component, which can be used as the sensing signal.55 While electrochemical gas sensors offer high selectivity and sensitivity, they suffer from temperature sensitivity and leakage of liquid electrolytes. To enhance the performance and durability of such sensors, nanomaterials have been exploited to modify the WE surface for increasing the electrochemically active interface.56 Nanostructures have also been integrated to such systems as solid electrolytes to improve their durability and robustness.57
Apart from the sensing modules discussed above, there are other types of gas sensors such as surface acoustic wave (SAW),58 catalytic combustion,59 and thermal conductivity60 gas sensors. In brief, in SAW sensors, the properties (i.e., amplitude or velocity) of an acoustic wave propagating through a material, are tracked upon the sensor interactions with the gas molecules.58 Catalytic combustion-based gas sensors use a sensing element with catalytic activity dispersed within a supporting matrix. Such sensors operate at an elevated temperature where the combustion of flammable gases, such as methane and hydrogen, further increases the temperature, resulting in a change in the sensor's resistance.59 Thermal conductivity gas sensors work based on measuring heat loss (change in resistance) upon the adsorption of gases with a lower thermal conductivity than air. The measurements are accomplished using a Wheatstone bridge circuit against a flow of a reference gas on a second sensing element.60Fig. 1 outlines the major sensing methods used to detect critical gas molecules relevant to mining safety, as well as the contribution of nanomaterials in enhancing the performance and applicability of these sensors.
|
| Fig. 1 Schematic representation of a typical nanosensor interface, the gases of concern in coal mines, the common sensing methods utilized for mine monitoring, and the advantages of nanosensing interfaces. Nanoparticles and nanowires (grey objects) are predominantly used in nanosensor interfaces. | |
3. Gas sensing needs in underground mines
As shown in Fig. 2A, it is challenging to ensure health and safety of mining environments because of the size and shape of the underground roadways, typically with lengths of tens of kilometers and widths of several meters. Ideally many environmental factors, including the amount of gas, water, and dust, should be monitored continuously at many places throughout the tunnel, which demands high sampling density and number of sensor devices. Current mine environmental monitoring is typically conducted in a sparse and manual way due to the lack of advanced, reliable, and economical sensing techniques.61
|
| Fig. 2 (A) Illustration of a typical underground coal mine. (B) Typical devices carried by miners. Reprinted with permission from ref. 61. | |
The two major underground coal mining methods are the room-and-pillar (also referred to as the Bord-and-Pillar) method and the longwall method.62 In room-and-pillar mining, the coal is continuously cut and loaded onto a face transport vehicle (e.g., a shuttle car) by a miner. In longwall mining, a longwall shearer does the same job, cutting and loading the coal onto a face conveyor on which it rides. The more recent longwall mining technology accounts for one third of all underground coal production. It is a continuous process using a rotating shear on the mining machine to cut into a block of coal. The coal is then removed by a conveyor from the mine. Desirable requirements relevant to the sensor technology include (1) remote management of the entire monitoring system including communication and routing mechanisms under all conditions and (2) in situ interactions with stationary sensors deployed on the walls, poles, and floors as well as mobile sensors integrated into devices carried by the miners (Fig. 2B).
The application of gas detection technology is significantly influenced by the challenging operating environment of gas sensors in underground coal mines. This environment is characterized by several factors, including wide fluctuations in atmospheric pressure, large temperature and relative humidity variations, high concentrations of dust particles, and strong electromagnetic interference. Additionally, there are other factors such as coal-rock collapse, mechanical vibrations, and unexpected impacts, which have varying degrees of impact on the gas detection devices. The production safety of underground coal mines is mainly dependent on the environmental conditions of the mines. The monitoring and maintenance system using traditional wire communication suffers from many shortcomings including high construction cost, damage of communication cables, high fault rate, inconvenient system maintenance, and others.63 As a result, a wireless sensor network (WSN) has emerged as an essential technology for continuous monitoring of the workplace environment in underground coal mines.64 Wireless operations impose strict requirements on power consumption of sensor nodes.65,66 A low degree of informationization and regular calibration requirements are the other main limitations in current coal production safety technologies.67 Therefore, it is of great significance to develop low-cost, low power consumption, and maintenance-free gas sensors based on new technology to detect various poisonous and inflammable gases.
The gases of relevance for coal mine explosion or fire are methane (CH4), carbon dioxide (CO2), carbon monoxide (CO), and oxygen (O2).68 The gaseous environments more relevant to iron and other metal mines can be found elsewhere in the literature.69 CH4, acetylene, hydrogen, and higher hydrocarbons are considered nontoxic but explosive. CO2, radon, and its daughter products are toxic. CO, sulfur dioxide, nitrogen oxides, and hydrogen sulfide (H2S) are acutely poisonous. Other impurities of concern are coal dust and water vapor.66
Underground fires can be caused by open flames, spontaneous combustion of coal, electricity, friction from cutting and drilling, welding, blasting, explosion, etc.66,70 Spontaneous combustion of coal is the main cause of fire in underground coal mines and ideally should be continuously monitored. Commonly used gas ratios and indices extracted from gas monitoring data to predict spontaneous combustion of coal are Graham's ratio, Young's ratio, and the oxides of carbon ratio, and the C/H ratio. Graham's ratio is the most widely used metric and is given by the ratio of CO produced to the oxygen consumed (ΔO2) in the process of spontaneous combustion. Graham's ratio = (100 × CO)/ΔO2. Young's ratio is given by the ratio of CO2 produced to O2 consumed. Young's ratio = (100 × CO2)/ΔO2. An increase in Young's ratio and decrease in Graham's ratio as a result of CO burning indicates the progress of fire from smouldering to open flame. The oxides of carbon ratio is defined as the ratio of the difference in the final and initial concentrations of CO and CO2. CO/CO2 ratio = (final CO − initial CO)/(final CO2 − initial CO2). The advantage of using this ratio is that it is uninfluenced by the inflow of air, nitrogen, or CH4. This ratio is a more sensitive indicator of fire than Graham's ratio. The C/H ratio is used to predict the intensity of fire along with O2 deficiency. C/H ratio = 6(CO2 + CO + CH4 + 2C2H4)/2(ΔO2 − CO2 + C2H4 + CH4) + H2–CO. For more information on these and other fire gas indices and how they are used to predict underground coal fires, refer to the excellent review by Muduli et al.66 While smoke detectors are a mature technology, work by Gottuk et al. showed that combining conventional smoke detectors with CO sensors can reduce false alarms while increasing fire detection sensitivity.71
The underground coal mine explosions are caused either by ignition of CH4 or coal dust or a combination of them. The release of inflammable gases from coal, CH4 and other minor gases (firedamp) can cause explosions. Real-time monitoring of CH4 and O2 is therefore critical for the detection and prevention of underground explosions. When CH4 buildup in an underground coal mine reaches a certain concentration range, 5–15%, explosion can be initiated by the presence of a small heat source. The minimum concentration of CH4 (in air) of this explosive concentration range is termed the lower flammability limit (LFL) (or the lower explosive limit (LEL)). The maximum concentration of this range is called the upper flammability limit (UFL) (or the upper explosive limit (UEL)). When CH4 concentration falls below the LEL, the amount of CH4 becomes too low to ignite. Similarly, the amount of O2 becomes too low when the CH4 concentration reaches above the UEL and no ignition occurs.72 Kundu et al.73 reviewed and summarized the explosion concentration range at different temperatures and pressures as well as the influence of various obstacles and geometries on explosions in an underground mine.73 CO and O2 sensors at the inlet and outlet of a working panel together with temperature sensors placed at the pillar junctions will enable real-time monitoring of health and safety risks to miners. The difference between the ratio of CO and O2 concentration at the outlet and inlet signal is used to detect fires when the difference is above a preset threshold. This results in activation of the temperature sensor nodes to identify the exact fire position.62
In addition to the major consequences caused by combustion and explosion of flammable and oxidizing gases, overexposure to certain gases in the mining environment could result in adverse effects on the health and safety of miners.66,74 Therefore, real-time and selective monitoring of certain gases in complex mining environments will meet a critical demand to ensure safe work conditions for mine workers. In the following subsections, we provide an overview of different nanomaterial-based sensing modules under research and development for detecting critical mining gases.
4. Nanosensors for critical gases in the coal mines
Traditional mine sensors monitor parameters such as temperature, smoke particles, and color of the fire to provide early warnings but with limited accuracy. Advances in gas sensor technologies have enabled the research and development of real-time, low-cost, and networkable gas sensors for mine and fire safety.75
Commercial chemical sensors deployed for gas monitoring in mining environments are usually based on bulk or thick-film materials.76 Such bulky devices require high power consumption and often contain limited diffusive pathways for gas molecules to interact with the sensor. Replacing bulk materials with nanomaterials thus allows device miniaturization with significant reduction in weight and power consumption. Nanosensors provide a larger surface-to-volume ratio of the sensing interface than traditional sensors leading to improved gas-detection sensitivity. Sensor miniaturization enables the fabrication of multilayered assemblies and interfaces or nanosensor arrays with tailored chemistry for enhanced gas-detection selectivity for a single gas as well as gas mixtures. Moreover, nanosensors offer faster response times owing to the improved diffusion of gas molecules and larger interfacial surface area.1,5
Popular mining gas sensors include sensors based on thermal conductivity60 and catalytic combustion,77 tunable diode laser absorption spectroscopy (TDLAS) sensors,2 and non-dispersive infrared (NDIR),78 and electrochemical sensors.55 Optical spectroscopic sensors such as TDLAS and NDIR sensors require large and expensive equipment and are challenging to integrate into portable or wearable optoelectronics. Thermal conductivity and catalytic combustion sensors are widely used for CH4 detection, but their performance is limited by the bulk nature of the sensing interfaces. Incorporating nanomaterials thus offers a solution to address unmet needs in gas monitoring in mining operations. Electrochemical sensors are typically used to monitor O2 and CO,55 but their real-world applications are limited by short lifetime and electrolyte leakage. Nanomaterials comprising solid electrolytes and molecularly structured ionic liquids have emerged as promising candidates for improving electrochemical sensing systems.79,80Table 1 provides an overview of the sensors commonly utilized for mine monitoring and their advantages and disadvantages. It also outlines the benefits and limitations associated with the integration of nanomaterials in each sensor.
Table 1 Technologies for monitoring critical gases in coal mines and their advantages and shortcomings. Advantages and shortcomings of nanomaterial incorporation are highlighted for each type of sensor
Sensor |
Application in coal mines |
Advantages |
Disadvantages |
Nanomaterial incorporation advantages/shortcomings |
Ref. |
This technology, yet to be implemented in coal mines, is included here based on its potential applicability.
In NDIR and TDLS, gas molecules interact with electromagnetic waves rather than nanomaterials.
|
Catalytic combustion |
CH4 sensing |
High sensitivity and low cost |
Poor selectivity, surface poisoning, and frequent calibration |
Formation of dispersed catalytically active sites and lower working temperature/challenges in mixing nanostructures with a supporting material (γ-Al2O3) |
77 and 81 |
Thermal conductivity |
CH4 and H2 sensing |
Fast response |
Low sensitivity and selectivity |
Improving the permeability of the sensing material (ceramic beads) and increasing adsorption sites/challenges in the introduction and dispersion of nanomaterials into the supporting material |
60 and 82–85 |
Resistive MOS-baseda |
CH4 and CO sensing |
Miniaturized configuration and low cost |
Poor selectivity, sensitivity to temperature and humidity, and surface poisoning |
Possibility of fabricating multilayered assemblies to enhance selectivity, sensitivity, and response time/lack of a reliable and scalable manufacturing technology for the nanointerface |
38, 82 and 86 |
NDIR |
CH4, CO, and CO2 sensing |
Room-temperature operation, high specificity, and fast response |
High cost, large size, challenges in integration of electronics and optics, and easily affected by humidity and temperature |
N/Ab |
49, 78, 87 and 88 |
TDLAS |
CH4, CO, and CO2 sensing |
Room-temperature operation, high specificity, fast response, real-time measurement, and maintenance free |
High cost, large size, and challenges in integration of electronics and optics |
N/A |
2, 49, 82, 89 and 90 |
Electrochemical |
CO and O2 sensing |
High selectivity and sensitivity |
Electrolyte leakage, temperature sensitivity, and poor durability |
Incorporation of nanostructured solid electrolytes to improve durability and increase electrochemically active surface area/challenges in manufacturing nanointerfaces with long-term stability |
79, 82, 91 and 92 |
As discussed above, existing sensing technologies for monitoring critical gases in mining environments fall short of the requirements for efficient, sensitive, and real-time sensing. Nanotechnology holds the potential to address the limitations of current systems and enable the development of next generation nanosensors specifically designed for complex mining environments and operations. In the following sections, an overview of the nanomaterial-incorporated sensors under development for the mining sector is provided. The gas and sensor interaction mechanisms are described wherever relevant throughout the review. Strategies for boosting the performance of nanosensors are also discussed.
