Issue 16, 2021

Slip formation of a high-density droplet array for nucleic acid quantification by digital LAMP with a random-access system

Abstract

Digital nucleic acid analysis (digital NAA) is an important tool for the precise quantification of nucleic acids. Various microfluidic-based approaches for digital NAA have been developed, but most methods require complex auxiliary control instruments, cumbersome device fabrication, or inconvenient preparation processes. A SlipChip is a microfluidic device that can generate and manipulate liquid partitions through simple movements of two microfluidic plates in close contact. However, the traditional SlipChip requires accurate alignment of microfeatures on different plates; therefore, the dimensions of the microwells and density of partitions can be constrained. Here, we developed a droplet array SlipChip (da-SlipChip) that can form droplets of various sizes at high density in a single slipping step. This process does not require precise overlapping microfeatures on different plates; therefore, the design flexibility and partition density can be significantly increased. We quantified SARS-CoV-2 nucleic acids extracted from the COVID-19 pseudovirus by digital loop-mediated isothermal amplification (LAMP) on a da-SlipChip with 21 696 of 0.25 nL droplets, and the results were in good agreement with those of the commercial digital PCR method of Stilla. Furthermore, we demonstrated a random-access system with a single-throughput fluorescence imager and a stackable thermal control instrument with nine independent heating modules. This random-access system with the da-SlipChip can greatly improve the total throughput and flexibility for digital isothermal nucleic acid quantification and significantly reduce the total waiting time.

Graphical abstract: Slip formation of a high-density droplet array for nucleic acid quantification by digital LAMP with a random-access system

Supplementary files

Article information

Article type
Paper
Submitted
26 Apr. 2021
Accepted
15 Jūn. 2021
First published
16 Jūn. 2021

Lab Chip, 2021,21, 3086-3093

Slip formation of a high-density droplet array for nucleic acid quantification by digital LAMP with a random-access system

W. Lyu, J. Zhang, Y. Yu, L. Xu and F. Shen, Lab Chip, 2021, 21, 3086 DOI: 10.1039/D1LC00361E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements