Xoliswa E. V. Joba,
Kerneels Jaars*a,
Pieter G. van Zyla,
Katrina MacSweenb,
Liezl Bredenkampa,
Miroslav Josipovica,
Lynwill G. Martinac,
Ville Vakkariad,
Markku Kulmalae and
Lauri Laaksoad
aAtmospheric Chemistry Research Group, Chemical Resource Beneficiation, North-West University, Potchefstroom, South Africa. E-mail: kerneels.jaars@nwu.ac.za
bAir Quality Research Division, Science and Technology Branch, Environment and Climate Change Canada, Toronto, Canada
cSouth African Weather Service c/o CSIR, Stellenbosch, South Africa
dFinnish Meteorological Institute, Helsinki, Finland
eInstitute for Atmospheric and Earth System Research, University of Helsinki, Helsinki, 00014, Finland
First published on 3rd January 2025
South Africa has been ranked among the top ten mercury (Hg) emitters globally, with emissions from coal-fired power plants being the most significant contributor. The expansion of atmospheric Hg measurement networks in southern Africa is vital within the global context but is constrained by high costs and logistics. Passive air samplers were developed to address these issues and expand atmospheric monitoring networks. A commercially available passive sampler widely used for atmospheric Hg monitoring is the Mercury Passive Air Sampler (MerPAS®). Therefore, this study aimed to statistically evaluate the performance of these samplers in the unique South African environment by comparing Hg concentrations determined with MerPAS® with active in situ atmospheric Hg measurements conducted in this region. Measurements were conducted from June 2021 to September 2022 at the Welgegund atmospheric monitoring station, considered one of Africa's most comprehensively equipped atmospheric measurement sites. Hg concentrations measured with MerPAS® were derived for different sampling rates (SR), i.e. the original SR (OSR) provided by the supplier and an adjusted original SR (AOSR) derived using the OSR with adjustments for mean temperature and wind speed. Statistical analyses, including Kruskal–Wallis, Mann–Whitney U, Bland–Altman, and Spearman correlation tests, were used to assess the performance of MerPAS®. The OSR overestimated Hg concentrations by 16%, while the AOSR reduced this overestimation to 10%, improving alignment with active sampling data. The Mean Normalized Difference (MND) also decreased from 17.4% with OSR to 12.7% with AOSR, indicating greater accuracy. Spearman correlation analysis showed moderate agreement between passive and active sampling, with correlation coefficients of 0.39 for OSR and 0.58 for AOSR, supporting the improved comparability of AOSR. Seasonal patterns were consistent across both methods, with elevated Hg levels observed in winter due to atmospheric inversions and increased emissions. Despite a slight positive bias, the Bland–Altman analysis further confirmed good reliability between the AOSR and active measurements. This study demonstrates that MerPAS®, when calibrated for local environmental conditions, provides an accurate, cost-effective alternative for Hg monitoring, offering a feasible solution for expanding networks in regions with limited resources. By enabling broader and more accessible atmospheric Hg data collection, MerPAS® can support critical environmental policies, such as the Minamata Convention, and deepen scientific understanding of Hg dynamics in under-monitored areas like southern Africa. These findings lay the groundwork for enhancing global Hg monitoring, contributing essential insights into regional pollution and atmospheric processes across diverse environments.
