Xiaojun Chena,
Xitong Lina,
Deyun Moa,
Xiaoqun Xiaa,
Manfeng Gonga,
Haishan Lian*a and
Yihui Luo*b
aSchool of Mechanical and Electronic Engineering, Lingnan Normal University, Zhanjiang 524048, China. E-mail: lianhs@lingnan.edu.cn
bDepartment of Mechanical & Electrical Engineering, Xiamen University, 361102, China. E-mail: 19920161151457@stu.xmu.edu.cn
First published on 13th July 2020
Bionic electronic skin with human sensory capabilities has attracted extensive research interest, which has been applied in the fields of medical health diagnosis, wearable electronics, human–computer interaction, and bionic prosthetics. Electronic skin tactile pressure sensing required high sensitivity, good resolution and fast response for sensing different pressure stimuli. In particular, there were still great challenges in the detection of wide pressure and the preparation of sensitive unit microstructures. Here, the direct-write printing of Weissenberg principle to fabricate GNPs/MWCNT filled conductive composite flexible pressure sensors on PDMS substrates was proposed. The effects of platform moving speed, microneedle rotation speed and the number of direct-write times on the line width of the pressure sensitive structure were investigated based on orthogonal experiments, and the optimal direct-write printing parameters were obtained. The performance of the S-shaped polyline pressure sensor was tested, in which the sensitivity could reached 0.164 kPa−1, and the response/recovery time was 100 ms and 100 ms respectively. The capture cases of objects of different quality and objects with flat/curved surfaces were successively demonstrated to exhibit its excellent sensitivity, stability and fast response performance. This work may paved the road for future integration of high-performance electronic skin in smart robotics and prosthetic solutions.
Previous research is devoted to using different new sensitive materials and various optimized structures to build flexible pressure sensors with similar pressure sensing functions for human skin. Until now, various flexible and stretchable physical sensors that measure and quantify electrical signals generated from human activity have been achieved based on different sensing mechanisms, in particular piezoelectricity, capacitance, and piezoresistivity10 (as shown in Table 1). According to the pressure sensing characteristics of biological skin, pressure sensing is mainly includes into low pressure induction (0–10 kPa), which can be used for human body vocalization, pulse, micro touch; medium pressure induction (10–100 kPa), which is held in hand pressure range can be used for health monitoring, plantar pressure distribution, catching.11 In order to get closer to the sensitive characteristics of biological skin, most research literature mainly improves the sensitive characteristics and response speed of flexible pressure sensors from the aspects of sensing materials and sensing mechanisms. Wang et al. developed an electronic skin flexible pressure sensor using a high-concentration silver nanowire-polyurethane elastic composite material. The sensitivity in the low-pressure region of <30 Pa and 30–70 Pa was 5.54 kPa−1 and 0.88 kPa−1, respectively.12 Lou et al. developed an electronic skin flexible tactile sensor based on graphene materials, which could quickly sense small pressure changes. The minimum detectable pressure, sensitivity and response time were 1.2 Pa, 15.6 kPa−1 and 5 ms, respectively. It showed the application potential in pulse and voice recognition.13
Transduction principles | Material/structure | Range | Sensitivity | Response time | Ref. |
---|---|---|---|---|---|
Capacitance | Fluorosilicone/air gap | 0.5–190 kPa | 0.91 kPa−1 | <1 s | Bao et al.19 |
PDMS microhairy | 0.4–5 kPa | 0.58 kPa−1 | 0.03 s | Pang et al.27 | |
Piezoresistivity | CNT/PDMS porous | 0.25–100 kPa | 0.2 kPa−1 | 1.3 Hz | Peng et al.28 |
Gold NWs | 13 Pa to 50 kPa | 1.14 kPa−1 | Not known | Guo et al.29 | |
Piezoelectricity | ZnO nanowire | 0–30 kPa | 0.37 kPa−1 | 0.15 s | Peng et al.30 |