4.1. Methane sensors
Resistive sensors.
Most methane sensors studied so far are based on MOS-type resistive sensors. Such methane sensors mainly exploit an n-type semiconductor sensing layer where the exposure to reducing methane molecules results in an increase in the concentration of charge carriers at the interface and a decrease in resistance.82 Among different n-type sensing elements, tin oxide (SnO2) is by far the most studied functional material for methane93–98 and several successful commercial methane sensors have been developed based on SnO2.99 Further improvements in the performance of SnO2-based methane sensors have been accomplished through making composites, forming heterojunctions, and structural doping.100,101
Generally, doping MOS structures, i.e., SnO2 or indium oxide (In2O3), with noble metals such as platinum (Pt) and palladium (Pd) improves gas sensing performance through the formation of a wider EDL by enhancing interfacial oxygen chemisorption and ionization.102 This phenomenon is widely referred to as the “spill-over effect” or “chemical sensitization”.103–105 In addition to chemical sensitization, the presence of noble metal dopants in the MOS structure may lead to the formation of a “Schottky barrier” leading to electronic transmissions and charge separation at the metal/MOS interface, which is called “electron sensitization” (Fig. 3A).106,107
|
| Fig. 3 (A) Scheme of the chemical sensitization effect of noble metals incorporated into the sensing interface to improve the sensitivity of MOS sensors.106 Reproduced with permission from ref. 106 Copyright 2022 Elsevier. (B) Methane sensing mechanism of Cr-doped SnO2 structures based on successive methane oxidation and a decrease in the width of the depletion layer.111 Adapted with permission from ref. 111 Copyright 2019 Elsevier. (C) Charge carrier transport across dispersed SnO2 sites and nonporous graphene with a high surface area, enabling sensitive methane detection.117 Reprinted with permission from ref. 117 Copyright 2019 Elsevier. (D) Application of 2D vanadium carbide MXene for resistive methane sensing through the interaction of physisorbed methane with the surface functional groups of MXenes.151 Reproduced with permission from ref. 151 Copyright 2019 American Chemical Society. (E) Methane sensing achieved by the catalytic function and redox cycling of Pt sites in the SWCNTs/Pt-POM composite.149 Reproduced with permission from ref. 149 Copyright 2020 Proceedings of the National Academy of Sciences. | |
Due to known catalytic activity of Pd in the oxidation of hydrocarbons, Pd is one of the most researched dopants for MOS-based sensors.108 Depending on the operating conditions, in some cases oxidation of doped Pd to palladium oxide (PdO) at high temperatures is observed. This results in direct combustion of methane and reformation of non-oxidized Pd sites.109 In one example, Pd- and antimony (Sb)-doped-SnO2 interfaces exhibited excellent methane sensing performance in terms of sensitivity, response time, and reproducibility.108 The improvement in sensing properties of SnO2 upon doping was attributed to the catalytic effect of Pd on the dissociation of oxygen molecules and formation of oxidizing species as well as compensation of Sb5+ substitution in the SnO2 lattice leading to a reduction in the baseline resistance of the MOS sensor.108 In another study, pure SnO2 thin films (control) and films doped with different elements such as nickel (Ni), osmium (Os), Pd, and Pt were employed for methane sensing.110 The performance of the SnO2 thin film sensor was optimized by leveraging the results obtained from employing different dopants. Among the utilized dopants, Os appeared to improve methane sensing performance and reduce the working temperature of the sensor. Os was substituted into the SnO2 lattice as Os3+ with an unpaired d electron to catalyze first-step fragmentation of methane into hydrogen and CH3 radicals.110 In a similar study, Bunpang et al. prepared chromium (Cr)-doped SnO2 nanoparticles through substitutional incorporation of Cr (in the form of Cr3+) into the MOS lattice.111 Cr-doped SnO2 showed remarkable sensitivity (sensing response, which is defined by the ratio of initial sensor resistance to its resistance after exposure to methane, = 1268.6) and selectivity (evaluated against H2, C2H2, NO2, NO, N2O, CO, NH3, SO2, C2H5OH, C3H6O, and H2O) with a response time of 3.9 s at 350 °C working temperature and 1% methane. The improved gas sensing performance was explained by the surface area increase using doped MOS particles and generation of holes upon Cr incorporation, which leads to a decrease in electron concentration, increasing the width of the depletion layer. The gas sensing mechanism, shown in Fig. 3B, consists of several steps: (1) successive oxidation of methane to CO and CO2 and formation of reactive oxygen species (ROS) at the MOS interface, (2) desorption of ROS, (3) interfacial release of electrons, (4) formation of a receded depletion layer, and (5) an increase in the electrical conductivity.111
Another popular approach for improving the performance of gas sensing layers is based on the formation of composites and MOS-based heterojunctions.112–115 In a study by Vuong et al., nickel oxide (Ni2O3)-decorated SnO2 composite films reduced the working temperature and enhanced methane sensing performance due to the synergistic effect of the composite material.116 In this case, a p–n heterojunction between Ni2O3 and SnO2 is formed. In addition, Ni2O3 depletes the electrons from an n-type MOS more than chemisorbed O2.
Other studies have employed carbonaceous nanomaterials for methane sensing.103 Kooti et al. employed a hybrid material consisting of SnO2 nanorods and nanoporous graphene.117 Their results show a substantial reduction in the operating temperature down to 150 °C and 600% increase in gas response compared to that of pure SnO2. This significant improvement was attributed to a higher surface-to-volume ratio and rapid charge carrier transport through SnO2 sites uniformly dispersed on conductive graphene (Fig. 3C).
Using similar strategies, other n-type MOS sensors based on In2O3,106,118–123 zinc oxide (ZnO),124–132 tungsten trioxide (WO3),133,134 iron borate (Fe3BO6),135 molybdenum disulfide (MoS2),136 and titanium oxide (TiO2)137,138 have been developed for methane sensing. In a study by Lu et al., Pd–In2O3 was utilized for methane sensing and its cross-sensitivity to several interfering gases was observed.139 To maintain the selectivity for methane, they constructed a multilayer sensor consisting of a catalytic film on top of the sensing element. Catalytic filters of Pt–TiO2, Pt–cerium oxide (CeO2) and Pt–zirconium oxide (ZrO2), printed on the Pd–In2O3 layer, were effective in removing the background interference from CO, NO2, and ethanol. The basic sensing mechanism of a noble metal-doped MOS did not change after incorporating the catalytic filters.
There are some reports on p-type semiconductors for methane detection. Holes are the main charge carrier in the p-type materials. The chemisorption of O2 at high temperature removes the electrons from the conduction band of the semiconductor, thus increasing the hole charge carrier concentration and broadening the HAL. This results in a decrease in the resistance of the sensor. Exposure to a reducing gas such as methane releases the electrons back to the conduction band leading to the recombination of electrons and holes and an increase in the resistance of the sensor. So far, p-type interfaces based on tricobalt tetraoxide (Co3O4),140 lead sulfide (PbS),141,142 vanadium dioxide (VO2),143 iron oxide (Fe2O3),144 Co3O4/dicobalt tetraoxide (Co2O4),145 and copper(I) oxide (Cu2O)146 have been exploited for resistive methane sensing.
Other emerging nanomaterials applied to methane detection include MXenes,147,148 metallic complexes,149 and metal organic frameworks (MOFs).150 Lee et al. demonstrated room-temperature methane sensing by using 2D vanadium carbide MXene (Fig. 3D) reaching a limit of detection (LOD) of ∼9 ppm.151 Oxygen-containing surface functional groups of the MXene presumably provide necessary affinity for methane adsorption. In a study on metallic complexes for methane sensing, a composite of single-walled carbon nanotubes (SWCNTs) and Pt polyoxometalate (Pt-POM) showed selectivity and ppm-level sensitivity for methane detection.149 Sensing was carried out at room temperature and the sensitivity for methane was attributed to the catalytic activity of the composite and redox cycling of Pt (Fig. 3E).
Catalytic combustion sensors.
For methane detection, a common sensor type employed in coal mines is the catalytic combustion type of methane sensors.152,153 The heat generated by methane combustion on a catalytic material is converted into an electrical signal in this type of sensor. A typical configuration consists of a catalyst embedded into an aluminum oxide (Al2O3) film mounted on a pellistor.154 Pt, Pd, Rh, and rare-earth perovskites are among the most commonly used catalysts in methane combustion sensors.59,77,155,156 In a study by Wang et al., different catalytic systems of Pt–Pd/Al2O3, Pt–Pd/n-Al2O3, and Pt–Pd/n-Ce-Al2O3 were tested for combustion-based methane sensing.81 Their results show that doping the nanostructures with Ce presented anti-sulfur ability, lowered the reaction temperature and enhanced the catalytic activity owing to the redox properties of Ce.81
Methane combustion sensors are cost-effective, simple, easy-to-fabricate, and selective. However, they suffer from catalyst poisoning, saturation upon exposure to high concentration of gases, inaccuracy in small enthalpy changes, and high power consumption.46 To reduce the power consumption and improve the sensitivity of such methane sensors several strategies have been put forth, including application of a pulsed voltage to the bridge circuit,157 miniaturization,158 and exploitation of dual catalysts on hot and cold terminals.155
Electrochemical sensors.
Electrochemical sensing of methane is mainly accomplished through its oxidation reaction and resultant current changes based on gas concentration. Different electrode materials, catalysts, and electrolytes are being explored to improve the performance of methane electrochemical sensors. The earliest reports on methane electrochemical sensing were based on methane oxidation on a Pt electrode in liquid electrolytes.159,160 Due to the limited diffusion of gas molecules in liquid electrolytes as well as electrolyte leakage and evaporation, other types of electrolytes including ionic liquids (ILs)80 and solid-state electrolytes161 were explored. In the case of IL electrolytes, negligible vapor pressure, thermal stability, and a wide potential window improve the performance and lifetime of the sensors. In a study by Wang et al., a pyrrolidinium-based IL electrolyte was used for simultaneous sensing of methane and oxygen. The sensing mechanism, shown in Fig. 4A, was based on the incomplete oxidation of methane to CO, followed by CO oxidation to CO2 by active oxygen species generated from the oxygen reduction reaction. The in situ produced CO2 was used as an internal standard enabling cross-validation and measurement error reduction.162
|
| Fig. 4 (A) Electrochemical methane sensing using IL-based electrolytes. CO2 generated by successive methane oxidation on the WE, and active oxygen species were used as an internal standard.162 Adapted with permission from ref. 162 Copyright 2014 Royal Society of Chemistry. (B) Scheme showing a multilayered electrochemical device based on solid-state electrolyte Nafion for methane sensing.161 Reprinted with permission from ref. 161 Copyright 2018 American Chemical Society. | |
As a leakage-free and thermally stable class of electrolytes, solid-state electrolytes appear to be a good alternative to conventional liquid electrolytes in methane electrochemical sensors.163,164Fig. 4B shows a solid-state methane sensor developed by Gross et al.161 In this configuration, Nafion was used as a solid-state electrolyte, which conducts the protons produced during the redox reaction of methane between the WE and the counter electrode.
Other types of methane sensors.
Although most methane sensors are of the resistive and combustion types, other nanomaterial-enabled sensing modules have been reported for methane sensing. In the category of optical sensors, Mishra et al. utilized graphene-CNT/poly (methyl methacrylate) for SPR-based fiber optic sensing of methane.165 The shift in the resonance wavelength upon exposure to the gas was correlated to the methane concentration in the range of 10–100 ppm. Other optical sensing methods based on midinfrared light emitting diodes,166 refractive index-modulated optical fiber systems,167 photoacoustic spectroscopy,168 and photoelectrochemical detection169 have been demonstrated for methane quantification. In addition to optical sensing, methane detectors based on QCM170 and SAW171 have been developed, but their complexity in device design and user training has so far limited their applications in the mining sector.