Environmental significanceSouth Africa is a top global emitter of mercury (Hg), primarily from coal-fired power plants. Expanding atmospheric Hg monitoring networks in southern Africa is critical but is hindered by high costs and logistical challenges. This study statistically evaluated the performance of a commercially available passive air sampler, the Mercury Passive Air Sampler (MerPAS®), by comparing its Hg concentrations to active in situ atmospheric Hg measurements at a regional background site in South Africa from June 2021 to September 2022. Statistical analyses revealed that while MerPAS® slightly overestimated Hg concentrations, adjustments for environmental factors improved its accuracy and alignment with active measurements. These findings highlight MerPAS® as a cost-effective solution to expand Hg monitoring networks in resource-limited regions, supporting global and regional efforts to mitigate Hg pollution under the Minamata Convention. |
Given that the atmosphere represents the primary pathway for the global distribution of Hg,6–8 monitoring atmospheric Hg is essential in achieving the above-mentioned objectives. Existing atmospheric Hg monitoring networks, such as the Global Mercury Observation System (GMOS), the Atmospheric Monitoring Network (AMNet), and the Environment and Climate Change Canada Atmospheric Mercury Monitoring Network (ECCC-AMM), have greatly improved our understanding of atmospheric Hg,9 while it also contributed to the development of global atmospheric dispersion models10 such as GEOS-Chem, GLEMOS, GEM-MACH-Hg and ECHMERITRADM.11 However, the spatial coverage of these networks is limited, especially for the southern hemisphere and Africa,9 which leads to large gaps in understanding atmospheric Hg cycling. Therefore, it is globally acknowledged that further network expansion is pivotal.12,13
The Global Atmospheric Watch (GAW) station at Cape Point (CPT), South Africa, represents the longest-running site for Hg monitoring in the southern hemisphere.14–19 These studies highlighted complex transport and deposition dynamics, with biomass burning and shipping routes identified as significant contributors to atmospheric Hg. Bieser et al.20 also emphasized the role of oceanic sources in the southern hemisphere Hg budget, suggesting that air–sea exchange may compensate for reductions in atmospheric emissions from the Minamata Convention.
While the above mentioned site provides a valuable long-term coastal baseline, its location limits insights into Hg levels in South Africa's industrialized inland regions. Despite the region's notable industrial activities and high air pollution levels, research on Hg levels in South Africa's interior remains limited. Recent short-term studies in the Highveld Priority Area21,22 have provided initial Hg concentration data, yet comprehensive, long-term monitoring efforts in the region are lacking. Recognizing this gap, the South African Mercury Network (SAMNet) has been established to create a broader monitoring network, targeting both industrial and background locations. This initiative aims to yield spatially representative Hg data, offering a more comprehensive perspective on regional Hg dynamics.
However, the expansion of SAMNet is constrained by high costs, logistics (e.g. availability of electricity and specialized materials), as well as underdeveloped capacity and expertise (e.g. technical training). Addressing this deficiency in atmospheric Hg network coverage in South Africa is crucial to our global understanding of atmospheric Hg distribution and assessment of its impacts. In order to overcome these limitations in spatial coverage of atmospheric Hg monitoring, an alternative approach has been followed through the development of passive air samplers (PAS), which has the potential to significantly improve the spatial resolution of atmospheric Hg measurements.12,23,24 These passive samplers offer a range of benefits, which include lower costs and no electricity requirements and can be deployed in large numbers, especially throughout South Africa. However, PAS does have certain limitations. One deficiency is the relatively longer collection time required to accumulate sufficient analyte, which limits the temporal resolution of the data obtained. Additionally, measurement of other than gaseous elemental mercury (GEM), such as gaseous oxidized mercury (GOM) and particulate-bound mercury (PBM) with PAS, remains challenging.
In passive sampling, the gaseous analyte diffuses through a barrier into a chamber at a known rate into the specially designed sampler. The analyte is trapped inside the chamber on a sorbent material, which is analyzed after deployment. One commercially available PAS widely used in Hg monitoring is the Mercury Passive Air Sampler (MerPAS®), developed by the University of Toronto and later commercialized by Tekran®. While MerPAS® relies on diffusion, other PAS designs, such as the two-bowl PUF-PAS, rely on a flow-through approach using airflow.25 This sampler has a unique design that utilizes sulphur-impregnated activated carbon as the sorbent material and incorporates a diffusive barrier to control the sampling rate. It also features a protective shield, allowing deployment in outdoor environments for extended periods. The MerPAS® method has been evaluated globally at atmospheric monitoring sites in different environments with variable atmospheric Hg concentrations.26,27 Recently, Naccarato et al.26 showed that MerPAS® is currently the best available passive sampler for GEM concentration monitoring, while McLagan et al.28 indicated that the precision of these samplers is 3.6 ± 3.0%, with an overall uncertainty of 8.7 ± 5.7% when compared to active measurements of several PAS globally deployed. However, the performance of these samplers has not been evaluated within South Africa in any of these studies.
