Dong-Hyun
Lee
a,
Min Kyung
Kim
b,
Hwanuk
Guim
c,
Seongmin
Yuk
a,
Jaeho
Choi
a,
Sungyu
Choi
a,
Gisu
Doo
a,
Dong Wook
Lee
a,
Jiwhan
Noh
*d and
Hee-Tak
Kim
*a
aDepartment of Chemical & Biomolecular Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291, Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea. E-mail: heetak.kim@kaist.ac.kr
bDepartment of Materials Science and Engineering, Korea University, Seoul, 02841, Republic of Korea
cDivision of Electron Microscopic Research, Korea Basic Science Institute, Daejeon, 34133, Republic of Korea
dKorea Institute of Machinery & Materials (KIMM), Jang-dong 171, Yuseong-gu, Daejeon, 34101, Korea. E-mail: njw733@kimm.re.kr
First published on 20th April 2020
Water management becomes a more critical issue as the power performance of polymer electrolyte membrane fuel cells (PEMFC) is progressively improved. Herein, we present a ditch-structured microporous layer (MPL) that can prevent water flooding in PEMFCs. In-plane ditch structures are carved on an MPL using a nanosecond-pulse laser ablation technique while preserving the surface porosity of the MPL. When the direction of the ditches is aligned perpendicular to the flow field direction, the power performance is significantly enhanced due to the facilitated mass transport under the rib area. The i–V polarizations and limiting current analysis suggest that not gas transport but water transport is responsible for the power performance enhancement. Compared with a perforated MPL prepared by the same technique, the ditch-structured MPL is more effective in mitigating water flooding. Diagonal and radial ditches exemplify the efficacy in making complex ditch patterns. The delicate structural engineering of the MPL enabled by laser ablation can offer a novel design platform for advanced fuel cells.
Regarding water management, the microporous layer (MPL) has a critical role. It consists of carbon and a hydrophobic binder such as PTFE and is placed in between the catalyst layer (CL) and gas diffusion layer (GDL).12–17 Due to its mesoporous structure and hydrophobic binder, the MPL facilitates water removal from the CL to the carbon paper and provides unsaturated pores for gas transport even in the event of liquid water condensation. In a PEMFC stack, the bipolar plates with a flow channel and rib compress the GDL and MPL by the stack pressure applied to it to ensure electrical contact and a tight seal. As a result, under the rib area, most of the MPL pores are saturated with water, forming a sharp boundary of water saturation at the interface between the ribs and channels,18,19 which has been regarded as an inherent problem of the current PEMFC structures. Structural modifications of the GDL and CL have been attempted to remove the water under the rib area.20–23 Naing et al. suggested a GDL with an anisotropic fiber arrangement,22 and our group reported on a patterned CL with in-plane micron channels in it.23 Both approaches enhance the power performance in the high current density regime when the direction of the in-plane mass transport is perpendicular to the flow channel direction, emphasizing the importance of the in-plane guiding of water removal.
Prevention of water flooding is also one of the crucial issues in the architecture. The simplest solution developed so far in the architecture to prevent water flooding was to make a ditch. Inspired by the guided water flow by the ditch, herein we present a ditch-structured MPL to remove the water under the rib area effectively. Fig. 1a illustrates the overall concept and structure developed in this work. Making ditch structures in the MPL has not been attempted due to the difficulty of their fabrication. However, we achieved manufacturing a well-defined ditch structure carved on the MPL using a nanosecond-pulse laser ablation technique, which is widely using for the patterning of metal surfaces.24–28 Previously, in the PEFMC field, the laser perforation technique has been used to form through-plane holes of approximately 100 μm diameter inside the GDL for water removal.29–33 Our ditch structure is different from the perforated structure in that the ditches guide not through-plane but in-plane mass transport. Furthermore, various ditch structures were simply fabricated, like drawing a line with a laser. The nanosecond-pulse was selected considering the polymer binder melting problem with the high power laser perforation technique reported in previous work.29 The nanosecond-pulse laser ablation used in this work can decompose the materials under a short-pulse duration, which is beneficial in preserving the surface pores on the ditch structure. Additionally, the nanosecond-pulse laser is more cost-effective and suitable for commercialization compared to well-known short-pulse lasers, the pulse duration of which is in the pico or femtosecond range. We demonstrate that the in-plane-ditched MPL structure can effectively mitigate water flooding under the rib area and is even more advantageous than the perforated structure.
