Time response and light yield are two of the most important features of a scintillation detector, and are mostly determined by the luminescence properties of the scintillator. Here we have investigated the radioluminescence (RL) characteristics of a single-crystalline hybrid lead halide perovskite at both room temperature and low temperature. A dual-channel single photon correlation (DCSPC) system with a vacuum chamber is employed for the measurement. A rise time faster than 100 ps and several times enhancement of the crystal scintillation performances at low temperature have been observed. These behaviors demonstrated that bulk solution-grown single crystals of hybrid lead halide perovskites (MAPbCl3 and Br-doped MAPbBr0.08Cl2.92, where MA = CH3NH3) can serve as stable scintillating materials for pulsed gamma detectors. In addition, this work provides a pathway for perovskite application and also attracts attention to investigating low-temperature scintillators.
Recently, organic–inorganic methylammonium lead halide single-crystalline materials (MAPbX3, where MA = CH3NH3, X = Cl, Br or I) with perovskite structures have been presented during the past a few years and have attracted considerable attention.9 Due to the good tolerance of optical and electronic characteristics, a lot of investigations were focusing on single crystal preparation, optical and electrical properties characterization.10,11 Furthermore, because of X-ray and gamma ray energy deposition is proportional to the atomic number of the material, MAPbX3 single crystals were reported aiming at the applications of pulsed X-ray or gamma ray detection.12,13 For ionization radiation detection, the time response of direct photon-to-current conversion pulsed gamma ray detector has reached to μs for a bulk perovskite optoelectronic device.14 The photon-to-current conversion scintillation of perovskite also has been investigated, which exhibits tunable light emission and nanosecond scintillation decay time. However, the relatively low light yield is not enough to be realized by the commercial utilization yet.
Many other scintillation semiconductor materials have shown very different behaviours at low temperatures due to the change of carrier generation and recombination dynamics.15–18 Therefore, in this work, we explored the possibility of improving the light yield by operating at low temperatures in a high-vacuum chamber, focusing on the practical application of these promising MAPbX3 materials and their compounds in scintillation detectors for pulsed gamma ray detection. Br-doped MAPbCl3 single-crystalline materials (MAPbCl3 and MAPbBr0.08Cl2.92) have been successfully synthesized at room temperature. We measured their radioluminescence (RL) temporal profiles by a dual-channel single photon correlation (DCSPC) system, with the cooler terminal in a vacuum chamber. Remarkable improvements on light yields and time resolutions (τrise < 100 ps) have been demonstrated under low temperature conditions.
The dual-channel single photon correlation (DCSPC) method needs to employ two single photon detectors to detect random single photons of the sample. The distribution of the time interval between the arrival times of the two detectors describes the autocorrelation function of the fluorescence temporal profile.21 A conventional dual-channel single photon correlation (DCSPC) system with a liquid helium cooling terminal and a vacuum chamber is employed to study the scintillation processes, which can provide low temperature down to 30 K and high measuring resolution of about 46 ps (calibrated by the Cerenkov luminescence).21 And the function of ORTEC 9327 integrates the functions of ORTEC 9306 and ORTEC 9307. Two single photon detectors were used to count random emission photons. The time interval distribution represents the autocorrelation function of the fluorescence temporal profile. A schematic diagram of the experiment is shown in Fig. 1. The MAPbX3 crystals are put on the face of the cooler terminal, in which four temperature probes are distributed. The excitation source is a radioisotope source 241Am with an activity of about 103 Bq and at the energy of 5.48 MeV. Two ultrafast micro-channel-plate photomultiplier tubes (MCP-PMT, R3809U-50) are used to collect scintillation photons, which can provide a high gain about 105 and a fast timing precision. And the two MCP-PMTs have different distances from the MAPbX3 sample, which makes sure one of the MCP-PMTs to receive only one photon at a time. The “start” and “stop” timing signals are given as T0 + t1 and T0 + t2, where T0 is the reference time from the interaction of α with the sample, while t1 and t2 are the time spans for the two light signals transmitting to MCP-PMTs, respectively. A vacuum chamber is put in the dark box to provide a stable condition for the crystals, which is also needed by the cooler. The time range of the measurement system is 50 ns, which is corresponding to the MCA channel of 2048.
In addition, we have developed X-ray fluorescence (XRF) spectroscopy measurement to test the actual molar ratio of Br to Cl.23 Fig. 3 shows a clear and strong peak locating at 11.9 keV that ascribed to Br Kα1 of the XRF spectra. The calculated molar ratio of Br to Cl is about 0.08 to 2.92, which is consistent with the above theoretically calculated results.