Therefore, this study aims to evaluate the accuracy, precision and reliability of MerPAS® statistically, specifically in the unique South African environment, by comparing Hg concentrations determined with these samplers with well-established active in situ atmospheric Hg measurements conducted in this region. MerPAS® was deployed at a comprehensively equipped regional atmospheric monitoring station in the South African interior, which provides a reliable benchmark for comparison. Measurements were conducted through the recently established South African Mercury Network (SAMNet), which aims to expand the spatial resolution of atmospheric Hg measurements conducted in this region. The use of MerPAS® is crucial to the successful rollout and establishment of this expanded atmospheric Hg monitoring network.
MerPAS® utilized in this study were prepared and shipped directly from the manufacturer (Tekran® Instruments cooperation). The samplers were sealed tightly with vinyl electrical tape, individually placed into zip-lock plastic bags, and shipped and stored in sturdy foam-lined aluminium or hard plastic cases. At Welgegund, three MerPAS® were removed from the plastic bags. The solid lids of two samplers were removed and replaced with black mesh screens, with their top facing into the samplers. The third MerPAS® was used as a blank to monitor contamination during the sampler assembly, handling, transport, and storage. A field blank was used for every deployment and was exposed for about four weeks, with the last blank exposed for almost 14 weeks. This was done to evaluate if the field blank contamination increased with deployment duration, and it was found that blank levels were much lower in the longer exposure time. Duplicate MerPAS® were deployed monthly from June 2021 to September 2022. These samplers were attached to a mounting bracket 4 m above ground level, with the open side of the samplers facing downward. After exposure, MerPAS® was removed from the mounting brackets, capped, sealed with polytetrafluoroethylene tape, again placed in plastic bags, and shipped in the aforementioned plastic cases to the Environment and Climate Change, Canada for analysis.
The MerPAS® were analyzed with a Direct Mercury Analyzer (DMA-80; Milestone Inc., Shelton, CT, USA), which determines the total Hg mass absorbed by the passive sampler by thermal desorption and amalgamation. The analysis followed the modified US EPA method 7473, which is commonly used to determine Hg in complex matrices such as fish, sediment, and coal.41–43 Prior to analysis, the stainless-steel cartridges of the MerPAS® containing the carbon sorbent were removed and separated into two sample aliquots. The two samples are then summed preceding analysis to determine the total Hg collected by the MerPAS®. Individual samples aliquots are coated in ∼0.5 g of Sodium Carbonate (Na2CO3). Approximately 5 g Na2CO3 is also used to modify the catalyst tube. The Na2CO3 is used to limit the impact of the high sulphur content of the carbon sorbent that can cause poisoning of the catalyst and minimize analytical artefacts.44 The samples were then thermally decomposed at 570 °C within the catalyst tube, releasing Hg from the carbon sorbent. Oxygen is then used to pull the released Hg through the catalyst and trapping all realized Hg on the gold amalgamator. The amalgamator is then heated to 900 °C to release Hg, which is then subsequently quantified by atomic absorption spectroscopy at a wavelength of 253.7 nm. Instrument recovery was tested every 15 to 20 samplers using 10 ng liquid Hg standards, and precision was tested every 30 samples using standard reference material, SRM NIST 2685c bituminous carbon 5% sulfur (NIST reported concentration 149.4 ± 4.5 ng g−1). The average SRM NIST 2685C concentration was 146.8 ng g−1 (SD 11.11, n = 7) and a recovery of 98.3%. 10 ng Hg liquid standard averages 10.31 ng (SD 0.73, n = 13), with an average recovery of 103.1%. The DMA undergoes a full calibration if the recovery tests drift beyond 5% every time the catalyst is replaced. Calibration curves are established using liquid Hg standards of increasing concentrations on clean HGR-AC.
Data coverage over the 14 months sampling period was high, with the Tekran® 2537X capturing GEM measurements consistently. Weekly site visits, automated 24 hours calibrations, and an MFC minimized data interruptions, ensuring the reliability of the active dataset. Fig. S1† provides a visual summary of the percentage of data successfully captured, offering transparency in data continuity and supporting the comparability between active and passive sampling methods.