4.2. Carbon dioxide sensors
Resistive gas sensors.
Similar to methane sensing, most of the resistive CO2 sensors are based on MOS materials. ZnO is one of the most popular MOS materials for CO2 sensing. ZnO is an n-type semiconductor and CO2 is an oxidizing gas. The chemisorption of CO2 on the surface of ZnO results in EDL widening and increased resistance. Structural doping,172,173 UV illumination,174 and heterojunction formation175,176 in a ZnO-based MOS have been studied to improve its CO2 sensing performance. In a study by Joshi et al., a heterostructure of ZnO-calcium oxide (CaO) was shown to achieve sensitive (26–91%) and selective CO2 sensing at 150 °C in the range of 100–1000 ppm.177 The heterojunction was synthesized through chemical conversion of zinc hydroxide carbonate to ZnO by using calcium hydroxide, which enabled the formation of an n–n type nanointerface with extensive modulation of the potential barrier. The improved selectivity and sensitivity were attributed to higher CO2 adsorption on CaO due to the basicity of the Ca ion and improved charge-transfer reversibility. In another similar study, an Ag-doped ZnO–CuO heterojunction was utilized for room-temperature, sensitive CO2 detection within the range of 150–1000 ppm.178 The sensing mechanism, shown in Fig. 5A, was explained by the formation of a p–n heterojunction at the ZnO–CuO interface, which results in the movement of the electrons and holes (due to the difference in work functions of ZnO and CuO) and an increase in the number of free electrons near the surface. This is followed by chemisorption and ionization of oxygen and water molecules as well as a reduction in the HAL and an increase in the resistance of the sensor upon exposure to CO2. The dopant (Ag) improved the sensing performance due to the formation of a Schottky barrier, increased carrier mobility, and chemical sensitization.
|
| Fig. 5 (A) Room-temperature CO2 sensing by a Ag-doped ZnO–CuO (p–n) heterojunction where the charge carrier movement provides more electrons for oxygen chemisorption. This is followed by a reduction in the HAL upon exposure to CO2.178 Reprinted with permission from ref. 178 Copyright 2023 Elsevier. (B) Illustration showing the CO2 sensing mechanism using Ru–WS2/Au electrodes.187 Adapted with permission from ref. 187 Copyright 2020 Institute of Physics. (C) EIS-based CO2 sensing via disruption of the IL assembly at the electrode interface due to CO2 inclusion.192 Reproduced with permission from ref. 192 Copyright 2023 American Chemical Society. (D) A FET sensor developed for CO2 sensing based on an electrolyte-gated mode using an IL and In2O3 as the electrolyte and channel forming layer, respectively.203 Reprinted with permission from ref. 203 Copyright 2020 Elsevier. | |
Other sensing materials including SnO2,179 TiO2,180 CeO2,181 CuO,182,183 In2O3,184 rare-earth oxycarbonates and oxides,185 bismuth oxide (Bi2O3),186 and tungsten disulfide (WS2)187 have been explored for CO2 sensing. In a study by Zito et al., yolk–shell CeO2 nanoparticles with high surface area and enhanced gas diffusion were explored for CO2 sensing.181 Their sensor showed fast response, stability, and high sensitivity to CO2 at 100 °C owing to the high adsorption capacity of the yolk–shell nanoparticles. In another study, quantum dots (QDs) of Ru-decorated WS2 were applied for room-temperature CO2 sensing within the concentration range of 500–5000 ppm.187 In the case of WS2, which is a p-type semiconductor, the sensing mechanism (Fig. 5B) was explained by CO2 chemisorption and breakage into CO and O2 leading to electron donation to the sensing interface, a decrease in the concentration of holes, and an increase in the resistance. Ru was assumed to have a catalytic role enabling fast CO2 reduction. Moreover, the presence of Ru led to a reduction in the ohmic loss and rectification at the interface of Ru–WS2/Au electrodes (an electrode on the sensor substrate).
In addition to conventional oxides based on single metallic elements, high-entropy metal oxide nanoparticles have been used for room-temperature and wide-range CO2 sensing (250–10,000 ppm). Gd0.2La0.2Y0.2Hf0.2Zr0.2O2 (Y-HEC) was explored for CO2 sensing using three different electrodes including Ag, Au, and indium tin oxide (ITO).188 The results show that Y-HEC made a perfect ohmic contact with the Ag electrode where the total resistance of the sensor was only controlled by the channel resistance of the sensing material without any contribution from the contact resistance at the metal–semiconductor interface. On the other side, a Schottky contact was formed at the Y-HEC/ITO and Y-HEC/Au interface with a lower Schottky barrier height (SBH) in the case of ITO. The highest response was obtained at the ITO interface, which revealed the vital role of the Schottky contact in gas sensor performance. Exposure to CO2 and release of electrons at the interface result in a downward shift in the level of the conduction band, which is followed by Schottky barrier modulation (SBM) and a reduction in the SBH. In gas sensors based on SBM, the presence of an optimized SBH leads to improved sensor performance. The lower sensitivity in Y-HEC/Au, compared to ITO one, was attributed to a large SBH, which prevented effective charge transfer.188
Electrochemical sensors.
Electrochemical sensors based on potentiometric, amperometric, and impedance measurements have been employed for CO2 sensing. Among them, potentiometric sensors suffer from limited sensitivity as they respond to changes in EMF (electromotive force) against concentration on a logarithmic scale.189 Amperometric sensors are the most common module for electrochemical sensing of CO2 owing to their sensitivity, selectivity, ease of operation, and facile data interpretation.
Different types of solid and liquid electrolytes have been exploited for CO2 electrochemical sensing. IL-based CO2 sensors have been developed to take advantage of the tunable composition of ILs to enhance CO2 solubility and detection selectivity.190 In a study by Fapyane et al., a mixture of IL 1-ethyl-3-methylimidazolium dicyanamide (EMIMDCA) and dimethylformamide (DMF) was used for the amperometric sensing of CO2via its reduction on the Ag WE.191 The addition of DMF reduced the response time and overpotential of CO2 reduction due to a decrease in stability of the CO2–EMIMDCA complex. The IL mixture enabled quantitative measurements of CO2 in the range of 0–4.62 kPa with a LOD of 0.5 kPa. In another study, Sridhar et al. developed an IL-based CO2 sensor operated based on the impedance readout.192 They investigated their gas sensing setup at different temperatures using a Pt black electrode. A decrease in the real component of the resistance was observed upon CO2 exposure, which was attributed to CO2 inclusion and disruption of the cation–anion interaction in molecularly structured IL film formed at the interface (Fig. 5C). At lower operating temperatures, increased viscosity of ILs and formation of a dense film made of ionic charges appear to increase the sensitivity of the sensor.
In addition to ILs, solid electrolytes are another group of popular electrolytic media widely employed for CO2 electrochemical sensing.193 Yttria-stabilized zirconia (YSZ) is often utilized as such an electrolyte, which has shown promise for amperometric measurements of CO2 up to the concentration level of 10% within the temperature range of 600–750 °C.194 In a study on the development of solid electrolytes for CO2 sensing, Ma et al. introduced Y-doped La9.66Si5.3B0.7O26.14 (Y-LSBO) as the electrolyte, which was coated with a working electrode film made of a Li2CeO3–Au–Li2CO3 composite.195 In this layered assembly, Li2CeO3 functions as an ionic bridge between the solid electrolyte with O2− conductivity and Li2CO3 as the Li+ conductor. The sensor was operated based on the EMF readout and showed a Nernstian behavior for CO2 measurements within the range of 400–4000 ppm at 400 °C.
Apart from the reports replying only on the electrochemical input, a nanocomposite of ZnO/MoS2/reduced graphene oxide (rGO) was reported to allow sensitive photoelectrochemical sensing of CO2. In this case, a heterojunction was formed at the ZnO–MoS2 interface, and rGO functioned as a conducive bridge to facilitate the electron transfer. This assembly enabled CO2 detection in the range of 10–7820 ppm with a LOD of 10 ppm and response time of 10 s.196
Optical sensors.
A variety of nanomaterial-incorporated optical CO2 sensors based on SPR,197 colorimetry,198 and infrared spectroscopy199 have been developed. In SPR-based CO2 sensors, CNTs are the most utilized plasmonic materials owing to their high affinity to CO2. However, poor selectivity and the existence of interfering excitation regions limit the application of CNT sensors in challenging mining environments.200
Colorimetric CO2 sensing is usually carried out by using semiconductor QD nanocrystals where a change in the emission intensity and/or blue or red shift can occur upon CO2 adsorption.198,200 In such sensors, although colorimetric measurements allow CO2 sensing in a cost-effective and facile manner, the semi-quantitative readout and poor long-term stability of QDs make them a less popular choice for the mining industry.
In CO2 sensors based on IR spectroscopy, nanomaterials are incorporated either into the light emitting source or the photodetector part.200 Such sensors normally have a chamber configuration, where certain IR wavelengths are absorbed by CO2 molecules. Having the CO2 IR spectrum as the readout, these sensors offer high accuracy, fast response, and durability. Their drawbacks include high cost, device complexity, and difficulty to scale up.
Other types of sensors.
Based on our literature review, CO2 sensing is dominated by electrochemical and MOS-type resistive sensors. Other less common CO2 nanosensors rely on SAW,201 QCM,202 and FET.203 An advantageous version of such sensors with potential applications in mining, was introduced by Ersoez et al.203 Their sensor was based on a new concept of an electrolyte-gated transistor (EGT). As shown in Fig. 5D, they used an In2O3 film as a channel-forming layer in a FET and [EMIM][BF4] IL as an electrolyte separating the gate from the channel. Exposure to CO2 caused O2 depletion at the MOS interface resulting in an increased conductivity of the sensor. In this case, the IL provides a medium for dissolution of the gaseous reactants and modulates the charge carrier distribution in a MOS via the formation of an electrical double layer. This configuration enabled CO2 quantification in the range of 400–4000 ppm with a sensitivity of 0.1%/ppm and a recovery time of 20 s.
4.3. Carbon monoxide sensors
Resistive sensors.
Functional nanomaterials utilized in CO sensors include n-type204 and p-type205 MOSs as well as polymers.206 Considering CO as a reducing gas, CO interactions with an n-type MOS remove the ionized oxygen species, inject electrons back to the MOS, and decrease the overall electrical resistance of the sensor. A variety of nanostructures based on n-type MOSs of SnO, ZnO, In2O3, TiO2, WO3, and CeO2 have been employed for CO sensing.207 In a recent study, the CO sensing mechanism of a composite of SnO2/SiO2–PdOx was studied in dry and humid air using DRIFT (diffuse reflectance infrared Fourier transform spectroscopy) analysis.204 The spectra revealed the contribution of PdOx to CO oxidation and the role of SiO2 in preservation of the bridge oxygen atoms on SnO2 as well as the prevention of carbonate poisoning by decreasing the basicity of the sensing interface.204 In addition to n-type semiconductors, p-type MOSs have also been employed for CO sensing due to their higher catalytic activity and less temperature dependency of their conduction at elevated temperatures.205,207 CuO205 and Co3O4208 are among popular p-type MOSs for CO sensing. Regardless of the MOS type, doping,209 heterojunction assembly,210 and nanocomposite formation211 have been used to enhance CO sensing performance of MOS-based sensors. In a recent study by Yuan et al. porous nanoplates of n-ZnO/p-Co3O4 (Fig. 6A), derived from the zeolitic imidazolate framework, were used for selective and sensitive CO sensing.212 This nanomaterial exhibited a large surface area and high level of oxygen vacancy in the crystal structure, thus allowing strong chemisorption of CO molecules and high sensitivity with a response value of 35.4. According to the results, inclusion of Zn-based components appeared to be essential for anti-interference, i.e., selectivity against interferents such as CH4, H2S, nitric oxide (NO), ammonia (NH3), and H2.
|
| Fig. 6 (A) Zeolitic imidazolate framework-derived n-ZnO/p-Co3O4 nanomaterials for CO sensing. The sensing nanomaterial presents many oxygen vacancies and enables strong chemisorption.212 Reprinted with permission from ref. 212 Copyright 2023 Elsevier. (B) Schematic of a potentiometric O2 sensor based on YSZ solid electrolyte.79 Adapted with permission from ref. 79 Copyright 2003 Springer. (C) A typical configuration of a mixed mode potentiometric–amperometric O2 sensor.232 Reprinted with permission from ref. 232 Copyright 2022, The Authors, under Creative Commons Attribution (CC-BY) license, published by Multidisciplinary Digital Publishing Institute. | |
Electrochemical sensors.