In addition, surface microstructures provide opportunities for improving the performance of flexible pressure sensors using micromachining technology. Previous literatures have proved that microstructures such as elastic micro-pyramid arrays,14 dome-shaped structures15 and interconnected nanofiber arrays16 are effective approach to obtain high-sensitivity sensing signals. Jang et al. presented the formation of active-matrix pressure-sensitive MoS2 FET arrays for sensing wide tactile pressure ranges. This active-matrix sensor array with the outstanding spatial and temporal resolutions enabled enlarge the detectable range of pressure from 70 Pa to 5 MPa.17 Chen et al. fabricated a resistive flexible pressure sensor with graphene microstructure array, which has a sensitivity of up to 5.5 kPa−1 within <100 Pa, a detection limit of 1.5 Pa and response time of 0.2 ms.18 Bao et al. proposed a high-performance flexible pressure sensor with a microstructured rubber dielectric layer, which enables the sensor to have a maximum sensitivity of 8.4 kPa−1, a response time of <10 ms, and stability of more than 15000 cycles.19 Kim et al. developed a wearable flexible pressure sensor with a layered structure using elastic carbon nanotube microwires and its sensitivity was only 0.5 MPa−1 when the pressure was greater than 10 kPa.20 However, the pressure sensor mentioned above has a longer response time (>0.5 s) in the mid-pressure range.21 The pressure detection range and sensing performance are difficult to adapt to medium pressure sensing occasions, which limits the requirements for electronic skin to require wide pressure detection.22,23 Therefore, there is an urgent need to develop a method for manufacturing flexible pressure sensors with adjustable microstructure surfaces, making it suitable for wide pressure range detection and fast response.
The methods to fabricate electronic skin flexible pressure sensors mainly include photolithography, chemical vapor deposition (CVD), micro-contact printing, transfer, spray coating, screen printing and direct writing spray printing.24–26 Among these technologies, direct writing inkjet printing is considered to be the most promising method for the manufacture of flexible sensors because of its simple, fast and low-cost advantages, which can realize the flexible manufacturing of complex sensitive structures.
Here, a direct-write printing technology based on the Weissenberg principle is proposed for fabricating sensitive structures of flexible pressure sensors. The GNPs/MWCNT composite material is patterned and deposited on a flexible PDMS substrate as a pressure sensitive unit to realize a wide pressure range detection flexible pressure sensor. We demonstrated the application of flexible pressure sensors to capture objects of different qualities and flat/curved surfaces. The experimental results reveal the advantages of the sensors with high sensitivity and fast response. In the future, it will have huge application prospects in the fields of medical health detection, medical implants and intelligent prostheses.
Fig. 1 (a) Direct writing printing system; (b) picture of nozzle structure; (c) direct writing printing process; (d–f) various direct writing patterns. |
3D sensitive structure could be manufactured using layer-by-layer stacking based on the Weissenberg direct writing technology (Fig. 2a). The printed line appeared as a trapezoidal structure with a line width of 250 μm (bottom), and the surface microstructure was relatively rough. Transmission electron microscopy (TEM) and scanning electron microscopy (SEM) were used to characterize the microstructure of the sensitive structure of the sensor, as shown in Fig. 2b and c. TEM and SEM images show that MWCNTs were randomly dispersed in the GNPs solution, forming a bridge. The bridge part provided an effective conductive path for the pressure-sensitive structure and formed a three-dimensional conductive network. MWCNT/GNPs composites had good dispersion in sensitive structures under the Weissenberg direct writing process. The continuous rotation of the microneedles avoided the agglomeration of MWCNT/GNPs. In addition, the conductive network structure provided more transmission channels and enhances the conductive stability.