(1) |
(2) |
Table S1† summarises all these parameters utilized in calculating Hg concentrations with MerPAS®. On average, blank contamination in the MerPAS® deployed at Welgegund was 10% (ranging between 7% and 14%, Table S1†) of the amount quantified in an exposed sampler, which is in the same range as determined in other studies.26,46
We first checked the concentrations obtained with the active in situ measurement and those derived from MerPAS® with the OSR and AOSR for outliers using the identify outliers function of the rstatix package. Outliers were identified but were not extreme. As a result, these outliers were kept in the data since they were detected for measurements taken in July, which is the middle of winter when Hg concentrations are usually high for the South African interior.21,30,32,33
To test for differences between concentrations derived from the active in situ measurement and those derived from MerPAS® using four SRs, a one-way ANOVA was conducted using IBM SPSS version 29 for Windows. Standardized residuals were saved so that the compliance with the requirements for ANOVA (normally distributed residuals, homogeneity of variance) could be tested using the Kolmogorov–Smirnov one-sample and Levene's test. These tests revealed that the requirements of equal variance were met, but not normality, even when the dataset was log10(x) transformed. Therefore, non-parametric tests were performed since only one requirement was met. The Mann–Whitney U test was used to compare two methods, and the Kruskal–Wallis test was used to compare more than two. At the same time, we used epsilon squared (ε2) to assess the effect size.
Spearman's correlation coefficient (ρ(rho)) was employed to assess the linear relationship between concentrations obtained from the active in situ measurement and those derived from MerPAS® using the OSR and AOSR. The general guidelines we used for interpreting the p-value, ρ, r and ε2 are provided in ESI Table S2.†53 In addition, exploratory, descriptive statistic calculations (mean, median, minimum, maximum, and standard deviation) were performed on the dataset to gain a general overview of variations in monthly average concentrations. For all statistical significance tests, we assume the null hypothesis to indicate a similar distribution while the alternate hypothesis suggests that statistically significant differences exist in the compared distributions. We use the significance level, i.e. alpha as 0.05, to accept or reject the null hypothesis.
Furthermore, we use the Bland–Altman analysis to identify any systematic biases or trends between the active in situ and any specific MerPAS® with the OSR and AOSR and determine the magnitude and direction of the differences between the methods. This statistical analysis provides valuable insights concerning measurement methods' accuracy, precision, and agreement. We used the eirasagree package in R, developed by Silveira et al.,54 to create a Bland–Altman plot and analyze our data to determine the agreement between concentrations from the active in situ measurement and those derived from MerPAS® using four SRs.
The mean normalized difference (MND) and relative standard deviation (RSD) were also calculated for the datasets obtained from MerPAS® with the four SRs in relation to the active in situ measurements. MND and RSD also reflect the accuracy and variability in datasets. The MND is calculated as follows:
(3) |
To put these findings into context, Fig. S2† compares the mean blank concentration for Hg in this study with those reported in other studies utilizing passive sampling for mercury. It is worth noting that achieving blank levels below or around 0.5 ng g−1 is only possible when there is minimal transportation and limited storage time after sampling.26,27,37,38,46 Studies involving transportation over regional distances, extended sampler storage, and sampling at Hg-contaminated sites have indicated slightly higher blank levels ranging from 0.5 ng g−1 to 2 ng g−1.39,55
However, there have been instances where field blank levels have exceeded 3 ng g−1. Examples include a study involving 20 global sampling sites,28 measurements conducted at a gold mine in Ghana,56 and a site in New Zealand.57 Moreover, studies conducted in extreme and remote environments, such as the Antarctic plateau, Amsterdam Island, and La Réunion, have also reported blank levels higher than 3 ng g−1.46
Other researchers have reported varying levels of precision. Quant et al.55 reported a precision of 7.5%, Skov et al.58 reported 7.7%, Zhang et al.59 reported 10%, Hoang et al.46 reported a range of 8–39%, and Snow et al.56 reported a range of 1.1–17.5% and 0.9–5.7% for low and high concentration conditions, respectively. Cho et al.60 observed replicate precision of GEM concentrations in different groups over different deployment times, ranging from 8.2% to 1.8%.
The relatively poor replicate precision observed in the present study can be attributed to various factors. These include the blank correction, which represents a relatively large fraction of the sequestered amount of Hg, as well as the relatively high variability in the field blank levels. Additionally, poorly sealed samplers, recording deployment time and date errors, and losses during analysis (such as catalyst failure) could have contributed to the observed results.