Electrochemistry is one of the best developed detection methods for CO sensing. Among different electrochemical modules, amperometry is the most utilized technique, where the current produced upon oxidation of CO to CO2 is tracked against time.92 In addition to amperometric sensors, there are a few demonstrations of potentiometric213,214 and EIS-based215 systems for CO sensing.
CO electrochemical sensor development mainly explores WE materials and electrolytic media. For the WE materials, metallic216 and metal oxide-based217 nanostructures as well as CNTs218 have been shown to provide effective sensing interfaces for CO electrochemical sensing. A Pt microdisk electrode modified with multi-walled CNTs (MWCNTs) was found to have a catalytic effect on CO oxidation with a reduced overpotential. The incorporation of MWCNTs allowed CO sensing within the range of 0.72–52 μg ml−1 with a LOD of 0.60 μg ml−1.219 Similarly, a nanocomposite of Pt–Ni alloy deposited on polyaniline-MWCNTs exhibited a bifunctional catalytic activity toward CO oxidation while neighboring Ni removed the reaction intermediates. A linear sensing response was obtained within the range of 1.0–50 μM with a LOD of 0.5 μM.220 The last two mentioned studies both used a liquid electrolyte of perchloric acid for sensing. To fabricate robust and durable sensors specifically suited for mining environments, electrolytic media other than aquatic solutions are required. To this end, electrochemical CO sensors based on solid electrolytes and ILs have been reported.221,222 Both inorganic and polymeric solid electrolytes223 have shown promises for CO sensing. In one of the earliest reports, a semipermeable and proton-conductive Nafion membrane was used to cover the surface of all three electrodes (sputtered Pt films served as the working and counter electrodes and a sputtered Au film was used as the reference electrode) required for electrochemical sensing.223 The sensor showed excellent durability of >2 year lifetime, a working range of 0–2000 ppm, and a response time of 30 s for CO sensing. The remarkable sensing performance was attributed to CO permeability of Nafion and the higher oxidation rate of CO. In a study of inorganic solid electrolyte-based CO sensors, Phawachalotorn et al. used a Fe-doped La0.8Sr0.2GaO3 solid electrolyte in combination with electrocatalysts Au 10 wt%–In1.9Sn0.1O3 (ITO955) and RuO2–La0.6Sr0.4CoO3 (LSC64) for amperometric CO sensing.224 This type of sensor operated within a temperature range of 300–500 °C and showed a sensitive (8.83 mA per decade) and selective (over CH4, CO2, and H2) response to CO.
Other types of sensors.
In addition to the traditional CO sensors developed for mining applications such as the chemiresistive and electrochemical types, other less developed CO sensors include QCM,225 FET,226 SAW,227 and optical (e.g., SPR,228 reflectometry,229 and fluorescence,230) sensors. In particular, FET-based CO sensors are promising for field applications. Singh et al. demonstrated room-temperature CO sensing by using Zn-doped In2O3 nanowires (NWs) in an FET configuration.231 Zn doping enhanced the sensor response and enabled CO sensing within the range of 1–5 ppm with a selective response over NO and nitrogen dioxide (NO2).
4.4. Oxygen sensors
Electrochemical sensors.
Electrochemical O2 sensors based on solid electrolytes are the most studied commercial sensors for O2 measurements in the gas phase. Traditionally, O2 sensing is carried out at high temperature in a planar configuration using YSZ as a solid electrolyte with oxygen conduction. As can be seen in Fig. 6B, the sensor is constructed in a multilayered configuration with two Pt electrodes exposed to the test gas stream and the reference gas. The electromotive force, resulting from the oxygen pressure disparity between the two Pt electrodes, serves as the measured signal readout. Upon exposure to the target gas stream, the molecular oxygen adsorbs on the Pt sites, which is followed by O2 dissociation to atomic oxygen and its ionization/reduction at the electrode–electrolyte-gas boundary, referred to as the triple phase boundary (TPB). As YSZ has a high level of oxygen conduction, the chemical potential of reduced oxygen species is not changed in the solid electrolyte media. Thus, the difference in chemical potential of O2 exists at the test stream, and the reference stream generates an EMF for potentiometric O2 sensing.79,91 Advances in such O2 sensors involve the replacement of the reference Pt/gas interface, with metal/metal oxide interfaces to simplify the sensor configuration and improve its applicability. Several metal/metal oxide interfaces based on Sn, In, Ni, and Ru have been explored as the reference, and they can maintain a desirable oxygen partial pressure at a given temperature (<500 °C).232
Apart from commercial potentiometric oxygen sensors, amperometric modules have been employed to remove the logarithmic dependency of concentration to the readout and allow O2 sensing within a wider concentration window. The amperometric sensors record the current generated from oxygen reduction and have been used for sensing of O2 dissolved in liquid electrolytes233 and O2 in the gas phase at the interface of a solid electrolyte and an electrode.232 In the case of solid electrolytes, in addition to the conventional YSZ,79 samarium (Sm)-doped CeO2 has high oxygen ion conductivity enabling amperometric O2 sensing within the range of 100–500 ppm at 550 °C.234
The limiting current in these sensors depends on the applied direct current (DC) potential utilized to pump molecular oxygen to the working electrode surface. Depending on the target test stream, different potentials may be required to achieve a steady-state current. To compensate for this dependency and improve the reliability of O2 amperometric sensors, a combined amperometric–potentiometric sensing technique has been introduced. Fig. 6C shows a typical design consisting of two electrochemical chambers of an amperometric and a potentiometric cell, respectively. In the amperometric chamber, O2 is pumped and measured based on the limiting current, and the potentiometric chamber records the EMF value and provides additional information on sensor performance and the analyte concentration.79,232
Resistive sensors.
O2 resistive sensors usually operate based on O2 chemisorption on MOS materials. Among a variety of MOS-based O2 sensors, Ti-, Ga-, and Ce-based semiconductors are the most common. Semiconductors of TiO2, SrTiO3, Ga2O3, CeO2, and Nb2O5 with n-type characteristics have shown sensitivity toward O2 molecules.79,235 The sensitivity is obtained through a sequence of events including the formation of oxygen adsorbents, occupation of oxygen vacancies in the n-type MOS, a reduction in the concentration of electrons as charge carriers, and an increase in the resistance of the sensor. So far, several O2 resistive sensors based on TiO2 thick films have made it into the market.235 New advances have focused on the exploitation of nanostructures and thin films of TiO2 (either in a pristine or composite form) to further enhance O2 sensing properties.236 Thin films of TiO2 with a particle size of ∼34 nm were found to have a high response to O2 at low operating temperatures within 150–300 °C.237 Strontium titanate (SrTiO3) is another popular Ti-based semiconductor with a perovskite structure widely employed for high temperature O2 sensing. At a low oxygen partial pressure, oxygen vacancies in SrTiO3 result in an n-type behavior while at a high oxygen partial pressure (>1 Pa), Sr vacancies dominate the semiconductor structure giving rise to a p-type behavior of the sensing material.79 In this case, doping the structure with donor or acceptor elements (i.e., La or Fe, respectively) brings about a shift in the p–n transition and a monotonic signal change versus the O2 concentration in the donor-doped structures.238
Among the other n-type MOS interfaces reported, CeO2 is a well-researched material for O2 sensing.239 The Ce atoms inside the CeO2 crystalline lattice possess variable oxidation states of Ce3+/Ce4+, which leads to oxygen storage capability and fast oxygen vacancy diffusion in CeO2. The latter feature was attributed to the significant reduction in the response time of the O2 sensor.79,235 Films of CeO2 have been reported to have response times within 5–10 ms.197 Moreover, the addition of Zr to Ce forms a mixed oxide phase and further increases the charge carrier mobility resulting in a response time within the range of 1–20 ms.240
Several p-type semiconductor interfaces exhibiting temperature-independent resistivity have also been explored for O2 sensing. Examples of such temperature-independent interfaces include lanthanum cuprate (La2CuO4+δ), SrTi1−xFexO3 (STF), and BaFe1−yTayO3.235 The temperature independency of resistance in STF was explained by the compensation of temperature-induced formation of charge carriers due to strong temperature-dependent mobility of holes and a decrease in the bandgap upon the incorporation of Fe electronic bands into SrTiO3.241
Other types of sensors.
Other types of O2 sensors utilizing nanomaterials, less suitable for harsh mining environments, include FET242 and photoluminescence sensors.243 Fan et al. incorporated single-crystal ZnO NWs into the FET configuration for O2 sensing,244 and reported thinner NWs to exhibit higher sensitivity enabling O2 measurements in the range up to 50 ppm.
An amine-functionalized silver-chalcogenolate-cluster-based MOF was employed as a dual fluorescence-phosphorescence probe for O2 sensing. Ratiometric sensing was conceived as O2-induced phosphorescence quenching relative to an O2-independent fluorescence signal as the readout. It was shown that a second functionalization with methyl moieties can interfere with the quenching process providing a wider sensing concentration range of 0.5–20 ppm. The sensor displayed a response time of 0.3 s.245
5. Direct electrodeposition of charge-transfer complex-based nanosensors
Charge-transfer complexes (CTCs) refer to a group of organic and organometallic conductors and semiconductors with unique electrocrystallization properties. CTC molecular assemblies are made through a charge transfer process between electron acceptor and electron donor counterparts giving rise to conductive to semiconductive characteristics.246–248Fig. 7A shows the molecular packing structure in tetrathiafulvalene-7,7,8,8-tetracyanoquinodimethane (TTF-TCNQ), one of the most studied CTCs.249 In such a molecular assembly, electrons are delocalized along the stacks of electron acceptor/donor molecules, and conductive crystals are grown along the c-axis leading to a 1D columnar structure.250 These 1D semiconducting crystals offer numerous synthetic chemistry variations for scalable manufacturing of gas nanosensors. We have previously shown the possibility of controlled electrocrystallization of 1D CTCs through seed mediation251 (Fig. 7B) and substrate patterning252 (Fig. 7C). These strategies offer a versatile approach for precise electrodeposition of CTC nanosensors directly on sensor circuitry. Direct electrocrystallization of such nanowire sensors will enable low-cost production of high-quality crystalline nanomaterials as an effective additive manufacturing strategy to overcome a major challenge in nanosensor commercialization.253
|
| Fig. 7 (A) Schematic illustration of molecular packing in TTF-TCNQ CTC.254 Adapted with permission from ref. 254 Copyright 2009 Institute of Physics. (B) Seed-mediated controlled growth of potassium tetracyanoplatinate sesquihydrate nanowires on gold nanoparticles.251 Reprinted with permission from ref. 251 Copyright 2017 Taylor & Francis. (C) Substrate-directed electrocrystallization of tetrathiafulvalene bromide (TTFBr) nanowires on patterned gold electrodes.252 Reprinted with permission from ref. 252 Copyright 2023 John Wiley & Sons, Inc. | |
CTC electrocrystallization has shown promises to create gas sensitive interfaces owing to CTC's semiconducting characteristics and tunable chemistry. Various compositions of CTCs can be exploited using electrochemistry (Table 2). Variations in molecular stacking, counterions, or stoichiometry of CTCs lead to different physical and chemical properties, which can be adjusted to achieve selective interactions with target gas molecules.255 There are several literature reports on CTCs being used for detecting both reducing256 and oxidizing257 gases. Our group has demonstrated the sensing performance of tetrathiafulvalene bromide (TTFBr0.76) nanowires electrodeposited directly on patterned electrodes for ammonia measurements.256 According to our observations, depending on the CTC stoichiometry, different sensor readouts of ammonia were accomplished. In insulating TTBr1.0, exposure to reducing ammonia increases the concentration of charge carriers and reduces the resistance. In the case of conductive TTFBr0.76, electron injection neutralizes TTF+ and obscures intermolecular donor–acceptor interactions resulting in an increased resistance.256 In another research study on gas sensing capability of CTCs, Wang et al. applied the TTF-TCNQ complex for measuring and differentiating alkyl amines and aromatic amines.258 In both cases, after exposure to the amines, the electrical current readout over TTF-TCNQ decreased due to donor–acceptor interactions between amines and TCNQ, which competes with that of TTF-TCNQ. Given the higher basicity of alkylamines than that of aromatic amines, they form a stronger bond with TCNQ, and an irreversible signal was observed in this case, while in the case of aromatic amines, the sensor signal was recovered after a few seconds. Hence, the recovery behaviour of the sensor was used as a criterion for distinguishing between alkyl amines and aromatic ones.258 Another research study has demonstrated the sensitivity of the TTF-TCNQ complex to oxidizing gas species, such as CO2, O2, and NO2, through alteration of the charge transfer in the complex resulting in a reduction in conduction.259
Table 2 Donor and acceptor counterparts commonly used for the synthesis of CTCs
Common donor components |
Common acceptor components |
Tetrathiafulvalene (TTF) |
7,7,8,8-Tetracyanoquinodimethane (TCNQ) |
|
|
Bis(ethylenedithio)tetrathiafulvalene (ET) |
Cl−, Br−, I−, PF6− |
|
|
Tetramethyltetraselenafulvalene (TMTSF) |
|
|
|
Ag, Cu, and Co |
|
Taken all together, CTCs present a potential application for gas monitoring in mines. Compared to MOS-based systems, the sensing interfaces based on CTCs offer a versatile manufacturing technology, possess tailorable chemistry, and operate at room temperature. CTC nanosensors could respond to reducing and oxidizing gas molecules of CH4 and CO, respectively, as demonstrated in a limited number of studies on similar molecules so far.258,259 The possibility of fabricating aligned nanowires through a simple substrate-directed electrochemical route offers a means for constructing nanosensor arrays capable of multiplexed measurements in a single wearable or portable and networkable device.