As shown in Fig. 2d–f, the microstructure features of the sensitive structure were investigated for the number of direct-writes of 20, 40 and 60 times, respectively. When the number of direct writes was 20 times, the sensitive structure exhibited a concave shape in the middle, which could be attributed to the coffee ring effect. However, when the number of direct writing was 40 and 60 times, the middle concave structure was gradually filled with the printed solution, and then the cross-section of the sensitive structure showed a trapezoidal structure.34 As the number of direct writes continues to increased, the height of the trapezoidal structure continues to increased. The printing solution easily slipped off the top, resulting in an increase in the aspect ratio of the trapezoidal structure (the area of the top decreases), which was beneficial to improve the response and stability of the pressure sensor. In addition, the rough surface morphology of the pressure-sensitive structure was conducive to reducing the contact area of the pressure surface, which could further improve the performance of the pressure sensor,35 as shown in Fig. 2g–i.
The size of the printed line width (the maximum line width at the bottom of the sensitive unit that can be observed.) determined the size of the sensitive structure during the direct printing process. Multi-parameter control was adopted to obtain a sensitive structure with suitable line width. The effects of platform moving speed, microneedle rotation speed and the number of direct-write times on the line width of the pressure sensitive unit were investigated based on orthogonal experiments, and the optimal direct-write printing parameters were obtained.
When the moving speed increased from 0.5 mm s−1, 2 mm s−1 to 4 mm s−1, the average line width decreased from 500 μm, 340 μm to 300 μm, respectively (Fig. 3a). The print line width decreases as the moving speed increased. The number of direct writes had little effect on the average line width. When the number of direct writes was 8, 20, and 40 to 60 times, the average line width remains almost unchanged, which was mainly due to the stability of the jet. Theoretically, the increase in the rotation speed of the microneedle caused the elastic recovery force of the solution to increase, resulting in an increase in the amount of liquid supplied. As shown in Fig. 3b, the average line width increased from 320 μm to 460 μm. Therefore, in order to obtain a suitable line width of the sensitive structure, the parameters of the platform moving speed and the microneedle speed needed to be compromised.
The deformation of the sensitive structure was the main source of pressure-sensitive characteristics. The ability of substrate deformation was a key factor in determining sensor performance. The deformability of the substrate could be obtained by increasing the thickness of the substrate and the microstructure of the substrate surface, where the microstructure of the substrate surface will increase the difficulty of direct write printing. Therefore, in order to improve the performance of the sensor, we investigated the relationship between the substrate thickness and the strain of the sensitive element using finite element simulation software. The finite element model of the pressure sensor was constructed, including the pressurized block, the encapsulation layer, the sensitive unit and the substrate, as shown in Fig. 4a. When a pressure of 30 kPa was applied to the pressing block, the strain distribution of the sensitive element of different substrates was obtained, as shown in Fig. 4b–f. Obviously, there was maximum deformation at the pressure edge. As the substrate thickness increased from 300 μm to 4 mm, the maximum strain of the sensitive structure increased from 0.006 to 0.025. Considering the performance and portability of the sensor, an excellent strain capability could be obtained with a substrate thickness of 500 μm.
Fig. 4 (a) Simulation model of flexible pressure sensor; (b)–(f) relationship between substrate thickness (300 μm, 500 μm, 1 mm, 2 mm, 4 mm) and strain. |
ΔR = Ra − R | (1) |
(2) |
The curves of pressure-sensitive characteristics (ΔR/R-pressure) and sensitivity were shown in Fig. 5d and e. When the applied pressure increased from 0 kPa to 75 kPa, the ΔR/R of different patterns increased with the pressure, showing a positive piezoresistive effect. As shown in the sensitive structure pattern in Fig. 5c, its ΔR/R increased from 0 to 12.17, and the positive piezoresistive effect increased with the number of bending regions. Its sensitivity had increased from 0.017 kPa−1 to 0.164 kPa−1. This multi-broken line sensitive structure was similar to the series result of multiple resistors, as shown in Fig. 5f. Generally, the more the bending number of the sensitive structure increased, the larger the area it senses. According to the finite element simulation results, the deformation of the pressure edge of the sensitive structure was the most obvious, resulting in the rapid increase of the resistance of the edge bending line. Therefore, its positive piezoresistive effect was enhanced by the cumulative effect based on the series resistance. However, the increase in the bending number of the sensitive structure will inevitably lead to an increase in the sensor area, which was not conducive to integrated manufacturing. According to the detection range and application requirements of the sensor, we needed to select a moderate bending number of the sensitive unit to obtain a good detection effect.