Month | Active in situ | MerPAS® OSR | MerPAS® AOSR |
---|---|---|---|
06/2021 | 1.82 | 1.81 | 1.83 |
07/2021 | 2.40 | 3.12 | 3.19 |
08/2021 | 1.65 | 2.32 | 2.22 |
09/2021 | 1.32 | 1.93 | 1.74 |
10/2021 | 1.41 | 1.93 | 1.74 |
11/2021 | 1.59 | 2.16 | 1.89 |
12/2021 | 1.33 | 1.48 | 1.25 |
01/2022 | 1.75 | 1.78 | 1.63 |
02/2022 | 1.53 | 1.66 | 1.52 |
03/2022 | 1.92 | 2.18 | 2.06 |
04/2022 | 1.64 | 1.73 | 1.67 |
05/2022 | 2.02 | 2.06 | 2.02 |
06/2022 | 1.77 | 1.87 | 1.86 |
07/2022 | 1.77 | 1.71 | 1.67 |
08/2022 | 1.52 | 1.82 | 1.72 |
Mean | 1.70 | 1.97 | 1.87 |
Median | 1.65 | 1.87 | 1.74 |
SD | 0.28 | 0.39 | 0.43 |
Min | 1.32 | 1.48 | 1.25 |
Max | 2.40 | 3.12 | 3.19 |
The Kruskal–Wallis test indicated no statistically significant difference between Hg concentrations obtained from the active in situ and those derived from MerPAS® OSR and AOSR (χ2 (2, N = 45) = 5.50, p = 0.06). Although the p-value approached significance (p < 0.05), it remained slightly above this threshold, suggesting that observed variations likely reflect random differences rather than systematic ones between sampling methods. However, the effect size (ε2 = 0.12) indicates that approximately 12% of the variability in Hg concentrations could be attributable to differences in sampling approach. While this effect is modest, the broad 95% confidence interval (0.02–1.00) reflects substantial uncertainty, highlighting the importance of further consideration of environmental and logistical factors impacting field measurements.
Further analysis using the Mann–Whitney U test reveals method-specific differences, with the OSR sampler showing a statistically significant 16% overestimation relative to active in situ measurement (W = 56.00, p = 0.020; r = −0.50, 95% CI [−0.75, −0.13]). In contrast, the AOSR showed a reduced, statistically nonsignificant overestimation of approximately 10% (W = 82.50, p = 0.221; r = −0.27, 95% CI [−0.60, 0.15]). The MND values are consistent with these findings, with the OSR yielding an MND of 17.42 ± 16.06%, while AOSR showed an improved MND of 12.65% ± 12.53%, suggesting that the AOSR better approximates the active in situ data. Collectively, these results indicate that while MerPAS® samplers provide estimates close to Tekran measurements, slight overestimations are present, particularly in challenging field conditions.
Environmental and logistical factors likely drive these differences. Deploying PAS at high-altitude sites such as Welgegund (1480 m asl) poses unique challenges due to lower atmospheric pressure. At higher elevations, reduced pressure enhances diffusion rates by increasing diffusion coefficients, yet it also decreases air density, resulting in less air mass per unit volume.61,62 Although these effects theoretically counterbalance each other, the 16% overestimation of Hg concentrations at Welgegund points to a net increase in SR due to enhanced diffusion, aligning with similar findings from other high-altitude sites, such as Mt. Lulin and Mauna Loa. At these locations, passive samplers systematically overestimated Hg concentrations when compared to active in situ measurements (McLagan et al.28). Adjustments to the SR with wind speed and temperature appeared to mitigate these altitude-related influences, though variability persists.
Additional logistical constraints, such as this study's relative standard deviation (RSD%) for MerPAS® samplers, was 14 ± 13%, higher than values reported in comparable studies. This elevated RSD% likely results from blank correction variability, deployment inconsistencies, and Hg content in blanks, which underscore the need for rigorous control in field protocols.
Another factor is the inherent uncertainty in active in situ measurements, estimated at 5–10%.63,64 Although the active in situ in this study operated with a mass-flow controller to reduce pressure-induced variability, these intrinsic uncertainties likely propagated into comparisons. For example, the AOSR's 10% overestimation aligns with the upper range of active in situ uncertainty, suggesting that observed discrepancies reflect expected measurement variability rather than systematic bias.
Dynamic atmospheric conditions at Welgegund add another layer of variability. Shifts in air masses driven by natural and anthropogenic factors can lead to short-term fluctuations in Hg concentrations,65,66 which may explain persistent overestimations in passive samplers despite AOSR adjustments. Comparable observations at the Maïdo Observatory (2160 m asl) showed that passive samplers overestimated Hg by 31% compared to Tekran, likely due to similar environmental dynamics.46 While these results suggest that the MerPAS® can provide comparable concentration estimates to the Tekran 2537X under the conditions of this study, a closer examination of several key factors is warranted to understand the implications of this comparison fully. Specifically, the challenges associated with sampling at high altitudes, the inherent uncertainties in active in situ measurements, and the potential propagation of these uncertainties into passive sampling calibration must be thoroughly addressed.
To further substantiate the earlier findings, Fig. 3 depicts the Spearman correlation of active in situ measurement against MerPAS® OSR and AOSR in this study and PAS-derived Hg concentrations using McLagan et al.28 recalibrated SR and adjusted SR. The figure also includes inferential statistics, such as effect size estimates, uncertainty, and pairwise comparisons. The dotted lines represent trend lines for each dataset, while the dashed dark teal line indicates the 1:1 relationship. Markers are coloured based on site type: red for urban sites, blue for rural sites, purple for high-altitude sites, green for northern/Arctic sites, and black for Welgegund. The fitted relationship from McLagan et al.28 combines all data and shows that the data points and the linear regression lines (dashed black for Welgegund and red for global sites) are positioned either above or below the 1:1 line, supporting the observation that MerPAS® tends to overestimate Hg concentrations.
It is important to emphasize that the study by McLagan et al.28 used the University of Toronto (UofT)-based mercury PAS, which differs from the commercialized MerPAS®. Additionally, the UofT PAS and MerPAS® operate with different sampling rates (SRs)-0.111 m3 per day for MerPAS® versus 0.135 m3 per day for the UofT PAS. Consequently, any comparisons made between the UofT PAS data from McLagan et al.28 and this study using MerPAS® must be interpreted cautiously, as they are not directly comparable. Here, we use the PAS data to provide context and demonstrate where the results of this study align with the broader dataset.
Notably, even though Welgegund is a high-altitude site, its data are not closely aligned with the high-altitude sites from the McLagan et al.28 study. This difference highlights the unique atmospheric conditions and pollution influences at Welgegund, which is situated in a region subject to frequent pollution plumes from South Africa's industrial hubs. These factors likely play a significant role in the observed differences, and they underscore the distinct pollution regime at Welgegund compared to other high-altitude sites in McLagan et al.28
The correlation between passive and active gaseous Hg concentrations improves when adjusted sampling rates (SRs) are applied, as indicated by the reported Spearman correlation (ρ) values, which range from 0.39 to 0.58, representing moderate to significant positive correlations. However, the correlation between Active and OSR was not statistically significant (p > 0.05), while it was significant for concentrations derived from adjusted SRs (p < 0.05). These p-values suggest that the correlation between Active and OSR may be due to chance, but the correlations using adjusted SRs are more robust.
It is crucial to consider the wide confidence interval (95% CI) for both active and passive gaseous Hg concentrations across all graphs, ranging from −0.20 to 0.81. This indicates that the results are consistent with both negligible (ρ = −0.20) and significant (ρ = 0.81) relationships, making it challenging to draw definitive conclusions about the strength of the correlation.
Finally, the data from Welgegund cluster around the urban, rural, and northern/Arctic data points from McLagan et al.,28 reinforcing that, while the site is classified as high-altitude, its regional atmospheric characteristics and proximity to significant anthropogenic pollution sources lead to a distinct pollution profile compared to McLagan's high-altitude sites. Welgegund frequently encounters pollution plumes from industrial hubs, including the Johannesburg-Pretoria megacity, the Vaal Triangle, the western Bushveld Complex, and the Mpumalanga Highveld. In addition, relatively clean air masses from the north-northwest to south-southwest sectors are also measured at the site, but their influence is less frequent compared to the dominant industrial emissions.
Fig. 4 Similarity of accuracy (top panel), precision (middle panel), and reliability (bottom panel) for active in situ vs. MerPAS® OSR obtained with 5 × 103 bootstrap iterations. |
Fig. 5 Similarity of accuracy (top panel), precision (middle panel), and reliability (bottom panel) for active in situ vs. MerPAS® AOSR obtained with 5 × 103 bootstrap iterations. |
Examining the accuracy plots (top panel), the (0,0) point representing perfect agreement falls outside the 95% confidence intervals for both MerPAS® OSR and MerPAS® AOSR. For MerPAS® OSR, the 95% CI was [0.1079, 0.4257], while for MerPAS® AOSR, it was [0.0241, 0.3202]. This indicates the MerPAS® OSR and MerPAS® AOSR exhibit statistically significant positive biases, overestimating the Hg concentrations compared to the active in situ.
The precision tests (middle panel) for both MerPAS® OSR and MerPAS® AOSR, the horizontal precision (x, 0) lines fell outside the 95% confidence bands, rejecting the null hypothesis of precision equivalence. This suggests the precision of the MerPAS® derived concentration is not statistically comparable to active in situ measured concentration.
In contrast, the reliability tests (bottom panel) showed more promising results. For both MerPAS® OSR and MerPAS® AOSR, the bisector line representing perfect agreement was within the 95% confidence bands, supporting the reliability between these methods and active in situ.
Overall, the analyses presented in Fig. 4 and 5 provide a mixed picture regarding the equivalence of the active in situ compared to the MerPAS® OSR and MerPAS® AOSR. While the reliability tests suggest acceptable agreement, the accuracy and precision evaluations revealed statistically significant biases and a lack of precision equivalence. These findings indicate the MerPAS® approach, when using OSR and AOSR to derive concentrations, may not be suitable replacement for the active in situ Hg measurement technique, at least based on the data shown. Further investigations would be needed to fully establish the comparability and interchangeability of these methods. Researchers and practitioners should consider the trade-offs carefully when selecting the appropriate Hg measurement approach for their applications.
Fig. 6 Comparison of the monthly average Hg concentrations determined with MerPAS® AOSR (grey) and active in situ (black) during the sampling period. |
Various statistical tests were conducted to analyze differences between the passive and active sampling techniques, including the Kruskal–Wallis test, Mann–Whitney U test, Spearman correlation, and Bland–Altman analysis. Results indicated that Hg concentrations obtained using MerPAS® with the OSR and AOSR generally showed higher values compared to active in situ measurements. However, using the AOSR helped reduce some of the uncertainty associated with MerPAS® measurements, as reflected in the Mean Normalized Difference (MND) values. The findings in this study indicate a need for adjusted sampling rates like the AOSR to improve MerPAS®'s accuracy when compared to active in situ measurements.
Further statistical analyses revealed no statistically significant differences in Hg concentrations obtained from the two sampling techniques. The Mann–Whitney U test clarified the extent of overestimating Hg levels, while the Spearman correlation supported observations that MerPAS® tends to overestimate Hg levels. The Bland–Altman analysis confirmed reliability, while the accuracy and precision evaluations were not statistically comparable to active in situ measurements.
While this statistical analysis revealed improved accuracy with AOSR, it did not consider the impact of various atmospheric factors, such as Hg emissions sources, deposition processes, long-range transport, and chemical transformations, on Hg levels measured by MerPAS®. The dataset used was relatively small, which posed specific challenges in the statistical analysis of Hg concentrations. These challenges included: (1) limited statistical power, making it difficult to detect minor yet potentially meaningful differences in Hg levels; (2) higher uncertainty in statistical estimates, affecting the precision and reliability of conclusions; (3) reduced generalizability of findings, limiting the study's representation of Hg variability across different environmental conditions and timeframes; and (4) increased sensitivity of results to small changes in the dataset or analysis approach, which may reduce reproducibility.
Based on our findings, we recommend using AOSR for Hg monitoring at sites in southern Africa where MerPAS® is deployed. Nonetheless, it is important to acknowledge these limitations and the need for further research. Larger datasets and a more in-depth investigation of Hg concentrations' mechanisms would improve our understanding of seasonal patterns and factors affecting passive sampling measurements.
In conclusion, this study contributes valuable insights into atmospheric Hg monitoring by statistically evaluating passive and active sampling techniques. Future studies, ideally with larger datasets and a stronger focus on underlying environmental mechanisms, can refine our understanding and enhance the accuracy of Hg monitoring in diverse field conditions.
Footnote |
† Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d4ea00071d |
This journal is © The Royal Society of Chemistry 2025 |