6. Conclusions and future remarks
The present review provides an overview of the various sensing methodologies and nanomaterials employed for the detection of critical gases of interest in the mining industry. The sensing mechanisms and the interactions between the target gas molecules and the sensing nanomaterial are discussed for each sensing module and gas type. Based on our review of literature, it is evident that the emergence and extensive application of nanomaterials have advanced the gas sensor field rapidly and significantly. So far, a large variety of nanomaterials with certain characteristics, depending on the sensing method, have been incorporated into gas sensors for different gases. However, despite the broad development of a diverse array of nanomaterials, new understanding of the interactions between the adsorbed gas and the sensing interface has been lacking in the literature. In this regard, most literature reports rely on generally accepted mechanisms and theories for describing their sensing systems. Mechanistic investigations through actual experiments to provide deeper understanding of the sensing pathways and the role of each component in a typical composite material have been lacking. In addition to this, the majority of gas sensors developed to date (with the exception of certain optical and electrochemical systems) exhibit cross-sensitivity to both the target gas and background gases. Selectivity in gas sensors remains to be improved. To complement the development of nanomaterials with inherent gas selectivity, it is essential to incorporate surface functionalization, external filtering, and various data optimization methods to achieve the ultimate selectivity, enabling applications in highly variable mining environments.
The integration of nanostructures into gas sensing interfaces holds great promise for fabricating miniaturized, efficient, and accurate portable and wearable devices. Nanoscale structures provide a larger responsive interface over a given sensor area, leading to faster response times and higher sensitivity. The utilization of these portable devices enables early warnings over a wide area, making them easily networkable and applicable in the mining sector.
While the incorporation of nanomaterials into gas sensing platforms has greatly improved their applicability and performance, there still remain challenges in terms of developing facile, cost-effective, reproducible, and scalable fabrication techniques for integrating nanostructures into sensing interfaces. The direct electrocrystallization of nanostructures on patterned substrates, as discussed in the preceding section, offers a promising approach to overcome challenges in the integration of nanomaterials into sensing interfaces. Efforts aimed at upscaling laboratory nanosensor production, guided by new science and engineering principles, are crucial to propel scientific discoveries towards commercialization and widespread industry adoption.
Conflicts of interest
There are no conflicts to declare.
Acknowledgements
The authors are grateful for the support of the Australian Research Council (ARC grant number IH210100048).
References
- K. Xu, C. Fu, Z. Gao, F. Wei, Y. Ying, C. Xu and G. Fu, Instrum. Sci. Technol., 2018, 46, 115–145 CrossRef CAS .
- W. Gong, J. Hu, Z. Wang, Y. Wei, Y. Li, T. Zhang, Q. Zhang, T. Liu, Y. Ning and W. Zhang, Front. Phys., 2022, 10, 1162 Search PubMed .
- S. Sadeghi, N. Soltanmohammadlou and F. Nasirzadeh, J. Safety Res., 2022, 83, 8–25 CrossRef PubMed .
-
L. Granwal, Total Income of the Coal Mining Industry in Australia from Financial Year 2012 to 2021, 2023, https://www.statista.com/statistics/697085/australia-total-income-coal-mining-industry/ Search PubMed .
- R. Malik, V. K. Tomer, Y. K. Mishra and L. Lin, Appl. Phys. Rev., 2020, 7, 21301 CAS .
- J. Howard, V. Murashov, E. Cauda and J. Snawder, Am. J. Ind. Med., 2022, 65, 3–11 CrossRef PubMed .
- S. M. Majhi, A. Ali, P. Rai, Y. E. Greish, A. Alzamly, S. G. Surya, N. Qamhieh and S. T. Mahmoud, Nanoscale Adv., 2022, 4, 697–732 RSC .
- N. M. White and J. D. Turner, Meas. Sci. Technol., 1997, 8, 1 CrossRef CAS .
- E. Llobet, Sens. Actuators, B, 2013, 179, 32–45 CrossRef CAS .
- M. Kiani, M. U. Rehman, X. Tian and B. Yakobson, Adv. Mater. Technol., 2022, 7, 2101252 CrossRef CAS .
- A. Ashok, T. Nguyen, M. Barton, M. Leitch, M. K. Masud, H. Park, T. Truong, Y. V. Kaneti, H. T. Ta and X. Li, Small, 2023, 19, 2204946 CrossRef CAS PubMed .
- A. Azhar, Y. Li, Z. Cai, M. B. Zakaria, M. K. Masud, M. S. A. Hossain, J. Kim, W. Zhang, J. Na and Y. Yamauchi, Bull. Chem. Soc. Jpn., 2019, 92, 875–904 CrossRef CAS .
- J. Wang, Y. Ren, H. Liu, Z. Li, X. Liu, Y. Deng and X. Fang, Adv. Mater., 2022, 34, 2104958 CrossRef CAS PubMed .
- H. Yang, S. Cai, D. Wu and X. Fang, Adv. Electron. Mater., 2020, 6, 2000659 CrossRef CAS .
- X. Fang, L. Hu, C. Ye and L. Zhang, Pure Appl. Chem., 2010, 82, 2185–2198 CAS .
- H. Liu, C. Zuo, Z. Li, X. Liu and X. Fang, Adv. Electron. Mater., 2021, 7, 2100706 CrossRef CAS .
- H.-P. Phan, Y. Zhong, T.-K. Nguyen, Y. Park, T. Dinh, E. Song, R. K. Vadivelu, M. K. Masud, J. Li and M. J. A. Shiddiky, ACS Nano, 2019, 13, 11572–11581 CrossRef CAS PubMed .
- H.-P. Phan, M. K. Masud, R. K. Vadivelu, T. Dinh, T.-K. Nguyen, K. Ngo, D. V. Dao, M. J. A. Shiddiky, M. S. A. Hossain and Y. Yamauchi, Chem. Commun., 2019, 55, 7978–7981 RSC .
- M. K. Masud, M. N. Islam, M. H. Haque, S. Tanaka, V. Gopalan, G. Alici, N.-T. Nguyen, A. K. Lam, M. S. A. Hossain and Y. Yamauchi, Chem. Commun., 2017, 53, 8231–8234 RSC .
- M. K. Masud, J. Na, T.-E. Lin, V. Malgras, A. Preet, A. A. I. Sina, K. Wood, M. Billah, J. Kim and J. You, Biosens. Bioelectron., 2020, 168, 112429 CrossRef CAS PubMed .
- M. A. Wahab, J. Na, M. K. Masud, M. S. A. Hossain, A. A. Alothman and A. Abdala, J. Hazard. Mater., 2021, 408, 124843 CrossRef CAS PubMed .
- S. Dhall, B. R. Mehta, A. K. Tyagi and K. Sood, Sens., 2021, 2, 100116 Search PubMed .
- I. Raya, H. H. Kzar, Z. H. Mahmoud, A. Al Ayub Ahmed, A. Z. Ibatova and E. Kianfar, Carbon Lett., 2021, 1–26 Search PubMed .
- S. Mehdi Aghaei, A. Aasi and B. Panchapakesan, ACS Omega, 2021, 6, 2450–2461 CrossRef CAS PubMed .
- T. Zhou and T. Zhang, Small Methods, 2021, 5, 2100515 CrossRef CAS PubMed .
- M. Wusiman and F. Taghipour, Crit. Rev. Solid State Mater. Sci., 2022, 47, 416–435 CrossRef CAS .
-
G. Mao, US Pat., US10890556B2,Ref. 27: Please provide the patent type. 2021 Search PubMed .
- V. Balasubramani, S. Chandraleka, T. S. Rao, R. Sasikumar, M. R. Kuppusamy and T. M. Sridhar, J. Electrochem. Soc., 2020, 167, 37572 CrossRef CAS .
- A. Mirzaei, J.-H. Kim, H. W. Kim and S. S. Kim, J. Mater. Chem. C, 2018, 6, 4342–4370 RSC .
- A. Calvi, A. Ferrari, L. Sbuelz, A. Goldoni and S. Modesti, Sensors, 2016, 16, 731 CrossRef .
- N. Barsan, D. Koziej and U. Weimar, Sens. Actuators, B, 2007, 121, 18–35 CrossRef CAS .
- G. Neri, Chemosensors, 2015, 3, 1–20 CrossRef CAS .
- A. Mirzaei, J.-H. Lee, S. M. Majhi, M. Weber, M. Bechelany, H. W. Kim and S. S. Kim, J. Appl. Phys., 2019, 126, 241102 CrossRef .
-
Y. Deng and Y. Deng, Sensing Mechanism and Evaluation Criteria of Semiconducting Metal Oxides Gas Sensors, Springer, 2019 Search PubMed .
- Z. Wang, L. Zhu, S. Sun, J. Wang and W. Yan, Chemosensors, 2021, 9, 198 CrossRef CAS .
- D. R. Miller, S. A. Akbar and P. A. Morris, Sens. Actuators, B, 2014, 204, 250–272 CrossRef CAS .
- T. Lin, X. Lv, S. Li and Q. Wang, Sensors, 2017, 17, 2779 CrossRef PubMed .
- H. Nazemi, A. Joseph, J. Park and A. Emadi, Sensors, 2019, 19, 1285 CrossRef CAS PubMed .
- P. Zhang, Y. Xiao, J. Zhang, B. Liu, X. Ma and Y. Wang, Anal. Chim. Acta, 2021, 1172, 338575 CrossRef CAS .
- A. Paghi, S. Mariani and G. Barillaro, Small, 2023, 19, 2206100 CrossRef CAS .
- P. Feng, F. Shao, Y. Shi and Q. Wan, Sensors, 2014, 14, 17406–17429 CrossRef .
- C. Zhang, P. Chen and W. Hu, Chem. Soc. Rev., 2015, 44, 2087–2107 RSC .
- A. Lv, Y. Pan and L. Chi, Sensors, 2017, 17, 213 CrossRef PubMed .
- B. Zhan, C. Li, J. Yang, G. Jenkins, W. Huang and X. Dong, Small, 2014, 10, 4042–4065 CrossRef CAS PubMed .
- X. Yao, Y. Zhang, W. Jin, Y. Hu and Y. Cui, Sensors, 2021, 21, 995 CrossRef CAS PubMed .
- T. Yoshizumi and Y. Miyahara, Differ. Types Field-Effect Transistors-Theory Appl., 2017, 149–163 CAS .