The number of laser scans can vary the depth and width of the ditch. The ditch structure becomes deeper and broader by increasing the scan number. Typical single and triple scan ablation were compared. Fig. 2a–c show the cross-sectional and top-view SEM images for the pristine MPL (P-MPL), MPL with single ablation (D1-MPL), and MPL with triple ablation (D3-MPL), respectively. The specimens for the cross-sectional SEM measurement were prepared with epoxy filler to prevent any structural variation during the ion milling process. The cross-sectional SEM images show that the depth of the ditch was approximately 30 and 60 μm for the single and triple ablation, respectively. As compared in Fig. 2b and c, the opening of the ditch was widened with the repeated ablation. From the SEM images of the top MPL surfaces, the widened opening of the ditches with the repeated ablation was verified again. Moreover, a regular spacing of 100 μm was identified for both the single and triple ablation.
A critical issue in the laser ablation of the MPL is the possibility of blocking the surface pores due to the melting of the polymer binders during the laser ablation process. Therefore, it is vital to check the pore structure at the sidewall of the ditch. For a pulse duration of 15 ns, as shown in Fig. 2d, the pore structures are well preserved on the surface of the ditch walls, indicating that the wall surface of the ditch structure does not block the gas or water transport. However, for a pulse duration of 220 ns, the pore structures on the surfaces of the ditch walls are blocked by melted binder (Fig. 2e). The preservation of the porous structure is attributed to the use of the short-pulse laser, which decomposes the polytetrafluoroethylene (PTFE) binder material rather than melting it. This phenomenon indicates that the nanosecond pulse induces photochemical ablation rather than photothermal ablation. The two ablation modes are different in their chemical bond breakage mechanism. For the photothermal model, the energy of the absorbed laser is converted to thermal energy, causing thermal bond breakage. However, in the photochemical model, the bonds are broken in dissociative states because the absorbed photons directly excite the chromophores.34 The short-pulse laser prevents the conversion of the absorbed energy into the vibration mode, thus inducing an explosion instead of heating the solid locally.35
Because oxygen radicals form during the laser ablation, the chemical structure of the ditch surface can be varied. Fig. 3a shows the XPS spectra for the ditch surface; the carbonyl group (CO) and C–O signals were notably increased with the laser ablation, indicating that the ditch surfaces are more hydrophilic than the pristine surface. The water contact angles of the P-MPL surface were measured to be 130° in both the x and y directions, and a water droplet had a symmetrical spherical shape in its optical microscope image (Fig. 3b). However, a water droplet on the D1-MPL surface was ellipsoidal, and the contact angles were different in the measured directions as 110° (perpendicular to the ditch direction) and 120° (parallel to the ditch direction) (Fig. 3c). Although the contact angle of D1-MPL varies depending on the measured direction, it was smaller than the pristine MPL, confirming the hydrophilic property of the ditches.
The anisotropic feature of D1-MPL provides preferential water flow along the ditch direction. A water droplet was dripped onto the MPL at 60° tilted from the ground to identify the guided water transport along the ditch. For D1-MPL, the parallel and perpendicular orientation of the ditches to the ground are denoted as D1-MPL_PA and D1-MPL_PE, respectively. Movie S1 (front-view) and S2 (side-view) (ESI†) show how the water droplet moved on P-MPL, D1-MPL_PA, and D1-MPL_PE. Fig. S1a–c (ESI†) show the captured images after disposing of the water droplet for P-MPL, D1-MPL_PA, and D1-MPL_PE, respectively. For P-MPL, the water droplet quickly slid off the surface because of its hydrophobic nature (Fig. S1a, ESI†). When the direction of the gravity-driven flow and the ditch direction are perpendicular (D1-MPL_PA) the water droplet remained hanging on the surface due to the pinning of the drop in the ditches (Fig. S1b, ESI†). The ditch structure became visible under the water drop because of the refractive index contrast between the water-filled ditches and the un-ditched surfaces. On the other hand, the ditches oriented in the gravity direction (D1_MPL_PE) enabled the water drop to move down, leaving behind trapped water in the ditches (Fig. S1c, ESI†). These results indicate that the ditches readily drag water from the droplet due to their hydrophilic property.
The in-plane mass transport across the rib area during the cell operation was investigated by comparing the power performances for the parallel and perpendicular orientations of the in-plane channel to the channel direction in the bipolar plate. For the parallel alignment (D1-MPL_PA), the ditches do not connect the channel and rib areas. Thus, they may not help with water removal from the rib area. By contrast, for the perpendicular alignment (D1-MPL_PE), water can move from the rib area to the channel area along the ditches connecting the two regions.
Before analyzing the effect of the ditch structures on the mass transport, we needed to confirm that the other properties except for the mass transport property can be excluded in the analysis and thus compared the ohmic resistance (ROhm), proton conduction resistance in the CL (RCL), and electrochemical surface area (ECSA) for the P-MPL, D1-MPL_PE, and D1-MPL_PA cells. The AC impedances measured in the open-circuit condition (OCV), which represent the values for ROhm and RCL, are nearly identical among the three cells (Fig. S2a, ESI†). Because ROhm includes the contribution from electron conduction through the MEA, the invariant ROhm implies that the laser-ablated MPL provides sufficient electrical pathways despite the voids on the surface. The electrochemical surface areas (ECSA) for the MEAs were also identical as shown in the CV responses (Fig. S2b, ESI†), indicating that these cells have the same catalytic activities.
Fig. 4a shows the i–V polarization curves for P-MPL, D1-MPL_PE, and D1-MPL_PA, measured at a RH of 100% and ambient pressure with a stoichiometry of 1.2/1.5 for H2/air. Below 0.6 A cm−2, all three cells showed similar power performances, which indicates that their kinetic and ohmic polarizations were nearly identical as expected from the identical ROhm, RCL, and ECSA values. Above 0.6 A cm−2, the power performance increased in the following order: D1-MPL_PA < P-MPL < D1-MPL_PE, which means a decreased mass transport polarization in the same order. It was further confirmed by comparing the oxygen gains (cell voltage differences between O2 and air feed) (Fig. 4b). For the three cells, the oxygen gains exponentially increased with the current density due to an increase in the mass transport polarization. In line with the i–V polarization data, the oxygen gains decreased in the order of D1-MPL_PA > P-MPL > D1-MPL_PE. These results demonstrate that the ditch structure aggravates the mass transport for the parallel arrangement, whereas it facilitates the mass transport for the perpendicular arrangement. The larger transport polarizations with the parallel ditches mean that the hydrophilic voids cause severer water stagnation under the rib area at high RH operation, which was frequently observed for hydrophilic MPLs.36,37 However, the significant drop of transport polarization with the switch from the parallel to perpendicular alignment clearly shows that the ditch structure facilitates mass transport between the rib and channel areas.
The reduced transport polarization can be attributed to either gas transport or water transport or both. One of the ways to identify the gas transport property and exclude the water flooding effect is the limiting current method, which features the use of highly diluted oxygen feeds (1% O2 in N2 and 1% O2 in He) for quantifying various gas transport resistances; the current densities obtained with the diluted gases are low enough to exclude the effect of water flooding.38,39 The total gas transport resistance (γTotal) determined from the limiting current includes two contributions: the molecular diffusion resistance (γMD) from the GDL and the sum of the Knudsen and film diffusion resistances (γCL) from the CL. γMD and γCL are quantified by measuring the limiting current with the two diluted O2 balance gases. The values for γMD and γCL for the three cells are compared in Fig. 4c. The values for γCL were nearly identical for the three cells, which can be explained by the use of the same CL. Interestingly, the values for γMD were also similar among the cells despite the structural difference in the MPL. Therefore, gas transport resistance through the ditches is not a significant attribute of the mass transport polarization. The i–V polarization curves of P-MPL and D1-MPL_PE in a low relative humidity condition of 30% (Fig. S3, ESI†) also support the indifference of the gas transport; these cells show similar polarization curves because water flooding is insignificant and does not affect the performance at low RH.
According to the limiting current analysis and i–V polarization curves in the low humidity condition, it can reasonably be concluded that the enhanced mass transport with the ditch-structured MPL is attributed to the enhanced water transfer from the rib to the channel area. As shown in Fig. 4d, the hydrophilic ditches, which connect the rib and channel areas, can act as drainage ditches for liquid water, mitigating the water flooding in the rib area. However, in the parallel orientation, such in-plane water transport is not possible because the ditches do not cross the rib and channel area. Instead, the hydrophilic ditches can be a preferred site for water condensation, and the stagnant water in the ditches blocks the gas transport to the nearby catalyst layers. This result provides an important practical implication that not only the structure but also the orientation of the structure must be carefully designed.