In order to reveal the sensitive mechanism of the pressure sensor, a sandwich pressure sensor working model was established, as shown in Fig. 6. In the absence of pressure, the sensitive structure remained in a laminated shape, and the conductive network composed of GNPs/MWCNT has good conductivity and no resistance change (Fig. 6a). As the applied pressure increases, the pressure in the tip region of the microstructure of the encapsulation layer increased, resulting in an increase in the deformation of the micro-nano structure of the sensor (Fig. 6b and c). The encapsulation layer structure is one of the factors to improve the sensitivity of the sensor. The area of deformation of the sensitive structure of the sensor increases due to the introduction of the microstructure of the encapsulation layer. This microstructure can cause greater strain on the sensitive unit, thereby enhancing the sensitivity of the sensitive unit. The 3D conductive network composed of GNPs/MWCNT was damaged by recoverability due to deformation, resulting in the resistance value continuously increasing with increasing pressure.36 Each conductive network could be considered as a variable resistor (Rn), and its resistance value depended on the contact of the conductive network (Fig. 5f). The application of external pressure that causes deformation of the sensitive structure causes the Rn between the GNPs/MWCNT network to decrease, which was the reason for the increased resistance. When the pressure was released, the conductive network returns to its original state, and the resistance returns to its original value.
Fig. 6 (a and b) The sensitive mechanism model of the flexible pressure sensor; (c) SEM of encapsulation layer microstructure. |
We demonstrated the motion capture experiments on glass bottles, batteries, and glass plates to verify the application potential of flexible pressure sensors on human prostheses, as shown in Fig. 8a–f. When grabbing a glass bottle with a weight of 19.58 g, the sensor's ΔR/R changed by ∼3; when the glass bottle was filled with 14.37 g of water, the grab action test was performed, and its ΔR/R changed by ∼7.6. This experiment demonstrates that the sensor has the ability to accurately distinguish objects of different qualities (Fig. 8a–c). Further, we tested the sensitivity of grabbing objects of similar quality on different surfaces. Compared with the flat glass plate, the sensor ΔR/R of the curved shape battery has a larger change. The possible reason was that when grabbing a curved object, the curved surface increases the strain of the sensor's sensitive unit, resulting in an increase in the resistance change. Therefore, when grasping a curved object, the sensor has a small force area and a strong pressure, resulting in a large change in resistance, so it shows higher sensitivity (Fig. 8d–f).
Fig. 8 (a–c) Motion capture applications of different quality and (d–f) different surface objects. “1” and “2” represent the process of grabbing and placing. |
When grabbing an object, the thumb pressure Fn was applied to the sensor, and the resistance value changes due to the deformation of the sensor. When the gripping action was maintained, the resistance of the sensor remained constant, indicating that the sensor has good stability. However, when the object was released, the resistance of the sensor returns to the initial value, which shows that the sensor has a quick response to the action. In addition, at the moment of grasping and placing an object, the resistance of the sensor suddenly increased due to the extra force exerted by the thumb. It shows that the sensor has excellent feedback on the pressure generated by the action details.
In this work, we connected the sensor to the digital multimeter through wires for operation testing, which interfered with the response characteristics of the pressure-sensitive structure to a certain extent. As a wearable electronic device, its wiring part needs to be removed to realize its wireless operations. Recent paper demonstrated the fully wireless operations of the pressure sensor array through integration with bluetooth and batteries, realizing the progress from wired operation to wireless integration.37,38 In the future, we will integrate the function of completely wireless operation into the flexible pressure sensor device to achieve the integration of function and structure.
This journal is © The Royal Society of Chemistry 2020 |