- L. Luo and Z. Liu, View, 2022, 3, 20200115 CrossRef .
- J. Wu, G. Yue, W. Chen, Z. Xing, J. Wang, W. R. Wong, Z. Cheng, S. Y. Set, G. Senthil Murugan and X. Wang, ACS Photonics, 2020, 7, 2923–2940 CrossRef CAS .
- J. Hodgkinson and R. P. Tatam, Meas. Sci. Technol., 2012, 24, 12004 CrossRef .
- F. Fauzi, A. Rianjanu, I. Santoso and K. Triyana, Sens. Actuators, A, 2021, 330, 112837 CrossRef CAS .
- L. Wang, Sens. Actuators, A, 2020, 307, 111984 CrossRef CAS .
- Z. Wang, M. Yang, J. He and Q. Yang, Prog. Chem., 2015, 27, 251 CAS .
- A. Rianjanu, F. Fauzi, K. Triyana and H. S. Wasisto, ACS Appl. Nano Mater., 2021, 4, 9957–9975 CrossRef CAS .
- E. Bakker and M. Telting-Diaz, Anal. Chem., 2002, 74, 2781–2800 CrossRef CAS PubMed .
- G. W. Hunter, S. Akbar, S. Bhansali, M. Daniele, P. D. Erb, K. Johnson, C.-C. Liu, D. Miller, O. Oralkan and P. J. Hesketh, J. Electrochem. Soc., 2020, 167, 37570 CrossRef CAS .
- S. S. SebtAhmadi, M. S. Yaghmaee, B. Raissi, R. Riahifar and M. Javaheri, Sens. Actuators, B, 2019, 285, 310–316 CrossRef CAS .
- J. Zhang, G. Jiang, M. Goledzinowski, F. J. E. Comeau, K. Li, T. Cumberland, J. Lenos, P. Xu, M. Li and A. Yu, Small Methods, 2017, 1, 1700237 CrossRef .
- W. P. Jakubik, Thin Solid Films, 2011, 520, 986–993 CrossRef CAS .
- A. M. Azad, S. A. Akbar, S. G. Mhaisalkar, L. D. Birkefeld and K. S. Goto, J. Electrochem. Soc., 1992, 139, 3690 CrossRef CAS .
- B. Shen, F. Zhang, L. Jiang, X. Liu, X. Song, X. Qin and X. Li, Front. Energy Res., 2021, 9, 634321 CrossRef .
- M. Li and Y. Liu, ACM Trans. Sens. Netw., 2009, 5, 1–29 Search PubMed .
- S. Bhattacharjee, P. Roy, S. Ghosh, S. Misra and M. S. Obaidat, J. Syst. Softw., 2012, 85, 571–581 CrossRef .
- A. Baranov, D. Spirjakin, S. Akbari and A. Somov, Sens. Actuators, A, 2015, 233, 279–289 CrossRef CAS .
- A. Somov, A. Baranov, D. Spirjakin, A. Spirjakin, V. Sleptsov and R. Passerone, Sens. Actuators, A, 2013, 202, 217–225 CrossRef CAS .
- I. F. Akyildiz and E. P. Stuntebeck, Ad Hoc Netw., 2006, 4, 669–686 CrossRef .
- L. Muduli, D. P. Mishra and P. K. Jana, J. Netw. Comput. Appl., 2018, 106, 48–67 CrossRef .
- L. Dong, R. Mingyue and M. Guoying, Procedia Eng., 2017, 174, 885–889 CrossRef .
-
P. K. Mishra, S. Kumar and P. K. Mandal, in Proceedings of International Conference on Coal & Energy-Technological Advances and Future Challenges, CETAFC-2013, 2013 Search PubMed .
-
D. Harrington and E. H. Denny, Gases that Occur in Metal Mines, US Government Printing Office, 1931, vol. 347 Search PubMed .
-
M. A. Ramlu, Mine Disasters and Mine Rescue, 1991 Search PubMed .
- D. T. Gottuk, M. J. Peatross, R. J. Roby and C. L. Beyler, Fire Saf. J., 2002, 37, 381–394 CrossRef CAS .
- F. Gharagheizi, Energy Fuels, 2008, 22, 3037–3039 CrossRef CAS .
- S. Kundu, J. Zanganeh and B. Moghtaderi, J. Loss Prev. Process Ind., 2016, 40, 507–523 CrossRef CAS .
- B. Ziętek, A. Banasiewicz, R. Zimroz, J. Szrek and S. Gola, Energies, 2020, 13, 6331 CrossRef .
- P. W. Nebiker and R. E. Pleisch, Fire Saf. J., 2001, 36, 173–180 CrossRef CAS .
- G. Martinelli and M. C. Carotta, Sens. Actuators, B, 1995, 23, 157–161 CrossRef CAS .
- D. Nagai, M. Nishibori, T. Itoh, T. Kawabe, K. Sato and W. Shin, Sens. Actuators, B, 2015, 206, 488–494 CrossRef CAS .
- Y. Wang, A. Shi and F. Li, Infrared Phys. Technol., 2019, 99, 284–291 CrossRef .
- R. Ramamoorthy, P. K. Dutta and S. A. Akbar, J. Mater. Sci., 2003, 38, 4271–4282 CrossRef CAS .
- H. Wan, H. Yin, L. Lin, X. Zeng and A. J. Mason, Sens. Actuators, B, 2018, 255, 638–646 CrossRef CAS PubMed .
- Y. Wang, M. M. Tong, D. Zhang and Z. Gao, Sensors, 2010, 11, 19–31 CrossRef PubMed .
- T. Aldhafeeri, M.-K. Tran, R. Vrolyk, M. Pope and M. Fowler, Inventions, 2020, 5, 28 CrossRef .
- D. Berndt, J. Muggli, F. Wittwer, C. Langer, S. Heinrich, T. Knittel and R. Schreiner, Sens. Actuators, A, 2020, 305, 111670 CrossRef CAS .
- P. Tardy, J.-R. Coulon, C. Lucat and F. Menil, Sens. Actuators, B, 2004, 98, 63–68 CrossRef CAS .
-
M. W. Findlay, J. R. Stetter, M. T. Carter and L. Ploense, in Electrochemical Society Meeting Abstracts 233, The Electrochemical Society, Inc., 2018, p. 2417 Search PubMed .
- N. Barsan and U. Weimar, J. Phys.: Condens.Matter, 2003, 15, R813 CrossRef CAS .
- Q. Tan, L. Tang, M. Yang, C. Xue, W. Zhang, J. Liu and J. Xiong, Opt. Lasers Eng., 2015, 74, 103–108 CrossRef .
- M. Dong, C. Zheng, S. Miao, Y. Zhang, Q. Du, Y. Wang and F. K. Tittel, Sensors, 2017, 17, 2221 CrossRef PubMed .
- J. A. Nwaboh, O. Werhahn, P. Ortwein, D. Schiel and V. Ebert, Meas. Sci. Technol., 2012, 24, 15202 CrossRef .
- J. Deng, W.-L. Chen, C. Liang, W.-F. Wang, Y. Xiao, C.-P. Wang and C.-M. Shu, J. Loss Prev. Process Ind., 2021, 71, 104439 CrossRef CAS .
-
P. Shuk and R. Jantz, in 2015 9th International Conference on Sensing Technology (ICST), IEEE, 2015, pp. 12–17 Search PubMed .
- H. W. Bay, K. F. Blurton, J. M. Sedlak and A. M. Valentine, Anal. Chem., 1974, 46, 1837–1839 CrossRef CAS PubMed .
- S. M. Sedghi, Y. Mortazavi and A. Khodadadi, Sens. Actuators, B, 2010, 145, 7–12 CrossRef .
- T. Waitz, B. Becker, T. Wagner, T. Sauerwald, C.-D. Kohl and M. Tiemann, Sens. Actuators, B, 2010, 150, 788–793 CrossRef CAS .
- P. Hong, Y. Li, X. Zhang, S. Peng, R. Zhao, Y. Yang, Z. Wang, T. Zou and Y. Wang, J. Mater. Sci.: Mater. Electron., 2019, 30, 14325–14334 CrossRef CAS .
- H. Xu, J. Li, Y. Fu, W. Luo and Y. Tian, Sens. Actuators, B, 2019, 299, 126939 CrossRef CAS .
- M. Moalaghi, M. Gharesi, A. Ranjkesh and F. Hossein-Babaei, Mater. Lett., 2020, 263, 127196 CrossRef CAS .
- L. De Angelis and R. Riva, Sens. Actuators, B, 1995, 28, 25–29 CrossRef CAS .
- L. Furst, M. Feliciano, L. Frare and G. Igrejas, Sensors, 2021, 21, 7456 CrossRef CAS PubMed .
- F. S. Fateminia, Y. Mortazavi and A. A. Khodadadi, Mater. Sci. Semicond. Process., 2019, 90, 182–189 CrossRef CAS .
- G. Fedorenko, L. Oleksenko, N. Maksymovych, G. Skolyar and O. Ripko, Nanoscale Res. Lett., 2017, 12, 1–9 CrossRef CAS PubMed .
- D. Xue, P. Wang, Z. Zhang and Y. Wang, Sens. Actuators, B, 2019, 296, 126710 CrossRef CAS .
- S. Navazani, M. Hassanisadi, M. M. Eskandari and Z. Talaei, Synth. Met., 2020, 260, 116267 CrossRef CAS .
- S. Nasresfahani, M. H. Sheikhi, M. Tohidi and A. Zarifkar, Mater. Res. Bull., 2017, 89, 161–169 CrossRef CAS .
- B. Yang, Z. Zhang, C. Tian, W. Yuan, Z. Hua, S. Fan, Y. Wu and X. Tian, Sens. Actuators, B, 2020, 321, 128567 CrossRef CAS .
- Y. Wang, H. Zhang and J. Cao, Mater. Chem. Phys., 2022, 279, 125749 CrossRef CAS .
- S. Peng, P. Hong, Y. Li, X. Xing, Y. Yang, Z. Wang, T. Zou and Y. Wang, J. Mater. Sci.: Mater. Electron., 2019, 30, 3921–3932 CrossRef CAS .
- J. Shi, S. Liu, P. Zhang, N. Sui, S. Cao, T. Zhou and T. Zhang, Nanotechnology, 2021, 32, 475506 CrossRef CAS PubMed .
- T. Wagner, M. Bauer, T. Sauerwald, C.-D. Kohl and M. Tiemann, Thin Solid Films, 2011, 520, 909–912 CrossRef CAS .
- P. Siciliano, Sens. Actuators, B, 2000, 70, 153–164 CrossRef CAS .
- K. Bunpang, A. Wisitsoraat, A. Tuantranont, S. Singkammo, S. Phanichphant and C. Liewhiran, Sens. Actuators, B, 2019, 291, 177–191 CrossRef CAS .
- A. Chen, S. Bai, B. Shi, Z. Liu, D. Li and C. C. Liu, Sens. Actuators, B, 2008, 135, 7–12 CrossRef CAS .
- R. Wu, L. Tian, H. Li, H. Liu, J. Luo, X. Tian, Z. Hua, Y. Wu and S. Fan, Sens. Actuators, B, 2022, 359, 131557 CrossRef CAS .
- L. Yang, Z. Wang, X. Zhou, X. Wu, N. Han and Y. Chen, RSC Adv., 2018, 8, 24268–24275 RSC .
- L. Yao, Y. Li, Y. Ran, Y. Yang, R. Zhao, L. Su, Y. Kong, D. Ma, Y. Chen and Y. Wang, J. Alloys Compd., 2020, 826, 154063 CrossRef CAS .
- N. M. Vuong, N. M. Hieu, H. N. Hieu, H. Yi, D. Kim, Y.-S. Han and M. Kim, Sens. Actuators, B, 2014, 192, 327–333 CrossRef .
- M. Kooti, S. Keshtkar, M. Askarieh and A. Rashidi, Sens. Actuators, B, 2019, 281, 96–106 CrossRef CAS .
- N. M. Shaalan, M. Rashad and M. A. Abdel-Rahim, Mater. Sci. Semicond. Process., 2016, 56, 260–264 CrossRef CAS .
- T. Wagner, T. Sauerwald, C.-D. Kohl, T. Waitz, C. Weidmann and M. Tiemann, Thin Solid Films, 2009, 517, 6170–6175 CrossRef CAS .
- T. Waitz, T. Wagner, T. Sauerwald, C. Kohl and M. Tiemann, Adv. Funct. Mater., 2009, 19, 653–661 CrossRef CAS .
- Y. Wang, X. Sun and J. Cao, J. Alloys Compd., 2022, 895, 162557 CrossRef CAS .
- Y. Zhang, J. Cao and Y. Wang, Vacuum, 2022, 202, 111149 CrossRef CAS .
- M. B. Kgomo, K. Shingange, M. I. Nemufulwi, H. C. Swart and G. H. Mhlongo, Mater. Res. Bull., 2023, 158, 112076 CrossRef CAS .
- Y. Wang, Y. Cui, X. Meng, Z. Zhang and J. Cao, Surf. Interfaces, 2021, 24, 101110 CrossRef CAS .
- B. Zhang, Y. Wang, X. Meng, Z. Zhang and S. Mu, Mater. Chem. Phys., 2020, 250, 123027 CrossRef CAS .
- Y. Wang, X. Meng, M. Yao, G. Sun and Z. Zhang, Ceram. Int., 2019, 45, 13150–13157 CrossRef CAS .
- R. Chen, S. Luo, D. Xie, Y. Yu and L. Xiang, Chemosensors, 2022, 10, 329 CrossRef CAS .
- Y. Cai, S. Luo, R. Chen, J. Wang, J. Yu and L. Xiang, Sens. Actuators, B, 2023, 375, 132867 CrossRef CAS .
- D. Zhang, N. Yin and B. Xia, J. Mater. Sci.: Mater. Electron., 2015, 26, 5937–5945 CrossRef CAS .
- P. Bhattacharyya, P. K. Basu, H. Saha and S. Basu, Sens. Actuators, B, 2007, 124, 62–67 CrossRef CAS .
- P. Bhattacharyya, P. K. Basu, B. Mondal and H. Saha, Microelectron. Reliab., 2008, 48, 1772–1779 CrossRef CAS .
- A. Sarkar, S. Maity, C. T. Bhunia and P. P. Sahu, Superlattices Microstruct., 2017, 102, 459–469 CrossRef CAS .
- Y. Tan and Y. Lei, Ceram. Int., 2020, 46, 9936–9942 CrossRef CAS .
- D. Xue, J. Wang, Y. Wang, G. Sun, J. Cao, H. Bala and Z. Zhang, Nanomaterials, 2019, 9, 351 CrossRef CAS PubMed .
- K. Kumari and S. Ram, IEEE Sens. J., 2018, 18, 8230–8237 CAS .
- D. Zhang, H. Chang, C. Jiang, Y. Yao and Y. Zhang, Sens. Actuators, B, 2017, 252, 624–632 CrossRef CAS .
- Z. P. Tshabalala, K. Shingange, B. P. Dhonge, O. M. Ntwaeaborwa, G. H. Mhlongo and D. E. Motaung, Sens. Actuators, B, 2017, 238, 402–419 CrossRef CAS .
- B. Comert, N. Akin, M. Donmez, S. Saglam and S. Ozcelik, IEEE Sens. J., 2016, 16, 8890–8896 CAS .
- N. Lu, S. Fan, Y. Zhao, B. Yang, Z. Hua and Y. Wu, Sens. Actuators, B, 2021, 347, 130603 CrossRef CAS .
- N. M. Shaalan, M. Rashad, A. H. Moharram and M. A. Abdel-Rahim, Mater. Sci. Semicond. Process., 2016, 46, 1–5 CrossRef CAS .
- H. Roshan, M. H. Sheikhi, M. K. F. Haghighi and P. Padidar, IEEE Sens. J., 2019, 20, 2526–2532 Search PubMed .
- A. Mosahebfard, H. D. Jahromi and M. H. Sheikhi, IEEE Sens. J., 2016, 16, 4174–4179 Search PubMed .
- J. Liang, J. Liu, W. Li and M. Hu, Mater. Res. Bull., 2016, 84, 332–339 CrossRef CAS .
- S. Guo, X. Lang, H. Fan, Y. Zhu, L. Guo, Z. Liu and X. Tao, J. Electron. Mater., 2022, 51, 2156–2167 CrossRef CAS .
- Z. S. Mehrabadi, A. Ahmadpour, N. Shahtahmasebi and M. M. B. Mohagheghi, Phys. Scr., 2011, 84, 15801 CrossRef .
- A. H. Jayatissa, P. Samarasekara and G. Kun, Phys. Status Solidi, 2009, 206, 332–337 CrossRef CAS .
- J. Wang, R. Xu, Y. Xia and S. Komarneni, Ceram. Int., 2021, 47, 34437–34442 CrossRef CAS .
- J.-H. Kim, Q. T. H. Ta and J.-S. Noh, Mater. Chem. Phys., 2022, 292, 126820 CrossRef CAS .
- M. J. Bezdek, S.-X. L. Luo, K. H. Ku and T. M. Swager, Proc. Natl. Acad. Sci. U. S. A., 2021, 118, e2022515118 CrossRef CAS PubMed .
- S. Homayoonnia, A. Phani and S. Kim, ACS Sensors, 2022, 7, 3846–3856 CrossRef CAS PubMed .
- E. Lee, A. VahidMohammadi, Y. S. Yoon, M. Beidaghi and D.-J. Kim, ACS Sens., 2019, 4, 1603–1611 CrossRef CAS PubMed .
- J. M. Jones, V. A. Dupont, R. Brydson, D. J. Fullerton, N. S. Nasri, A. B. Ross and A. V. K. Westwood, Catal. Today, 2003, 81, 589–601 CrossRef CAS .
- C. K. Ryu, M. W. Ryoo, I. S. Ryu and S. K. Kang, Catal. Today, 1999, 47, 141–147 CrossRef .
- F. Bíró, C. Dücső, G. Z. Radnóczi, Z. Baji, M. Takács and I. Bársony, Sens. Actuators, B, 2017, 247, 617–625 CrossRef .
- N.-H. Park, T. Akamatsu, T. Itoh, N. Izu and W. Shin, Sensors, 2014, 14, 8350–8362 CrossRef CAS PubMed .
- C. Dücso, M. Ádám, P. Fürjes, M. Hirschfelder, S. Kulinyi and I. Bársony, Sens. Actuators, B, 2003, 95, 189–194 CrossRef .
-
L. Xu, T. Li, X. Gao, Y. Wang, R. Zheng, L. Xie and L. Lee, in SENSORS, 2010 IEEE, IEEE, 2010, pp. 391–394 Search PubMed .
- W. Jang, J.-S. Park, K.-W. Lee and Y. Roh, Micro Nano Syst. Lett., 2018, 6, 1–5 CrossRef .
- S. Y. Hsieh and K. M. Chen, J. Electrochem. Soc., 1977, 124, 1171 CrossRef CAS .
- T. Otagawa, S. Zaromb and J. R. Stetter, J. Electrochem. Soc., 1985, 132, 2951 CrossRef CAS .
- P.-A. Gross, T. Jaramillo and B. Pruitt, Anal. Chem., 2018, 90, 6102–6108 CrossRef CAS PubMed .
- Z. Wang, M. Guo, G. A. Baker, J. R. Stetter, L. Lin, A. J. Mason and X. Zeng, Analyst, 2014, 139, 5140–5147 RSC .
- B. K. Narayanan, S. A. Akbar and P. K. Dutta, Sens. Actuators, B, 2002, 87, 480–486 CrossRef CAS .
- G. Alberti, A. Carbone and R. Palombari, Sens. Actuators, B, 2001, 75, 125–128 CrossRef CAS .
- S. K. Mishra, S. N. Tripathi, V. Choudhary and B. D. Gupta, Plasmonics, 2015, 10, 1147–1157 CrossRef CAS .
- A. Krier and V. V Sherstnev, J. Phys. D Appl. Phys., 2000, 33, 101–106 CrossRef CAS .
- S. Wu, Y. Zhang, Z. Li, S. Shuang, C. Dong and M. M. F. Choi, Anal. Chim. Acta, 2009, 633, 238–243 CrossRef CAS PubMed .
- H. Xiao, J. Zhao, C. Sima, P. Lu, Y. Long, Y. Ai, W. Zhang, Y. Pan, J. Zhang and D. Liu, Photoacoustics, 2022, 26, 100353 CrossRef .
- T. Qin, Y. Niu, X. Qiao, W. Guo, C. Zhang, Z. Yang and Y. Zhang, Sens. Actuators, B, 2022, 365, 131965 CrossRef CAS .
- P. Sun, Y. Jiang, G. Xie, X. Du and J. Hu, Sens. Actuators, B, 2009, 141, 104–108 CrossRef CAS .
- W. Wang, H. Hu, X. Liu, S. He, Y. Pan, C. Zhang and C. Dong, Sensors, 2016, 16, 73 CrossRef PubMed .
- K. Choudhary, R. Saini, G. K. Upadhyay and L. P. Purohit, J. Alloys Compd., 2021, 879, 160479 CrossRef CAS .
- Y. Xia, A. Pan, Y.-Q. Su, S. Zhao, Z. Li, A. K. Davey, L. Zhao, R. Maboudian and C. Carraro, Sens. Actuators, B, 2022, 357, 131359 CrossRef CAS .
- F. Bagheri and H. Haratizadeh, Mater. Sci. Semicond. Process., 2022, 141, 106422 CrossRef CAS .
- T. Bhowmick, A. Ghosh, S. Nag and S. B. Majumder, J. Alloys Compd., 2022, 903, 163871 CrossRef CAS .
- F.-R. Juang and B.-Y. Chen, Solid-State Electron., 2020, 164, 107711 CrossRef CAS .
- S. Joshi, L. A. Jones, Y. M. Sabri, S. K. Bhargava, M. V Sunkara and S. J. Ippolito, J. Colloid Interface Sci., 2020, 558, 310–322 CrossRef PubMed .
- S. Keerthana and K. Rathnakannan, Sens. Actuators, B, 2023, 378, 133181 CrossRef CAS .
- K.-C. Hsu, T.-H. Fang, Y.-J. Hsiao and C.-A. Chan, Mater. Lett., 2020, 261, 127144 CrossRef CAS .
- P. Karthik, P. Gowthaman, M. Venkatachalam and M. Saroja, Inorg. Chem. Commun., 2020, 119, 108060 CrossRef CAS .
- C. A. Zito, T. M. Perfecto, A.-C. Dippel, D. P. Volanti and D. Koziej, ACS Appl. Mater. Interfaces, 2020, 12, 17745–17751 CrossRef CAS PubMed .
- S. Bouachma, K. Ayouz-Chebout, M. Kechouane, A. Manseri, C. Yaddadene, H. Menari and N. Gabouze, Appl. Phys. A, 2022, 128, 1–13 CrossRef .
- M. Gupta, H. F. Hawari, P. Kumar and Z. A. Burhanudin, Crystals, 2022, 12, 264 CrossRef CAS .
- M. Amarnath and K. Gurunathan, J. Alloys Compd., 2021, 857, 157584 CrossRef CAS .
- T. Suzuki, A. Sackmann, F. Lauxmann, C. Berthold, U. Weimar and N. Barsan, Sens. Actuators, B, 2020, 317, 128128 CrossRef CAS .
- P. V Shinde, N. M. Shinde, S. F. Shaikh, D. Lee, J. M. Yun, L. J. Woo, A. M. Al-Enizi, R. S. Mane and K. H. Kim, RSC Adv., 2020, 10, 17217–17227 RSC .
- K. Rathi and K. Pal, Nanotechnology, 2020, 31, 135502 CrossRef CAS PubMed .
- V. R. Naganaboina, M. Anandkumar, A. S. Deshpande and S. G. Singh, ACS Appl. Nano Mater., 2022, 5, 4524–4536 CrossRef CAS .
- S. Mulmi and V. Thangadurai, J. Electrochem. Soc., 2020, 167, 37567 CrossRef CAS .
- K. Behera, S. Pandey, A. Kadyan and S. Pandey, Sensors, 2015, 15, 30487–30503 CrossRef CAS PubMed .
- D. Fapyane and N. P. Revsbech, Proc. Natl. Acad. Sci. U. S. A., 2020, 5, 2604–2610 CAS .
- A. S. Sridhar, X. Chen, T. Glossmann, Z. Yang, Y. Xu, W. Lai and X. Zeng, Proc. Natl. Acad. Sci. U. S. A., 2023, 8, 197–206 CAS .
- C. Schwandt, R. V. Kumar and M. P. Hills, Sens. Actuators, B, 2018, 265, 27–34 CrossRef CAS .
- A. Kalyakin, A. Volkov and L. Dunyushkina, Appl. Sci., 2022, 12, 4515 CrossRef CAS .
- N. Ma, S. Ide, K. Suematsu, K. Watanabe and K. Shimanoe, ACS Appl. Mater. Interfaces, 2020, 12, 21515–21520 CrossRef CAS PubMed .
- X. Li, Z. Ye, F. Miao, B. Tao and Y. Zang, IEEE Sens. J., 2023, 23, 9093–9102 Search PubMed .
- R. Nuryadi and R. D. Mayasari, Appl. Phys. A, 2016, 122, 1–6 CrossRef CAS .
- T. Jin, F. Fujii, E. Yamada, Y. Nodasaka and M. Kinjo, J. Am. Chem. Soc., 2006, 128, 9288–9289 CrossRef CAS .
- N. J. Bareza, B. Paulillo, T. M. Slipchenko, M. Autore, I. Dolado, S. Liu, J. H. Edgar, S. Velez, L. Martin-Moreno and R. Hillenbrand, ACS Photonics, 2022, 9, 34–42 CrossRef CAS .
- M. Y. Rezk, J. Sharma and M. R. Gartia, Nanomaterials, 2020, 10, 2251 CrossRef CAS .
- C. Wang, Y. Ding, M. Li, H. Li, S. Xu, C. Li, L. Qian and B. Yang, Anal. Chim. Acta, 2022, 1190, 339264 CrossRef CAS PubMed .
- M. Berouaken, L. Talbi, R. Alkama, S. Sam, H. Menari, K. Chebout, A. Manseri, A. Boucheham and N. Gabouze, Arabian J. Sci. Eng., 2018, 43, 5957–5963 CrossRef CAS .
- B. Ersoez, K. Schmitt and J. Wöllenstein, Sens. Actuators, B, 2020, 317, 128201 CrossRef CAS .
- D. Gulevich, E. Gerasimov, A. Marikutsa, N. Khmelevsky and M. Rumyantseva, J. Alloys Compd., 2022, 893, 162297 CrossRef CAS .
- Y. Wu, J. Li, M. Lv, X. Zhang, R. Gao, C. Guo, X. Cheng, X. Zhou, Y. Xu and S. Gao, J. Hazard. Mater., 2023, 442, 130041 CrossRef CAS PubMed .
- M. O. Farea, H. A. Alhadlaq, Z. M. Alaizeri, A. A. A. Ahmed, M. O. Sallam and M. Ahamed, ACS Omega, 2022, 7, 22492–22499 CrossRef CAS PubMed .
- S. Mahajan and S. Jagtap, Appl. Mater. Today, 2020, 18, 100483 CrossRef .
- C. Qin, B. Wang, N. Wu, C. Han, C. Wu, X. Zhang, Q. Tian, S. Shen, P. Li and Y. Wang, Appl. Surf. Sci., 2020, 506, 144900 CrossRef CAS .
- L. Zhao, Y. Li, Y. Zhou, T. Wang, P. Sun, F. Liu, C. Wang, X. Yan, N. Chen and G. Lu, Sens. Actuators, B, 2022, 371, 132603 CrossRef CAS .
- S. Li, J. Pu, S. Zhu and Y. Gui, J. Hazard. Mater., 2022, 422, 126880 CrossRef CAS PubMed .
- Y. Sun, Z. Zhao, R. Zhou, P. Li, W. Zhang, K. Suematsu and J. Hu, Sens. Actuators, B, 2021, 345, 130433 CrossRef CAS .
- T. Yuan, Z. Ma, F. Nekouei, W. Zhang and J. Xu, Sens. Actuators, B, 2023, 374, 132717 CrossRef CAS .
- H. Liu, H. Yu, J. Wang, F. Xia, C. Wang and J. Xiao, Sens. Actuators, B, 2022, 352, 130981 CrossRef CAS .
- T. Hyodo, T. Goto, T. Ueda, K. Kaneyasu and Y. Shimizu, J. Electrochem. Soc., 2016, 163, B300 CrossRef CAS .
- R. J. Mortimer and A. Beech, Electrochim. Acta, 2002, 47, 3383–3387 CrossRef CAS .
- C. Chou, J. Chang and J. Zen, Electroanal. Int. J. Devoted Fundam. Pract. Asp. Electroanal., 2009, 21, 206–209 CAS .
- A. Yu, T. Kwon, C. Lee and Y. Lee, Nanomaterials, 2020, 10, 1140 CrossRef CAS PubMed .
- P. Santhosh, K. M. Manesh, A. Gopalan and K.-P. Lee, Sens. Actuators, B, 2007, 125, 92–99 CrossRef CAS .
- J.-B. He, C.-L. Chen and J.-H. Liu, Sens. Actuators, B, 2004, 99, 1–5 CrossRef CAS .
- G.-P. Jin, X. Peng, Y.-F. Ding, W.-Q. Liu and J.-M. Ye, J. Solid State Electrochem., 2009, 13, 967–973 CrossRef CAS .
- H. Yan and C.-C. Liu, Sens. Actuators, B, 1994, 17, 165–168 CrossRef CAS .
- Y. Tang, X. Liu, J. McMahan, A. Kumar, A. Khan, M. Sevilla and X. Zeng, J. Phys. Chem. B, 2019, 123, 4726–4734 CrossRef CAS PubMed .
- A. Yasuda and T. Shimidzu, React. Funct. Polym., 1999, 41, 235–243 CrossRef CAS .
- C. Phawachalotorn, O. Sanguanruang and T. Ishihara, Sens. Actuators, B, 2012, 161, 635–640 CrossRef CAS .
- C. Özbek, S. Okur, Ö. Mermer, M. Kurt, S. Sayın and M. Yılmaz, Sens. Actuators, B, 2015, 215, 464–470 CrossRef .
- H. Fukuda, K. Kasama and S. Nomura, Sens. Actuators, B, 2000, 64, 163–168 CrossRef CAS .
-
M. Vanotti, C. Theron, S. Poisson, V. Quesneau, M. Naitana, V. Soumann, S. Brandès, N. Desbois, C. Gros and T.-H. Tran-Thi, in Proceedings, MDPI, 2017, vol. 60, p. 444 Search PubMed .
- M. Proença, M. S. Rodrigues, F. Vaz and J. Borges, IEEE Sens. Lett., 2021, 5, 1–3 Search PubMed .
- M. Vistak, O. Sushynskyi, Z. Mykytyuk, O. Aksimentyeva and Y. Semenova, Sens. Actuators, A, 2015, 235, 165–170 CrossRef CAS .
- D. A. Jose, N. Sharma, R. Sakla, R. Kaushik and S. Gadiyaram, Methods, 2019, 168, 62–75 CrossRef PubMed .
- N. Singh, C. Yan and P. S. Lee, Sens. Actuators, B, 2010, 150, 19–24 CrossRef CAS .
- E. Gorbova, F. Tzorbatzoglou, C. Molochas, D. Chloros, A. Demin and P. Tsiakaras, Catalysts, 2022, 12, 1 CrossRef CAS .
- F. S. Damos, R. C. S. Luz, A. A. Tanaka and L. T. Kubota, Anal. Chim. Acta, 2010, 664, 144–150 CrossRef CAS PubMed .
- V. Thangadurai and W. Weppner, Electrochim. Acta, 2004, 49, 1577–1585 CrossRef CAS .
- R. Moos, N. Izu, F. Rettig, S. Reiß, W. Shin and I. Matsubara, Sensors, 2011, 11, 3439–3465 CrossRef PubMed .
- H. Wang, L. Chen, J. Wang, Q. Sun and Y. Zhao, Sensors, 2014, 14, 16423–16433 CrossRef PubMed .
- A. S. Mokrushin, E. P. Simonenko, N. P. Simonenko, K. T. Akkuleva, V. V Antipov, N. V Zaharova, A. A. Malygin, K. A. Bukunov, V. G. Sevastyanov and N. T. Kuznetsov, Appl. Surf. Sci., 2019, 463, 197–202 CrossRef CAS .
- W. Menesklou, H.-J. Schreiner, K. H. Härdtl and E. Ivers-Tiffée, Sens. Actuators, B, 1999, 59, 184–189 CrossRef CAS .
- J. N. Stevanović, S. P. Petrović, N. B. Tadić, K. Cvetanović, A. G. Silva, D. V. Radović and M. Sarajlić, Sensors, 2023, 23, 1313 CrossRef PubMed .
- N. Izu, N. Oh-hori, M. Itou, W. Shin, I. Matsubara and N. Murayama, Sens. Actuators, B, 2005, 108, 238–243 CrossRef CAS .
- A. Rothschild, S. J. Litzelman, H. L. Tuller, W. Menesklou, T. Schneider and E. Ivers-Tiffée, Sens. Actuators, B, 2005, 108, 223–230 CrossRef CAS .
- Y. Miyahara, K. Tsukada and H. Miyagi, J. Appl. Phys., 1988, 63, 2431–2434 CrossRef CAS .
- Y. Feng, J. Cheng, L. Zhou, X. Zhou and H. Xiang, Analyst, 2012, 137, 4885–4901 RSC .
- Z. Fan, D. Wang, P.-C. Chang, W.-Y. Tseng and J. G. Lu, Appl. Phys. Lett., 2004, 85, 5923–5925 CrossRef CAS .
- X.-Y. Dong, Y. Si, J.-S. Yang, C. Zhang, Z. Han, P. Luo, Z.-Y. Wang, S.-Q. Zang and T. C. W. Mak, Nat. Commun., 2020, 11, 3678 CrossRef CAS PubMed .
- F. Wudl, Acc. Chem. Res., 1984, 17, 227–232 CrossRef CAS .
- K. P. Goetz, D. Vermeulen, M. E. Payne, C. Kloc, L. E. McNeil and O. D. Jurchescu, J. Mater. Chem. C, 2014, 2, 3065–3076 RSC .
- A. C. Hillier and M. D. Ward, Science, 1994, 263, 1261–1264 CrossRef CAS PubMed .
- J. M. Williams, M. A. Beno, H. H. Wang, P. C. W. Leung, T. J. Emge, U. Geiser and K. D. Carlson, Acc. Chem. Res., 1985, 18, 261–267 CrossRef CAS .
- F. Favier, H. Liu and R. M. Penner, Adv. Mater., 2001, 13, 1567–1570 CrossRef CAS .
- L. Li, P. Jahanian and G. Mao, J. Phys. Chem. C, 2014, 118, 18771–18782 CrossRef CAS .
- M. Kilani, M. Ahmed, M. Mayyas, Y. Wang, K. Kalantar-Zadeh and G. Mao, Small Methods, 2023, 2201198 CrossRef CAS PubMed .
- P. Jahanian, X. Yu, M. Kilani and G. Mao, Mater. Res. Lett., 2017, 5, 569–576 CrossRef CAS .
- X. Xian, K. Yan, W. Zhou, L. Jiao, Z. Wu and Z. Liu, Nanotechnology, 2009, 20, 505204 CrossRef PubMed .
- L. Ren, X. Xian, K. Yan, L. Fu, Y. Liu, S. Chen and Z. Liu, Adv. Funct. Mater., 2010, 20, 1209–1223 CrossRef CAS .
- X. Yu, M. Kilani, A. Siddiqui and G. Mao, Adv. Mater. Technol., 2020, 5, 2000554 CrossRef CAS .
- K.-C. Ho and J.-Y. Liao, Sens. Actuators, B, 2003, 93, 370–378 CrossRef CAS .
- C. Wang, N. Wu, D. L. Jacobs, M. Xu, X. Yang and L. Zang, Chem. Commun., 2017, 53, 1132–1135 RSC .
- C. Jouve, D. Jullien and B. Remaki, Sens. Actuators, B, 1995, 28, 75–80 CrossRef CAS .
|
This journal is © The Royal Society of Chemistry 2023 |
Click here to see how this site uses Cookies. View our privacy policy here.