The next question regarding the structural engineering of the MPL is the effect of the ditch depth on the power performance. We compared the ditched MPLs with various ditch depths by varying the laser scan number. With five laser scans, a perforated structure was formed, which is denoted as D5-MPL. For D5-MPL, the underlying carbon fibers of the GDL appear in the top view of the SEM image (Fig. 5a), which confirms the perforation. Fig. 5b compares the i–V polarization curves for the D1-, D3-, and D5-MPL cells at a RH of 100%. The orientations of all the samples were perpendicular to the channel direction. At a RH of 100%, the power performance of D1-MPL was higher than that of D3-MPL. However, D5-MPL, which is the perforated structure, showed a sudden voltage drop originating from severe water flooding that occurs at the massive void of the ditch structure. In terms of preventing water flooding, it is clear that the ditch structure is more effective than the perforated structure. This result can be explained in terms of the water transport through the MPL in the form of liquid or vapor.40,41 The hydrophobic MPL induces liquid water breakage into smaller droplets at the CL/MPL interface, facilitating water evaporation. Due to the lower water saturation level in the MPL, water vapor can be readily transported through the MPL. In addition, the liquid water pressure is augmented at the CL/MPL interface due to the hydrophobicity of the MPL, which is the driving force for capillary transport of liquid water through the MPL or water back flow.15 Perforated pores are known to be a preferred liquid water transport channel;42 however, the hydrophilic perforated sites in D5-MPL do not have the above-mentioned positive functions of a hydrophobic MPL, in contrast to D1- and D3-MPL, resulting in the inferior water management.
Further experimental results support that the ablated MPL exhibits better water management compared to the perforated MPL. The voltage fluctuation can be used to monitor the water flooding behaviour during a constant current operation, which reflects water accumulation and its prompt removal. Fig. 5c shows the voltage–time profiles along the three steps during the performance measurement for all cases. The D3- and D5-MPL voltage profiles were unstable during the measurement. By contrast, the D1-MPL cell showed a stable profile regardless of the current density increments, which demonstrates effective water management. Another piece of evidence for better water management is the electrochemical impedance spectroscopy (EIS) results at 1 A cm−2 shown in Fig. 5d. The diameter of the low-frequency semi-circle corresponds to the mass transport resistance, and D1-MPL has a smaller semi-circle than that of D5-MPL. The noise and unstable form of the D5-MPL semi-circle indicate accumulated water removal, which demonstrates water flooding. Therefore, the ablated MPL improves the water management compared to the perforated MPL evident by the distinct and smaller low-frequency semicircle of D1-MPL.
The merit of the laser ablation technique is to build a complex ditch structure in a simple manner, which enables systematic and delicate variation of ditch structures. To exemplify the flexibility in the ditch design, we fabricated DI-MPLs with various ditch spacings and complex diagonal and radial ditches. Fig. S4a (ESI†) shows the performances of D1-MPL with different spacings. The 100 μm spacing had a higher power performance than the 30 and 500 μm spacing because of a balance between increased hydrophilicity and an increased water removal capability with the reduced ditch spacing. However, the optimum spacing will vary depending on the intrinsic mass transport characteristic of the pristine MEA and the operating conditions. Diagonal and radial ditches were intended to drag water from a relatively-flooded region near the cathode outlet to a relatively dry part near the inlet. These patterns were successfully carved on the MPL, as shown in Fig. 6a, demonstrating the efficacy in making intricate ditch patterns. As shown in Fig. 6b, both diagonal and radial structures perform better compared to P-MPL. It indicates that the ditches connecting more and less flooded regions help to relieve water flooding. EIS analysis also supports the positive effect in reducing the mass transport resistance; the low-frequency semicircles of the diagonal and radial ditches were smaller than that of P-MPL (Fig. 6c). Even though the diagonal ditch showed a better power performance, in this case it does not mean that the diagonal structure is superior. A more sophisticated structural design can promise further improvement for every ditch structure. The examples emphasize that it is possible to create more advanced ditch structures by exploiting nanosecond-pulse laser ablation.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: 10.1039/d0ma00150c |
This journal is © The Royal Society of Chemistry 2020 |