Luminescence time characteristics of Br-doped MAPbCl3 crystals are evaluated at room temperature. As is shown in Fig. 4, the scintillation properties of MAPbCl3 and MAPbBr0.08Cl2.92 single crystals are very different. The luminescence temporal profile of MAPbCl3 crystal indicates that the rise time is about 1.1 ns and the full width of half maximum (FWHM) is about 1.35 ns. The decay curve can be fitted with single exponential function:24
f(t) = y0 + A1exp[−(t − t0)/τ1], |
Luminescence characteristics of Br-doped MAPbCl3 crystals were measured under the same condition except the temperature of cooler terminal. The scintillation time profile of Br-doped MAPbCl3 crystals at 30 K is shown in Fig. 5. The scintillation decay time is perfectly fitted by two exponential function:
f(t) = y0 + A1exp(−t/τ1) + A2exp(−t/τ2). |
Fig. 5 Time response profile of MAPbCl3 and MAPbBr0.08Cl2.92 scintillators at low temperature of 30 K, excited with alpha particles. |
The fast time constant τ1 and slow decay time constant τ2 are 2.4 ns and 5.26 ns, respectively, which indicate that carriers recombination dynamics undergo a slower process at cooling temperature. The temperature dependence of the luminescence decay in both channels by considering the dynamics of radiative and non-radiative transition between the excited and ground states of the emission center, which correlates well with the conclusions from photoluminescence decay studies of MAPbX3 below 77 K.25 Worthwhile to be noticed that the amplitude of the scintillation profile at 30 K grows up to about three times higher than that at room temperature. The increased light yield with cooling is mainly introduced by the recombination of extra free and bound excitons due to their strong temperature dependence.26
Importantly, the rise time of the time response profile turns to be much faster at 30 K, which is over the time resolution ability of the DCSPC system. Since the time resolution of the measuring system is about 46 ps, which has been calibrated by the Cherenkov light produced with the quartz glass irradiated by gamma-rays. And the light spectrum is not the same as that in this work, there will be little disparity error resulted from optical dispersion. The error is usually less than 10 ps, because the optical path difference of 10 mm (very large for this measurement) can only cause a gap of about 33 ps. Conservatively, we believe that τrise is shorter than 100 ps according to the curve. In this case, the time performance of MAPbCl3 crystal scintillation is largely improved at low temperature, though the decay time gets slower to a tolerable level. The results reveal that MAPbCl3 crystal can be used to detect a pulsed ultra-fast gamma ray with a lower intensity.
The scintillation pulse of Br-doped MAPbBr0.08Cl2.92 crystal has also been investigated in the same condition. The time response profile of MAPbBr0.08Cl2.92 is obtained and the result is shown in Fig. 5 (red curve). Compared with the results at room temperature, the light yield exhibits an obvious enhancement, and the counting rate is high enough to make the waveform smooth. The accurate value of its rising edge time is also over the measuring resolution of the DCSPC system, and the slow component of the decay curves becomes more pronounced. The scintillation decay curve of MAPbBr0.08Cl2.92 crystals at 30 K is perfectly fitted by two exponential functions:
f(t) = y0 + A1exp(−t/τ1) + A2exp(−t/τ2). |
The fast time constant is τ1 = 0.74 ns and the slow time constant is τ2 = 8.39 ns. The FWHM of the response profile is decreased to about 683 ps, which indicates that the luminescence dynamics is dominated by the fast recombination processes due to deep level transitions and more defect centers at 30 K. However, the amplitude decreases by about three times than pure MAPbCl3 crystal at the same temperature, which is an indication of more carriers undergoing non-radiative recombination processes due to more traps. The slow component is mainly attributed to the trapping and release of charge carriers as expected.27,28 These features show that the scintillation response of MAPbBr0.08Cl2.92 crystals is faster than that of MAPbCl3 crystals, while the light yield of MAPbBr0.08Cl2.92 crystals is relatively lower than that of undoped MAPbCl3 crystals.20
In addition, as shown in Fig. 6, we have measured the RL spectra under low temperature, which was excited by 40 keV X-ray from a portable X-ray tube. The RL spectra are different when the temperature is lower and higher than 150 K. This phenomenon may be linked to the phase transition process from the orthorhombic phase to the cubic phase with the rising of temperature.29,30 While the temperature is under 150 K, three peaks have been observed. The high-energy peak centered at 387 nm is attributed to free exciton recombination emission. Emission peak located at 400 nm is mainly ascribed to near bound exciton emission.31 Low energy emission peak at 415 nm is originally from the excitonic transition.18,32 In addition, we have calculated exciton binding energy by using the relationship between the light emission intensity and temperature:33
Fig. 6 Temperature-dependent RL spectra of MAPbCl3 crystals excited with 40 keV monoenergetic X-ray. |